Additionally, if the bottom edge of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on the bottom edge. 1. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. 2. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. IMPORTANT SAFETY INFORMATION TIONTION WARNING - Not following these instructions may cause severe injury or death to persons. Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm UL325 standard requires an audible alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor). The audible alarm will continue to sound for 5 minutes or until a stop command gets actuated. The Stop command can be actuated in two different forms 1. Using the Built in Stop switch on the Control Box or 2. Using an External Stop button within the sight of the gate, away from moving parts of the gate and out of reach of children. 3. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 4. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start. TECHNICAL SUPPORT 1 800 908 08848Warning Placard Installation Manual Stop Button 5' Minimum STOP Open CommandsGuard StationMaster/Slave StopOpenGNDCloseStopOpenGndFireGndStrikeGnd COM N.O. STOP All Warning Signs and Placards must be installed where visible in the area of the gate. A minimum of two placards shall be installed. A placard is to be installed in the area of each side of the gate and be visible. IMPORTANT INSTALLATION INFORMATION TIONTION CAUTION -FOR USE WITH GATES OF A MAXIMUM OF 14 FT IN LENGTH AND 600 LBS. IN WEIGHT. WARNING -TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS: This is NOT a pedestrian gate operator Do NOT Install the gate operator to lift gates 14’ maximum gate length 600 pounds maximum gate weight Locate Control Buttons: 1. Within sight of the gate, 2. At a minimum height of 5 feet so small children are not able to reach it, and 3. Away from all moving parts of the gate. 600 lb. MAX. 14'-0" CLOSE STOP OPEN Control Control ButtonsButtons Control Buttons Specifications Maximum Gate Length: 14 feet Maximum Gate Weight: 600 lbs. Maximum Aperture Angle: 130 deg. Power Requirements: 120 VAC Single Phase at 2 Amps Or 220 VAC Single Phase at 1 Amp Maximum Operating Temperature: -20°C (-4°F) to 70°C (158°F) TECHNICAL SUPPORT 1 800 908 0884 9 PLAN OF INSTALLATION - OPEN INSIDE TION - OPEN INSIDETION - OPEN INSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. Inside Outside Inside Outside Gate in Closed Position Gate in Closed Position 90° Opening A: 15-3/4" Max. C: 23-1/2" C: 19-1/2" F: 15-1/2" Min. Gate in Open Position F: 15-1/2" Min. 7-1/4" Max. 120° Opening Gate in Open Position G: 4.33" Ref. H: 2.55" Ref. G: 4.33" Ref. H: 2.55" Ref. Figure B – Up to 120° Opening Figure A – 90° Opening Open Inside Plans of Installation Note: Varying from the dimensions shown may severely affect the speed and performance of the gate operator. TECHNICAL SUPPORT 1 800 908 088410 PLAN OF INSTALLATION – OPEN OUTSIDE TION – OPEN OUTSIDETION – OPEN OUTSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. Inside Outside Gate in Closed Position C: 19-1/2" 90° A: 11-3/4" Max. G: 4.33" Ref. H: 2.55" Ref. Gate in Open Position Figure C Open Outside Plan of Installation TECHNICAL SUPPORT 1 800 908 0884 11Note: Varying from the dimensions shown may severely affect the speed and performance of the gate operator. STEP 1 Check the integrity of the gate structure and sufficiently sturdy such as pivot points are properly lubricated and surfaces are free of rust. a) Remove the Motor/Gear Assembly from its package. NOTE - The cover is not secured. b) Disassemble the geared motor from the mounting chassis. STEP 2 Position the pivot bracket in accordan...

Эта инструкция также подходит к моделям:
Автоматические ворота - Vehicular Gate Opener UL 325 (1.17 mb)
Автоматические ворота - Vehicular Gate Opener X-9 (1.17 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории