Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Aussie, модель pmn

Производитель: Aussie
Размер: 589.64 kb
Название файла: dca889c5-0815-4e7f-bc71-30ee2a67b32b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


6)Hand tighten coupling nut in a clockwise direction. Do not use tools. 7)Mix one cup of water with one cup of dishwashing liquid. 8) Open the valve on LP gas cylinder (Turn the knob on the LP gas cylinder counter-clockwise.) 9)Check for leaks by brushing the soap solution on all LP gas connections and fittings (such as those shown by the heavy arrows in the diagram below.) Make sure you generously brush the locations with the soap solution, completely surrounding the connections and fittings. 10)If “growing” bubbles appear on any of the connection points, then you have detected a gas leak. Immediately close the LP cylinder valve by turning the handle clockwise. A) If leak appears at either end of hose and regulator assembly, retighten the connection at the leak, but do not overtighten. (Note: Only hand tighten at coupling nut) Repeat Leak Test. B) If the leak is coming from the LP gas cylinder, from the valves at the control knobs, or if the leak cannot be stopped, do not use the grill. Call Customer Service at 1-800-251-7558. 11)Turn all control knobs to the “off” position and turn the handle on the LP gas cylinder clockwise until it stops. Disconnect LP gas cylinder by turning coupling nut on regulator in a counter-clockwise direction until regulator is released from threaded LP cylinder gas nozzle. 12)Place the protective cap over LP cylinder gas nozzle. OPERATING THE LP GAS GRILL · Before proceeding, make certain that you understand the Important Safeguards on pages 2 through 4 of this manual. · Before lighting the LP gas grill, you must open the the hood to prevent an explosion from gas build-up. · If your LP gas grill catches on fire: -If the fire is in the grill portion and you can safely reach the control knobs on the control panel, then turn them to the off position. -If the fire involves one of the hoses, and you can safely reach the LP cylinder valve, shut the valve off. - If the fire involves the cylinder, leave it alone, evacuate the area and call the fire department. -If there is any type of fire that threatens either personal safety or endangers property, call the fire department. · If you notice grease or other hot material dripping from the grill onto the valve, hose, or regulator, turn off the gas supply immediately. After the grill has cooled, determine the cause and correct it. After cleaning the valve and hose and regulator assembly, perform a leak test before continuing use. (See Step 10 of Assembly Instructions) · Do not operate an LP gas grill if you have knowledge of or suspect a gas leak. · Never allow children to operate or play near an LP gas grill. Do not leave grill unattended. · Always turn off the LP gas cylinder at the LP cylinder valve when not in use. Allow grill to cool before handling parts or cleaning. · Do not move an LP gas grill when in use or hot. · Never touch hot surfaces. Use heat resistant gloves, long-handled tongs, or cooking mitts at all times since the grill will become very hot. Open the hood carefully when cooking to avoid from the hot air and steam trapped inside. · Do not wear loose clothing (example: hanging shirt tails, clothing with frills, etc.) around a LP gas grill while in use or hot. · Never lean your body over the LP gas grill when lighting it or while it is in use or hot. · This LP gas grill is not designed to be used with a solid plate (griddle.) Full coverage of plates will cause excessive heat and could damage the grill. 30 Preparation Before Cooking · Wash the porcelain or chrome coated Cooking Grids with a mixture of hot water and baking soda. · Empty the grease cup after each cooking session so excessive grease does not accumulate. Failure to remove grease may result in grease dripping onto the cart and/or a grease fire in the tray. Lighting the Grill Using Igniter · Open Hood before lighting the grill to prevent an explosion from gas buildup. · Always inspect the gas hose and regulator assembly before each use. If the hose is cut, damaged, or shows signs of excessive abrasion or wear, do not use the LP gas grill. Contact the manufacturer, as the hose and regulator assembly must be replaced with an assembly specified by the manufacturer prior to further use of the LP gas grill. 3) From the “Off” position, push control knob in on the left side and turn counter-clockwise to the high position. 4) Push the igniter button several times so that it clicks each time. 5) Check to make sure that the burner is lit. 6) Light the remaining half of the burner by turning the control knob counter-clockwise. Your grill has a crossover ignition system that allows the burner to light each side successively. 7) If burners does not light, repeat Step 3. The burner should light within three or four attempts. If burner still does not light, try the right side. WARNING: If both sides of the burner fail to light after following Steps 3 & 4, turn all knobs to the “off” position and close the valve on the LP gas cylinder. Wait five minutes; then repeat all of the ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории