Инструкция по эксплуатации Follett, модель U155XR400A/W

Производитель: Follett
Размер: 558.48 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


3. Connect syrup line #1 to rinse tank, pressurize tank to 20-50 psi, and dispense 3 gallons (11L) into a suitable container from valve #1. 4. Repeat this cleaning and rinsing for all syrup lines. 5. Remove diffusers and nozzles from valves, soak in cleaning solution, rinse well and reinstall. Sanitizing beverage lines Prepare 6 gallons (23L) of sanitizing Solution B. Fill a clean product tank with this solution. 1. Connect one tank to syrup line #1. Dispense 1/2 gallon (2L) from valve #1. 2. Repeat for all remaining syrup lines, allowing sanitizing solution to remain in all circuit lines for 15 minutes. 3. Connect a clean, empty tank (pressurized to 50 psi) to each syrup line and blow out sanitizer by operating each valve. 4. Remove diffusers and nozzles from valves, soak in sanitizing solution for 15 minutes, rinse well and reinstall. 5. Reconnect all lines and dispense product through valves to purge any remaining sanitizer. 11 Recommended daily dispenser cleaning 1. Remove all debris from drain pan. 2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear. Recommended weekly dispenser cleaning 1. Remove drain pan and grille and wash with Solution A. Rinse thoroughly. 2. Remove nozzles and diffusers from valves, soak for at least 10 minutes in cleaning Solution A, rinse, sanitize with Solution B and reinstall. 3. Pour a solution of one cup (8oz/237ml) household bleach mixed with one gallon (3.8L) hot water into drain pan to help prevent algae growth in drain lines. Recommended quarterly dispenser cleaning 1. Remove top from dispenser and turn power switch to OFF position. 2. Remove ice from storage area. 3. Remove dispense chute cover, chute, auger motor assembly, auger and auger tube (see Service section). 4. Remove drain pan, grille and dispense wheel (see Service section). 5. Clean all components and bin storage area with Solution A, rinse thoroughly with clear water and sanitize with Solution B. 6. Remove nozzles and diffusers from valves, soak for at least 10 minutes in cleaning Solution A, rinse, sanitize with Solution B and reinstall. For units with integral ice-water bath beverage cooling only: 1. Remove dispenser lid and counter access panel opposite ice tower side. 2. Disengage service drain tube (on utility connection side of dispenser) from mounting bracket. 3. Pull bath service drain tube down through beverage line opening in counter and drain water bath into a bucket. 4. Use a bottle brush to clean coils with Solution A, rinse and sanitize with Solution B. 5. Reposition ice water bath drain tube in up position so water does not drain out. 6. Pour Solution A into ice water bath until it flows out of bath overflow drain. 7. Turn power ON to unit and dispense a small cup of ice to activate pump. 8. Allow pump to run for two minutes to clean pump and pump lines. 9. Turn power OFF. 10. Drain bath and replace drain tube in mounting bracket in up position to avoid siphoning water bath water. Putting unit back in service after quarterly cleaning 1. On units with integral beverage cooling, fill ice water bath with water until wa...

Эта инструкция также подходит к моделям:
Диспенсеры - U155BR400A/W (558.48 kb)
Диспенсеры - U155B (558.48 kb)
Диспенсеры - U155BR800A/W (558.48 kb)
Диспенсеры - U155BX (558.48 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории