Производитель: Beckett
Размер: 1.2 mb
Название файла:
|
Фрагмент инструкции
Combination Rate Nozzle Setting Shutter Band Press. Press. Flange Inserti°n 214A AFG B2007 AFG50MLSS 1.20 1.00x60B 1 10 1 N/A 150 51311 4.50" 215A AFG B2007 AFG50MLSS 1.55 1.25x45B 2 10 3 N/A 150 51311 4.50" 216A CF375 BCF3907 CF56KY 1.90 1.35x45ES 1 7-1/2 0 N/A 200 51311 4.50" 217A CF500 BCF809 CF60KK 2.25 1.75x45B 2 4 0 N/A 150 51311 3.75" 218A CF500 BCF809 CF60KK 2.50 2.00x45B (D) 2 5 0 N/A 150 51311 3.75" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. DeDietrich GT300 Series Boiler Blue - Red - Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Low Fire Air or Shutter High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 304 CF500 BCF809 CF60KK 2.82 2.25x45P 1 4 1 N/A 150 51628 5.50" 305 CF800 BCF403 CF80KH 4.10 3.50x45P 1 6-1/2 0 N/A 140 51628 5.00" 306 CF800 BCF403 CF80KH 5.60 4.50x45P 4 10 2-1/2 N/A 150 51628 5.00" 307 CF1400 BCF205 CF66KD 7.10 4.25x45P 3 28 40 150 300 51312 5.00" 308 CF1400 BCF205 CF66KD 8.50 5.00x45P 6 35 45 150 300 51312 5.00" 309 CF2300A BCF304 CF102KG 10.00 6.00x45P 0 28 30 125 275 51313 5.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. Dunkirk DPFO Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue -Low Fire Air or Shutter Red -High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 6 CF375 BCF3907 CF56KZ 2.10 1.75x60B (D) 2 10 0 N/A 140 51311 4.00" 7 CF375 BCF3907 CF56KZ 2.35 2.00x60B (D) 2 10 2-1/2 N/A 140 51311 4.00" 8 CF375 BCF3907 CF56KZ 2.75 2.25x60B (D) 3 10 3 N/A 140 51311 4.00" 9 CF375 BCF3907 CF56KZ 3.00 2.50x60P 5 10 4 N/A 140 51311 4.00" 9 CF375 BCF3907 CF56KZ 3.33 3.00x45B (D) 5 10 10 N/A 140 51311 4.00" Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. Page 14 Easco Boiler ESP Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue -Low Fire Air or Shutter Red -High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 70 CF2500 BCF1801 CF102KP 21.00 6.00x45P (2) 5 10 50 300 300 51630 5.00" 80 CF3500 BCF1301 CF80KM 24.00 6.50x45P (2) 2 20 80 300 300 51630 5.00" 90 CF3500 BCF1301 CF114KR 27.00 7.50x45P (2) 6 25 85 300 300 51631 5.00" 100 CF3500 BCF1301 CF114KR 30.00 8.50x45P (2) 7 35 95 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. Easco Boiler FST Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue -Low Fire Air or Shutter Red -High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 20 CF800 BCF403 CF100KH 6.00 4.50x45P 3 10 3 N/A 150 51628 5.00" 20 CF1400 BCF205 CF102KE 6.10 3.50x45P 1/2 20 40 150 300 51629 5.00" 32 CF1400 BCF205 CF102KE 9.60 5.50x45P 4 35 70 150 300 51629 5.00" 40 CF2300A BCF304 CF102KG 12.00 6.50x45P 1 17 30 150 300 51630 5.00" 50 CF2300A BCF304 CF102KG 15.60 8.50x45P 4 35 75 150 300 51630 5.00" 60 CF2300A BCF304 CF102KG 18.00 10.00x45P 5 30 60 150 300 51630 5.00" 70 CF2500 BCF1801 CF102KP 21.00 6.00x45P (2) 5 20 50 300 300 51630 5.00" 80 CF3500 BCF1301 CF80KM 24.00 6.50x45P (2) 2 20 80 300 300 51630 5.00" 90 CF3500 BCF1301 CF114KR 27.00 7.50x45P (2) 6 25 85 300 300 51631 5.00" 100 CF3500 BCF1301 CF114KR 30.00 8.50x45P (2) 7 35 95 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. Page 15 Easco Boiler PLW Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue -Low Fire Air or Shutter Red -High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 53 CF2300A BCF304 CF102KG 16.00 9.50x45P 5 30 60 150 275 51630 5.00" 60 CF2300A BCF304 CF102KG 18.00 10.00x45P 7 35 70 150 300 51630 5.00" 66 CF2300A BCF304 CF102KS 19.90 11.00x45P 9 50 100 150 300 51630 5.00" 79 CF3500 BCF1301 CF80KM 24.00 7.00x45P (2) 7 35 85 275 275 51630 5.00" 93 CF3500 BCF1301 CF114KR 28.00 8.00x45P (2) 8 45 95 300 300 51631 5.00" Flange requires an additional adapter plate. Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only. Easco Boiler SM4 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue -Low Fire Air or Shutter Red -High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 20 CF800 BCF403 CF100KH 6.00 4.50x45P 3 10 3 150 N/A 51628 5.00" 32 CF1400 BCF205 CF102KE 9.60 5.50x45P 4 35 70 150 300 51629 5.00" 40 CF2300A BCF304 CF102KG 12.00 6.50x45P 1 16 30 150 300 51630 5.00" 50 CF2300A BCF304 CF102KG 15.00 8.50x45P 4 35 75 150 300 51630 5.00" 60 CF2300A BCF304 CF1...
Эта инструкция также подходит к моделям:Грили - BRYAN STEAM CF1400 (1.2 mb)
Грили - BRYAN STEAM CF1000 (1.2 mb)
Грили - BRYAN STEAM CF2500A (1.2 mb)
Грили - BRYAN STEAM CF3500A (1.2 mb)