Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Brinkmann, модель 8300

Производитель: Brinkmann
Размер: 6.72 mb
Название файла: 810-8300-F.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


• Always use a protective cylinder cap when grill is not connected to cylinder. • If you exchange a cylinder with a qualified exchange program, be sure the cylinder has a Type 1 valve and an over-filling prevention device (OPD). INSTALLING THE LP GAS CYLINDER ONTO THE GRILL: 1. Check that the cylinder valve is closed by turning the knob clockwise. 2. Place the cylinder into the tank holder in the bottom of cart base. 3. Orient the cylinder such that the valve opening faces the side burner, and so that the hose is not kinked or damaged. 4. Attach or detach regulator to the LP gas cylinder only when cylinder is at rest in tank holder. HOSE AND REGULATOR: Your grill is equipped with a Type 1 connection device with the following features: 1. The system will not allow gas flow from the cylinder until a positive connection to the valve has been made. Note: The cylinder valve must be turned off before any connection is made or removed. 2. A thermal device that will shut off the gas flow if the device is subject to temperatures above 240°F to 300°F (115°C to 150°C). If this should happen, remove the entire regulator assembly and dispose of properly. A replacement regulator assembly can be purchased by contacting customer service at 800-527-0717. The cause of the excessive heat should be determined and corrected before using your grill again. 3. A regulator flow limiting device, when activated, restricts the flow of gas to 10 cubic feet per hour. If the flow limiting device is activated, perform Regulator Resetting Procedure. REGULATOR RESETTING PROCEDURE 1. Turn burner control knobs to "OFF", turn off the cylinder valve and disconnect regulator from LP gas tank. Wait approximately two minutes. 2. Reattach regulator and slowly turn cylinder valve back on. The flow limiting device will now be reset. WARNING • Never use your grill without leak testing all gas connections and hoses. See the section on "Leak Testing" in this manual for proper procedures. WARNING The pressure regulator and hose assembly supplied with your gas grill must be used. • DO NOT attempt to connect it to any other fuel supply source such as a natural gas line. • DO NOT use any other pressure regulator/hose assembly other than the one supplied with your grill. Replacement pressure regulator/hose assembly must be part No 155-8300-F, which can be obtained by contacting customer service at 800-527-0717. • DO NOT attempt to adjust or repair the regulator. The regulator is designed to operate at a maximum output pressure of 11 inches of water column (2.74 kPa). During assembly and/or replacement of the gas cylinder, keep the gas supply hose free of kinks and/or damage. Visually inspect the hose assembly prior to each use for evidence of damage, excess wear, or deterioration. If found, replace the assembly before using your grill. Only the manufacturer's supplied replacement should be used. WARNING CONNECTING HOSE AND REGULATOR TO AN LP GAS CYLINDER • Ensure the tank valve is CLOSED prior to connecting the LP gas cylinder to your grill. Turn the valve knob clockwise to properly close the valve. Read and follow all instructions and warnings on the supply hose safety tags. Read and follow all warnings in this manual concerning the safe use of LP gas cylinders and the hose and regulator before connecting cylinder to grill. Read and follow all warnings on the LP cylinder. CONNECTING HOSE AND REGULATOR 1. Check that the cylinder valve is closed by turning the knob clockwise. 2. Check that the grill’s burner control knobs are in the "OFF" positions. 3. Remove the protective plastic cap from the cylinder valve and the connection device. 4. Hold regulator and insert the nipple of connection device into the LP cylinder valve outlet. Ensure that the device is centered properly. 5. Turn the large coupling nut clockwise by hand and tighten to a full stop. Take care not to cross thread the coupling nut onto the cylinder valve. Do not over-tighten the knob onto the valve. Do not use tools to tighten connection. Note: If you are unable to make the connection, repeat Steps 4 and 5. 6. Check that the hose does not contain kinks, does not contact sharp edges, and does not contact surfaces that may become hot during use. 7. Leak check all fittings before lighting your grill. See section on "Leak Testing" in this manual. To prevent fire or explosion hazard: • DO NOT smoke or permit ignition sources in the area while conducting a leak test. • Perform test OUTDOORS only in a well ventilated area. • Never perform a leak test with a match or open flame. • Never perform a leak test while the grill is in use or while grill is still hot. LEAK TESTING: DANGER LEAK TESTING: DANGER WHEN TO PERFORM A LEAK TEST: • After assembling your grill and before lighting for the first time, even if purchased fullyassembled. • Every time the LP gas cylinder is refilled or if any of the gas components are replaced. • Any time your grill has been moved. • At least once per year or if your grill ha...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории