Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Honda Power Equipment, модель GXV390

Производитель: Honda Power Equipment
Размер: 525.84 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


4. Connect the battery negative (-) cable to the battery negative (-) terminal as shown. BATTERY NEGATIVE (-) BATTERY NEGATIVE (-) CABLE TERMINAL BATTERY BATTERY POSITIVE (+) TERMINAL STARTER SOLENOID BATTERY POSITIVE (+) CABLE 2 BEFORE OPERATION CHECKS BEFORE OPERATION CHECKS For your safety, and to maximize the service life of your equipment, it is very important to take a few moments before you operate the engine to check its condition. Be sure to take care of any problem you find, or have your servicing dealer correct it, before you operate the engine. . WARNING Improperly maintaining this engine, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always perform a preoperation inspection before each operation, and correct any problem. Before beginning your preoperation checks, be sure the engine is level and the throttle lever is in the STOP position. Always check the following items before you start the engine: 1. Fuel level (see page 5). 2. Oil level (see page 5). 3. Air cleaner (see page 6). 4. LPG models: cooling air filter (see page 6). 5. General inspection: Check for fluid leaks and loose or damaged parts. 6. Check the equipment powered by this engine. Review the instructions provided with the equipment powered by this engine for any precautions and procedures that should be followed before engine startup. LPG EQUIPMENT Carefully follow the installation and operating instructions of the LPG equipment manufacturer. OPERATION SAFE OPERATING PRECAUTIONS Before operating the engine for the first time, please review the SAFETY INFORMATION section on page 1 and the BEFORE OPERATION CHECKS section above. .WARNING Carbon monoxide gas is toxic. Breathing it can cause unconsciousness and even kill you. Avoid any areas or actions that expose you to carbon monoxide. Review the instructions provided with the equipment powered by this engine for any safety precautions that should be observed with engine startup, shutdown, or operation. ON SLOW FAST CHOKE STARTING THE ENGINE FUEL VALVE LEVER 1. Turn the fuel valve to the ON position. LPG Models: Turn the fuel valve on at the source. 2. STARTING A COLD ENGINE: Move the throttle control to the CHOKE position. STARTING A WARM ENGINE: Do not use the CHOKE position when the engine is warm. Move the throttle control slightly past the SLOW position. LPG Models: Always use the CHOKE position when starting the engine. 3. Recoil Start Models Pull the starter grip lightly until resistance is felt, then pull briskly. NOTICE Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter. 4. Electric Start Models Turn the engine switch to the START position, and hold it there until the engine starts. When the engine starts, allow the engine switch to return to the ON position. NOTICE Do not use the starter for more than 5 seconds or starter motor damage may occur. If the engine fails to start, release the switch and wait 10 seconds before operating the starter again. 5. If the choke was used to start the engine, move the throttle to the FAST (or HIGH) position as soon as the engine warms up enough to run smoothly without use of the choke. SETTING ENGINE SPEED SLOW FAST Position the throttle control for the desired engine speed. For best engine performance, it is recommended the engine be operated with the throttle in the FAST (or high) position. OFF OIL ALERT® BUZZER (oil alert type only) The OIL ALERT buzzer will warn you before the engine oil level falls below the safe operating limit. If the buzzer sounds, stop the engine immediately and add oil (see page 5). NOTICE The buzzer indicates insufficient oil. Running the engine with insufficient oil can cause serious engine damage. 3 STOPPING THE ENGINE STOPPING THE ENGINE . Recoil Start Models Move the throttle control to the SLOW position. 2. Move the throttle control to the stop position. SLOW Electric Start Models OFF Move the throttle control to the slow position, then turn the engine switch to the OFF or STOP position. 3. Turn the fuel valve lever to the FUEL VALVE LEVER OFF position if you do not intend to restart the engine soon. LPG Models: Turn the fuel valve OFF at the source. OFF SERVICING YOUR ENGINE THE IMPORTANCE OF MAINTENANCE Good maintenance is essential for safe, economical and trouble-free operation. It will also help reduce pollution. . WARNING Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously hurt or killed. Always follow the inspection and maintenance recommendations and schedules in this owner’s manual. To help you properly care for your engine, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools. Other service tasks that are more difficult, or require special tools, are best handled by professionals and are normally performe...

Эта инструкция также подходит к моделям:
Бензо и электропилы - GVX340 (525.84 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории