Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Associated Equipment, модель 9407

Производитель: Associated Equipment
Размер: 54.44 kb
Название файла: 5a677c10-70b0-4f95-b787-cf00208ebd44.pdf

Язык инструкции:enesfr

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


However if the clamps are removed while the charger is charging, a spark can occur. It is always best to unplug the charger from the electrical outlet BEFORE removing the clamps from the battery. UPPER BATTERY VOLTAGE LIMITS: The INTELLAMATIC™ charger will not start charging if the battery voltage is above 13.5 volts, this prevents overcharging a battery with a high surface charge. An absolute upper limit of 16 volts has also been included, which applies to 12 volt batteries, and 8 volts for 6 volt batteries. LOW VOLTAGE CHARGING LIMITS: Charging will not begin unless the voltage across the DC output clamps is above 2 volts. If the charger stops after a few minutes (about 3) unplug the charger from the electric outlet for a few seconds, plug the charger back into the electric outlet to begin the charging cycle again. If the charger again fails to indicate charging after a few minutes unplug the charger from the electric outlet and disconnect the DC clamps from the battery. Have the battery checked at a qualified service center. TIME LIMIT ON CHARGING: A charging time limit of 17 hours has been set for added safety. CHARGE COMPLETE SIGNAL: The INTELLAMATIC™ microcomputer checks the battery voltage and monitors the change in voltage with charging time. When the microcomputer determines a full charge the indicator lamp will blink. Output current will be turned off and the lamp will continue blinking until the DC clamps are removed or the charger is unplugged from the electric outlet. It is always best to unplug the charger from the electric outlet BEFORE removing the DC clamps from the battery. EXTENDED BATTERY MAINTAINER: The INTELLAMATIC™ charger is ideal for maintaining batteries while not in use. When charging is complete, the charger will turn off charging current completely with NO TRICKLE charge that could overcharge a battery. If the battery self discharges below approximately 12.6 volts the charger will activate and recharge the battery, a 6 volt battery will restart at 6.3 volts. It is recommended that the battery be checked periodically when charging over extended intervals. ENGINE START - 60 AMPS: The Model 9407 INTELLAMATIC™ charger has a 60 amp engine start feature. When using this feature be sure that the CHARGE/ENGINE STARTER selector switch is set to the CHARGE position when connecting the DC clamps of the charger to the battery. The charger MUST have one minute of charging before attempting an engine start. After this initial charge time you may try an engine start by first setting the selector switch to the ENGINE STARTER position and then turn the ignition key to start the vehicle. A 1.3 second 60 amp burst will help start the engine. If the engine does not start, the battery will need more time to charge. Move the selector switch back to the CHARGE position and allow the battery to charge for a few minutes. There should be a minimum three minute wait between attempts to start, longer periods are recommended. 4 MAINTENANCE INSTRUCTIONS This charger requires minimal maintenance. As with any appliance or tool, a few common sense rules will prolong the life of the battery charger. ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING. 1. Store in a clean, dry place 2. Coil up the cords when not in use. 3. Clean the case and cords with a slightly damp cloth. 4. Clean any corrosion from the clamps with a solution of water and baking soda. 5. Examine the cords periodically for cracking or other damage and have them replaced if necessary. 6. WARNING: All other service should be done by qualified personnel only. NOTES: 5 MODELE 9407 MANUEL D'UTILISATION INSTRUCTIONS DE SECURITE IMPORTANTES 1. CONSERVER CES INSTRUCTIONS. Le present manuel contient des instructions de securite et d'utilisation importantes pour l'utilisation du chargeur achete et qui pourront se reveler utiles ulterieurement. 2. ATTENTION - Afin de reduire le risque de blessures, ne charger que des batteries au plomb rechargeables (6 cellules peu importe l'amperage). Tout autre blessures corporelles et des degats materiels. 3. Ne pas exposer le chargeur a la pluie ou a la neige. 4. L'utilisation d'un accessoire non recommande ou non vendu par le fabricant du chargeur de batterie peut etre la cause d'incendies, d'electrocutions ou de blessures 5. Afin de reduire les risques de dommages a la fiche electrique ou au cordon d'alimentation, debrancher le chargeur en tirant sur la fiche et non sur le cordon. 6. S'assurer que le cordon d'alimentation est place de sorte qu'il ne puisse etre ecrase, accroche ou soumis a toute autre forme de dommages ou de contraintes. 7. N'utiliser de rallonge electrique que si absolument necessaire. L'utilisation d'une rallonge inadequate peut etre la cause d'incendies ou d'electrocutions. necessaire, s'assurer que: a. les tiges de la fiche de la rallonge sont des memes dimension, forme et nombre que celles de la fiche du cordon d'alimentation; b. la rallonge electrique est en b...

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории