This manual supplies information for the installation, operation, and servicing of the appliance. READ AND REVIEW THIS MANUAL COMPLETELY before proceeding with an installation. Its use will reduce service calls and chance of injury and will lengthen product life. If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Call (800) 831-7133 for additional free copies of these instructions. FOR YOUR SAFETY Do
3. Test the operation of the pressure relief valve by lifting the valve lever. 4. Test for proper operation of the pressure switch. (See “SWITCH SETTINGS” for testing instructions). 5. On enclosed installations with high-temperature Special Gas Vent systems, repeat the “Final Installation Check,” page 15. Check for evidence of joint leakage. Make sure that joints have not slipped partially or completely apart. Check pipe and fittings for cracks or breaks. The combustion air blower is permanently
To override the time delay, push the Max. Temp. Set Point button again. D. Press the ^ ^^ TEMP or Ў ЎЎ TEMP button on the control panel and set maximum spa temperature to 104°F (40°C) or less. E. Wait up to 30 seconds; the SPA ON light will go off and the unit will shut down. To override the time delay, push the Max. Temp. Set Point button again. 4. Reinstall the access door panels. Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service
Use a Listed roof flashing, roof jack, or roof thimble for all roof penetrations. Do not fill the space around the vent (that is, the clear air space in the thimble or firestop) with insulation. The roof opening must be located so that the vent is vertical. 6. Vent Termination – Vertical (See Figures 12A and 12B, page 13, for height of vent termination above the roof. See Table 7, Page 15, for Listed terminations.) Use a Listed vent terminal specified by local and national codes and your manufac
to 5 P.M.) Phone: (800) 831-7133 Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 (Ext. 6312) Fax: (800) 284-4151 Web sites: visit and © 2005 Pentair Water Pool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Trademarks and disclaimers: IntelliFlo, IntelliTouch and the Pentair Water Pool and Spa logo are trademarks of Pentair Wate
You can schedule start and stop times for each feature. All Features are operated using Flow control. The Feature mode and Filter mode are run simultaneously. The three types of features are; Features 1 & 2, Features 3 -9 and M.O. Flo: Features 1 and 2 Feature 1 and Feature 2 run for a pre-defined duration with a specifically set flow. If Feature 1 or Feature 2 buttons are pressed, all other Features are temporarily deactivated. Feature 1 or Feature 2 cannot be used in Backwash Mode. Features 1
FAILURE TO READ AND FOLLOW INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY AND/OR MAJOR PROPERTY DAMAGE. TABLE OF CONTENTS A. HOW YOUR PUMP WORKS.............2 B. SELECTION OF PUMP AND PIPING .. 2-4 C. INSTALLATION.........................4-8 D. PUMP OPERATION & MAINTENANCE.......................... 8 E. DISASSEMBLY/ASSEMBLY PROCEDURE FOR SEAL REPLACEMENT......................9-11 F. WINTERIZING PROCEDURE............11 G. TROUBLESHOOTING GUIDE............11 H. REPLACEMENT PARTS...
NPT PRV. NOTE: (A.S.M.E. version varies slightly. It is of bronze construction, and is supplied with the A.S.M.E. Section IV, pressure relief valve pre-installed at factory.) Test the relief valve at least once a year by lifting up lever. Figure 29. ENERGY SAVING TIPS 1. If possible, keep pool or spa covered when not in use. This will not only cut heating costs, but also keep dirt and debris from settling in the pool and conserve chemicals. 2. Reduce the pool thermostat setting to 78° F.
4. Pull the long gear shaft straight up (Figure 23a) by the blocks on the ends of the shaft. Hold the seals in the oscillator and the blocks on the shaft. The cam may interfere with the shaft mounting post; if so, turn it slightly on the shaft until it clears the post. The shaft assembly can now be disassembled (Figure 23b). 5. Slide the long gear shaft out of the oscillator (with gears, complete); make sure that you don’t lose the seals out of the oscillator which may fall out at this point (Fi
Do NOT sanitize the pool by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high concentration of chlorine to enter the heater, which could cause corrosion damage to the heat exchanger. WATER PRESSURE SWITCH WARNING Hazardous pressure. Do not bypass the Water Pressure Switch or render it inoperable. Switch Settings The water pressure switch turns off the burner if the water flow is interrupted. If the water flow is restricted, the water pressure sw