Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Dacor, модель OGC36

Производитель: Dacor
Размер: 1002.16 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If the burners fail to light or are not functioning properly, shut off the main gas supply valve and call your local service agency for inspection. 13. Never block the vents located on the back of the grill or the opening at the rear of the canopy. Blocking any or all of these vents during cooking, will result in damage to the unit and may cause a fire or injury. Grill Features 13121110678691454132 Liquid Propane Tanks 1. Dacor LP model grills are set at the factory for LP tank installations. Use only the Dacor supplied regulator. DO NOT ATTEMPT FIELD CONVERSIONS. Approved field conversions from natural to LP or LP to natural will only be approved when completed by an authorized Dacor servicer. 2. Dacor grills are approved for a maximum LP tank capacity of 20 pounds (5 gallons). The tank must be constructed and marked in accordance with the specifications for LP-gas tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, tank, Spheres and Tubes of the Transportation of Dangerous Goods. To minimize the potential for fire or an explosion, the following precautions should be observed when using, filing, or storing an LP tank: • Never use a dented or rusty LP tank. If there is any question as to the soundness of the tank, have it checked by your LP supplier. • Never use a tank with a damaged or defective shut off valve. • Do not over fill the LP tank. Never fill the tank beyond eighty percent (80%) of its capacity. Overfilling will cause the pressure relief valve on the tank to vent excess gas vapor. This vapor is combustible and can ignite, causing a fire. • When transporting an LP tank, ensure it is in an upright position and away from any sources of high heat. • Do not store additional LP tanks inside the cart of the unit. Tanks must be stored outdoors in a well-ventilated area out of the direct sunlight and/or sources of high heat, and out of the reach of children. • LP tank supply systems must be arranged for vapor withdrawal. • LP tank used must include a collar to protect the tank valve. IMPORTANT: 1. For your safety, the gas supply must be turned off at the LP-gas supply tank when your grill is not in use. 2. The LP-gas supply cylinder must be disconnected when this barbecuing appliance is not in use. 3. If the appliance is to be stored indoors, the LP tank must be disconnected and removed from the appliance. 4. LP tanks not connected for use shall not be stored in the vicinity of this or any other appliance. 5. Detach and leave the tank outdoors if storing the unit indoors. These grills are for outdoor use only. 6. Check for leaks after every tank change. Built in Model EOG36 Features EOG36 Features: 1. Rotisserie control knob 2. Grill and Smoker control knobs 3. Drip retrieval tray 4. Interior lights on/off switch 5. Stainless steel grills 6. Halogen cooking lights 7. Infrared rotisserie burner (13,000 BTU) 8. Canopy mounted temperature gauge 9. Keep warm rack 10. Rotisserie Rod and forks 11. Rotisserie Motor 12. Rotisserie Bracket 13. Removable smoker box 14. Heat control channels 1110786954132 Built in Model EOG52 Features EOG52 Features: 1. Rotisserie control knob 2. Grill and Smoker control knobs 3. Drip retrieval tray 4. Interior lights on/off switch 5. Stainless steel grills 6. Halogen cooking lights 7. Infrared rotisserie burner (13,000 BTU) 8. Canopy mounted temperature gauge 9. Side burner control knobs 10. Side burners (2 - 18,000 BTU) 11. Burner grate Keep warm rack (not shown) Rotisserie Rod and forks (not shown) Rotisserie Motor (not shown) Rotisserie Bracket (not shown) Removable smoker box (not shown) Heat control channels (not shown) Install Liquid Propane (LP) Tank Slideout LP TankStorage SelfMain Tank ValveTank GasRegulatorFlexible Gas LineLP Tank(5 Gal Max.) Gas Connection atRight Read CornerUnder Outdoor Grll Lift up workSurfaceFixedwheelsRoll out storageDrawers (2) Roll outLP tankshelfGas andElectricalLockingwheel Installing the LP Tank Lighting Liquid Propane Grills WARNING: Open canopy before attempting to light the appliance. Failure to open the canopy could allow gas to accumulate which could cause an explosion. NOTES: 1. Reference your installation instructions for proper LP gas line connections to the Dacor regulator and the “Main tank valve”. 2. Once the tank is properly installed: • Open the canopy to full open position. • Turn on the main tank valve. • Light one grill burner at a time by pressing in on the control knob and turning it counter clockwise until you hear the clicking ignition sound. Your burner should ignite within 4 to 10 seconds. • Repeat the last step with all control locations. Freestanding Cart Model OGC36 Features Lift up workSurfaceFixedwheelsRoll out storageDrawers (2) Roll outLP tankshelfGas andElectricalLockingwheel Lighting Natural Gas Grills WARNING: Open canopy before attempting to light the appliance. Failure to open the canopy could allow gas to accumulate which could cause an explosion. NOTES: 1. R...

Эта инструкция также подходит к моделям:
Грили - EOG52 (1002.16 kb)
Грили - OGC52 (1002.16 kb)
Грили - EOG36 (1002.16 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории