Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Genie, модель 1022

Производитель: Genie
Размер: 3.42 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


4-5b Pre-Wired source and sensor wiring methods. 6 5 4 3 2 1 or 6 5 4 3 2 1 Source Sensor Red Green Power Head Dashed Line = striped wire Solid Line = white wire Wall Wall Ceiling 1/2" 2" Cover clips FIG. 4-9 Install rear cover. Insulated Staple Wire Nut CONNECTING TO POWER 5 Plug the operator into a properly grounded electrical outlet. (Fig. 5-1) • To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door operator must be properly grounded in order to prevent personal injury and damage to the components. • DO NOT remove motor cover. All work performed on motor must be done by a trained professional service technician. WARNING • Check local building codes to make sure that you are not required to have your garage door operator permanently wired, with circuit breaker protection. If building codes require door operator to be permanently wired have a qualified licensed electrician connect power with permanent wiring. CAUTION WITH GROUNDED PLUG: WITH PERMANENT WIRING: Instructions for Electrician. • Remove power from circuit. • Remove rear cover and motor cover. – Remove four motor cover screws (Fig. 5-2). • Remove existing power cord and strain relief from the 7/8" dia. hole and discard. (Fig. 5-3) • Connect permanent wiring to power head using 7/8" diameter hole. CONNECTING TO POWER 5 Plug the operator into a properly grounded electrical outlet. (Fig. 5-1) • To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified licensed electrician to install one. DO NOT alter the plug in any way. The door operator must be properly grounded in order to prevent personal injury and damage to the components. • DO NOT remove motor cover. All work performed on motor must be done by a trained professional service technician. WARNING • Check local building codes to make sure that you are not required to have your garage door operator permanently wired, with circuit breaker protection. If building codes require door operator to be permanently wired have a qualified licensed electrician connect power with permanent wiring. CAUTION WITH GROUNDED PLUG: WITH PERMANENT WIRING: Instructions for Electrician. • Remove power from circuit. • Remove rear cover and motor cover. – Remove four motor cover screws (Fig. 5-2). • Remove existing power cord and strain relief from the 7/8" dia. hole and discard. (Fig. 5-3) • Connect permanent wiring to power head using 7/8" diameter hole. – White to white/black to black/ground to green. – Use only UL recognized wire nuts. • Wires inside the power head must be at least 6" in length. • Replace motor cover and rear cover and re-energize the circuit. NOTE: The Genie Company is not responsible forcharges resulting from work preformed by anindependent electrician. WITH POWER SUPPLIED: Check Safety Beam alignment (Fig. 5-4). • Insure that no part of door or its hardware is in path between lenses of source and sensor. • Insure that tops of lenses are between 5" - 6" above the floor (Fig. 5-4). The brackets are flexible, and can be adjusted slightly if needed. • Adjust the Red LED transmitter by aiming the unit directly at the Green LED receiver. Use the adjustment screw located on the top of the transmitter housing to make adjustments. • The Red LED transmitter will blink if there is a misalignment. When the LED units are aligned the Red LED will remain ON continuously. • After the alignment is finished tighten the adjustment screws on both sensors. FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM 5" from floor FIG. 5-4 Check Safety Beam Alignment. FIG. 5-1 Connect to power. INFRARED PROTECTION FUNCTION 1. When the garage door is opening, its movement will not be influenced if the safety beam is obstructed. 2. If the safety beam is obstructed before the garage door closes, the door will not close. 3. When the garage door is closing, if safety beam is cut off by people or obstacle, the garage door will reverse automatically to its fully opened position. (Meanwhile, the opener light will keep blinking until door moves to its fully opened position.) 4. If the Safety Beam System fails, loses power, or is installed improperly, you will have to press and hold the wall control "close" button until the door reaches its fully closed position. The LED indicator light on the power head will be green and blink twice (Pattern: 00 pause 00 pause) to inform you to eliminate problem first. Otherwise, the door will reverse automatically to its fully opened position if you release the "close" button on the wall control during the closing movement. FIG. 5-2 Remove motor cover. Motor Cover Screws FIG. 5-3 Power cord strai...

Эта инструкция также подходит к моделям:
Автоматические ворота - 1024 (3.42 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории