Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Fluke, модель IMPULSE 6000D

Производитель: Fluke
Размер: 79.32 kb
Название файла: 7000dp__umeng0103.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


& Date: 1, 2/2008 CD PN: 3028681 © 2008-2009 Fluke Corporation. All rights reserved. Printed in the U.S.A. Impulse 6000D/7000DP Users Manual Supplement Change #1, 46470, 46697, 47714, 48007, 49680 Replace pages 31 through 35, with the following: Defibrillator Analyzer Specifications Energy Output Measurement Compatible Defibrillator Waveshapes ................ Lown, Edmark, Trapezoidal, DC Bi-phasic, and AC Pulsed Bi-phasic Note AC Pulsed Biphasic waveform has not been approved in the United States. Autoranged Measurement.................................... 0.1 to 600 J Accuracy 0.1 to 360 J ..................................................... ±(1 % of reading + 0.1 J) 360 to 600 J .................................................... ±(1 % of reading + 0.1 J), typical Note For Pulsed Bi-Phasic defibrillator, specified accuracy is ±(1.5 % of reading + 0.3 J) on both ranges. Load resistance Resistance .......................................................... 50 . Accuracy ......................................................... ±1 %, non-inductive (<2 .H) Pulse trigger level ................................................. 20 V Pulse width Range ................................................................. 1.0 to 50.0 ms 4/08 1 Manual Supplement Impulse 6000D/7000DP Users Accuracy............................................................. ±0.1 ms Voltage Range ................................................................. 20 to 5000 V Accuracy............................................................. ±(1 % of reading + 2 V) Current Range ................................................................. 0.4 to 100.0 A Accuracy............................................................. ±(1 % of reading + 0.1 A) Tilt (biphasic and pulsed biphasic) Range ................................................................. 1 % to 99 % Accuracy............................................................. ±1 digit Interphase delay (biphasic and pulsed biphasic) Range ................................................................. 0.1 ms to 9.9 ms Accuracy............................................................. ±0.1 ms Frequency (pulsed biphasic only) Range ................................................................. 2000 Hz to 8000 Hz Accuracy............................................................. ±1 % of reading Duty cycle (pulse biphasic only) Range ................................................................. 1 % to 99 % Accuracy............................................................. ±1 digit Sample rate ........................................................... 250 kHz (4 .s sample) Maximum Average Power .................................... 12 W, equivalent to 10 defib pulses of 360 J every 5 minutes 2 8/08 Impulse 6000D/7000DP Users Manual Supplement Scope Output Autorange ........................................................... 2000:1, 400:1 and 80:1: dependant on the range Waveform Playback Output ............................................................. BNC Output impedance........................................... 50 . Amplitude Accuracy ........................................ ±5 % Charge Time Measurement Range ................................................................. 0.1 to 100.0 s Accuracy .............................................................±0.05 s, typical Synchronization Test (Elective Cardioversion) Delay Time Measurement Timing window ................................................ ECG R-wave peak to the defib pulse peak Range ............................................................. -120 to +380 ms; measures timing from 120 ms prior to the R-wave peak to up to 380 ms following the R-wave peak. Resolution.......................................................1 ms Accuracy ......................................................... ±1 ms ECG waves Normal Sinus Rhythm (NSR)..........................10 to 180 (by 1) BPM Atrial fibrillation................................................ Coarse and fine Monomorphic Ventricular Tachycardia ........... 120 to 240 (by 5) BPM Asystole .......................................................... Flat line Automated Defibrillator Test ECG Waves Normal Sinus ...................................................... 10 to 300 (by 1) BPM 4/08 3 Manual Supplement Impulse 6000D/7000DP Users Ventricular Fibrillation ......................................... Coarse and fine Monomorphic Ventricular Tachycardia ............... 120 to 300 (by 5) BPM Polymorphic Ventricular Tachycardia ................. 5 types Asystole .............................................................. Flat line ECG Waves ECG General Lead configuration .............................................. 12-lead simulation. RA, LL, LA, RL, V1-6 with independent outputs Lead to lead impedance ..................................... 1000 . (nominal) Rate accuracy..................................................... ±1 % of nominal ECG ...

Эта инструкция также подходит к моделям:
CD-проигрыватели - IMPULSE 7000DP (79.32 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории