Войти:
Оценок - 5, средний балл: 4.8 ( )

Инструкция по эксплуатации Weil-McLain, модель 702CRD-W

Производитель: Weil-McLain
Размер: 79.05 kb
Название файла: 06f05d77-016b-4728-8c35-50de303c1a25.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


For 1. higher elevations, consult local Weil-McLain distributor/ agent or sales office. b. RM7840L-1018 combustion safety control (for over 20 GPH applications) uses an ultraviolet flame detector to monitor oil flame and provides purge timings. Light oil ratings based on No. 2 fuel oil with heating value of 2. 140,000 Btu per gallon. Boiler-burner unit to be adjusted to achieve +0.10 inches 3. W.C. pressure at the flue collar, resulting in positive pressure in firebox as listed. Combustion Controls: 4. 60200 combustion safety control uses a cadmium sulfide a. cell flame detector to monitor oil flame; provides interrupted duty, recycle type operation, latch-up feature, 30-second oil valve delay on, 30-second post purge, alarm contacts and safety monitor circuit. 5. 6. 7. All motors furnished with integral overload protection with manual reset. Mechanical pressure atomizing oil control system with on/ off operation, low fire start, high fire run and two-position air control is standard. Low-High-Low fire operation can be obtained by addition of SPST temperature or pressure controller. 120/60/1 control circuit is used for all burners. 2 Part No. 550-142-030/0508 Burner Specification & Data sheet — Carlin Oil Burners Burner specifications and settings (continued) Table 2 Fuel unit and oil components Boiler Model Number Oil Nozzles Operating Oil Pressure Psig Fuel Unit Burner-Motor Driven, 3450 Rpm Qty Size Gph Brand Type Angle Low Fire High Fire Type (Suntec) Gearset Capacity, Gph 488R 1 4.0 Hago P 70° 100 300 B2TA-8851 33 488 1 4.0 Hago P 70° 100 300 B2TA-8851 33 588 1 5.5 Hago P 60° 100 300 B2TA-8851 33 688 2 1-5.5 1-4.5 Hago H 45° 150 150 B2TA-8260 39 788 2 1-6.0 1-5.5 Hago H 45° 150 150 B2TA-8260 39 888 2 1-6.5 1-7.0 Hago H 45° 150 150 B2TA-8260 39 988R 3 1-9.0 2-4.0 Hago SS 45° 110 100 J4PB-B1000G 46 988 3 1-9.0 1-6.0 1-5.5 Hago SS 45° 110 100 J4PB-B1000G 46 1088R 3 1-10.0 2-5.0 Hago SS 45° 110 100 J4PB-B1000G 46 1088 3 1-10.0 1-6.0 1-5.5 Hago SS 45° 110 100 J4PB-B1000G 46 1188 3 1-12.0 1-6.0 1-5.5 Hago SS 45° 110 100 J4PB-B1000G 46 1288 3 1-12.0 2-7.0 Hago SS 45° 110 100 J4PB-B1000G 46 1388 3 1-13.0 1-7.5 1-8.0 Hago SS 45° 110 100 J4PB-B1000G 46 1488 3 1-13.0 1-8.0 1-7.5 Hago SS 45° 110 100 J4PB-B1000G 46 Part No. 550-142-030/0508 Weil-McLain 88 Water and Steam Boilers — Series 2 — For Light Oil-Fired Burners Burner dimensions Figure 3 Carlin models 702CRD-W and 801CRD-W Burner Dimensions, In Inches Model Number A B C D E F G H J K L W 702CRD-W 7.50 9.50 10.00 5.88 13.00 9.00 4.13 4.00 3.00 3.00 20.75 19.50 801CRD-W 8.00 12.00 11.00 5.88 14.50 10.50 5.25 4.00 3.00 3.00 20.50 23.00 Figure 4 Carlin models 1050FFD-W and 1150FFD-W Burner Model Number Dimensions In Inches A B C D E F G H J K L N W 1050FFD-W 1.63 4.00 11.50 8.63 5.25 11.00 10.75 12.00 13.00 3.00 25.63 18.75 25.00 1150FFD-W 2.13 4.00 11.88 9.88 6.25 11.00 10.75 12.00 13.00 3.00 25.88 18.75 25.00 Part No. 550-142-030/0508 ...

Эта инструкция также подходит к моделям:
Грили - 1050FFD-W (79.05 kb)
Грили - 801CRD (79.05 kb)
Грили - 1150FFD (79.05 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории