Фрагмент инструкции


A small Plastic Pin is provided to secure the other end of the Receiver to the panel. For proper operation, the Antenna Wire should be POINTED STRAIGHT DOWN toward the floor. After installing the Radio Controls, check their operation by moving approximately 35 FT away from the garage door and pressing the Transmitter Button. Operation at this distance should be reliable. If the Transmitter doesn't activate door operation, check that all Coding Switches are set identically. If the operational distance is inadequate, try moving the position of the Transmitter in the car. If the distance is still inadequate, try bending the Antenna Wire to a different angle. If the distance is still inadequate, replace the Battery with a standard 9- Volt “transistor radio” Battery (NEDA 1604). The Battery is located in the front compartment next to the Coding Switches. The Transmitter may be hand held if desired by removing the Visor Clip from the rear of the Case as illustrated. Place your finger in the loop at the top of the visor, and your thumb on the top edge of the Transmitter. Push down with your thumb and pull up with your finger. Clip will release and pull out easily. WARNING TO PREVENT THE RISK OF PERSONAL INJURY, DAMAGE TO DOOR OR PROPERTY, ONLY OPERATE DOOR CONTROLS WHEN DOOR IS IN CLEAR VIEW. KEEP REMOTE CONTROL AWAY FROM CHILDREN IN SECURE AREA. TRANSMITTER: To gain access to the Transmitter Coding Switches, remove the Battery Cover from the front of the Transmitter by sliding it toward the bottom of the Transmitter as illustrated. RECEIVER: The Receiver Coding Switches can be accessed by removing the small door from the back of the Receiver using a small screwdriver or knife. CODING BLOCK: Transmitter and Receiver Coding Switches are contained in identical Coding Blocks, consisting of nine small switches, labeled 1 - 9, each of which can be set in any of three positions, labeled +, 0, - 104384 104385 104386 POINT ANTENNA STRAIGHT DOWN PLASTIC PIN 104387 104388 D: AUXILIARY EQUIPMENT 16 D: AUXILIARY EQUIPMENT INSTALLATION OF DELUXE WALL STATION The Allstar Plus Deluxe Wall Station is an optional accessory designed to work with any Allstar 3000 Series Operator. Connection to any other operator may damage the operator and/or Wall Station. Only connect one operator to each Wall Station. Do not connect more than one Wall Station to an Operator. STEP 1: After determining a suitable location, usually near the access door And at least 5 feet above the floor to prevent use by children, use the Wall Station as a guide to mark the mounting holes. Drill holes for drywall anchors or screws. NOTE: Do not mount directly to masonry walls. Use backer board. STEP 2: A length of 4-conductor, #22 gauge wire is required to connect the Wall Station to the garage door operator. Strip approximately 6” of the wire jacket from one end and 1/2” of insulation from each wire. Carefully connect one wire to each of the four terminals indicated, noting which color is connected to which terminal. Tighten screws, being careful that no wires are allowed to touch any other terminal or any other conductive part of the circuit board. Do not overtighten the terminal screws. STEP 3: Push the wire jacket into one of the four notches provided at the ends of the housing, allowing a maximum of 1/8” inch of the jacket inside the case (too much will make mounting difficult). Carefully tuck the loose wires into the case and mount the unit using the screws provided. STEP 4: Run the wire from the Wall Station to the operator, supporting it at 18” intervals with suitable staples. Leave a sufficient length to make the necessary connections to the operator terminal strip. WARNING: SOME LOCAL BUILDING CODES DO NOT ALLOW SURFACE WIRING. BE SAFE AND CHECK WITH YOUR LOCAL BUILDING INSPECTOR FIRST. STEP 5: Disconnect the power from the operator. Strip approximately 8” of jacket from the end of the wire and 1/2” insulation from each wire. Connect to terminals 0, 1, 4 and 5 as shown in the illustration above. Support the wire near the operator with wire ties. STEP 6: Reconnect power to the operator and test the Deluxe Wall Station functions as described in the Operation and Adjustment Instructions. Please note the following Operating Parameters which apply to Openers with Auxiliary Entrapment Protection System connected. (All-Clear Photosystem, Installation Instructions on Page 13.) IF THE DOOR IS... ...FULLY OPEN, then pushing the standard wall Push Button will cause the door to begin MOVING DOWNWARD. ...FULLY CLOSED, then pushing the wall Push Button will cause the door to begin MOVING UPWARD. ...STOPPED, PARTIALLY OPEN, then pushing the wall Push Button will cause the door to begin MOVING UPWARD. ...MOVING UPWARD, then pushing the wall Push Button will cause the door to STOP. ...MOVING DOWNWARD, then pushing the wall Push Button will cause the door to STOP, PAUSE FOR APPROXIMATELY ONE SECOND, AND THEN BEGIN MOVING UPWARD. E: OPERATING PARAMETERS 4-CONDUCTOR 22 GAUGE ...

Эта инструкция также подходит к моделям:
Автоматические ворота - J3500 (1.33 mb)
Автоматические ворота - 3000 (1.33 mb)
Автоматические ворота - 3500-P (1.33 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории