Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Weil-McLain, модель 1050FFD-W

Производитель: Weil-McLain
Размер: 79.05 kb
Название файла: 06f05d77-016b-4728-8c35-50de303c1a25.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Standard Motor Electrical Characteristics Optional Motor Electrical Characteristics Approximate Shipping Weight 702CRD-W 1/2 120/60/1 240/60/1* 75 801CRD-W 3/4 240/60/1 208-240/460/60/3 90 1050FFD-W 1 240/60/1 208-240/460/60/3 135 1150FFD-W 1 1/2 240/60/1 208-240/460/60/3 135 * Optional motor contactor supplied. Part No. 550-142-030/0508 Weil-McLain 88 Water and Steam Boilers — Series 2 — For Light Oil-Fired Burners Burner specifications and settings Table 1 Burner data Boiler Model Number Burner Input (Forced Draft) No. 2 Oil Gph Low Fire Firing Rate No. 2 Oil Gph Positive Pressure In Firebox Inches W.C. Standard Burner Model Designation Standard Combustion Control Starting Head Setting Approximate Air Settings Low Fire 488R 6.90 3.90 0.55 702CRD-W 60200 7/32 5/16 488 7.00 4.00 0.55 702CRD-W 60200 7/32 5/16 588 9.40 5.42 0.61 702CRD-W 60200 13/16 1/2 688 11.80 6.60 0.55 801CRD-W 60200 3/16 1/4 788 14.20 7.00 0.60 801CRD-W 60200 5/8 1/2 888 16.60 8.00 0.85 801CRD-W 60200 1 3/8 988R 17.20 8.90 0.65 1050FFD-W 60200 3/8 3/8 988 18.80 8.92 0.70 1050FFD-W 60200 1/2 1/4 1088R 20.00 9.60 0.70 1050FFD-W 60200 1/2 3/4 1088 21.50 10.10 0.70 1050FFD-W RM7840L-1018 1/2 3/4 1188 23.50 12.00 0.75 1150FFD-W RM7840L-1018 1/4 11/16 1288 26.00 12.54 0.75 1150FFD-W RM7840L-1018 7/16 7/8 1388 28.50 13.44 0.80 1150FFD-W RM7840L-1018 11/16 7/8 1488 31.00 15.10 0.75 1150FFD-W RM7840L-1018 1 1 Notes for Table 1 and Table 2 Burner capacities listed for elevations up to 2,000 feet. For 1. higher elevations, consult local Weil-McLain distributor/ agent or sales office. b. RM7840L-1018 combustion safety control (for over 20 GPH applications) uses an ultraviolet flame detector to monitor oil flame and provides purge timings. Light oil ratings based on No. 2 fuel oil with heating value of 2. 140,000 Btu per gallon. Boiler-burner unit to be adjusted to achieve +0.10 inches 3. W.C. pressure at the flue collar, resulting in positive pressure in firebox as listed. Combustion Controls: 4. 60200 combustion safety control uses a cadmium sulfide a. cell flame detector to monitor oil flame; provides interrupted duty, recycle type operation, latch-up feature, 30-second oil valve delay on, 30-second post purge, alarm contacts and safety monitor circuit. 5. 6. 7. All motors furnished with integral overload protection with manual reset. Mechanical pressure atomizing oil control system with on/ off operation, low fire start, high fire run and two-position air control is standard. Low-High-Low fire operation can be obtained by addition of SPST temperature or pressure controller. 120/60/1 control circuit is used for all burners. 2 Part No. 550-142-030/0508 Burner Specification & Data sheet — Carlin Oil Burners Burner specifications and settings (continued) Table 2 Fuel unit and oil components Boiler Model Number Oil Nozzles Operating Oil Pressure Psig Fuel Unit Burner-Motor Driven, 3450 Rpm Qty Size Gph Brand Type Angle Low Fire High Fire Type (Suntec) Gearset Capacity, Gph 488R 1 4.0 Hago P...

Эта инструкция также подходит к моделям:
Грили - 702CRD-W (79.05 kb)
Грили - 801CRD (79.05 kb)
Грили - 1150FFD (79.05 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории