Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Avanti, модель BCA244B

Производитель: Avanti
Размер: 240.73 kb
Название файла: rm241b_-_bca244b.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


Remove the exterior and interior packing. . Check to be sure you have all of the following parts: . Instruction manual . Ice Cube Tray – Model RM241B – ONLY . Drip Tray – Model RM241B - ONLY . 2 Refrigerator shelves . Model RM241B – 2 Glass Shelves . Model BCA244B – 2 Wire Shelves . Before connecting the refrigerator to the power source, let it stand upright for approximately 2 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation. . Clean the interior surface with lukewarm water using a soft cloth. • Installation of Your Refrigerator . This appliance is designed to be free standing only, and should not be recessed or built-in. . Place your refrigerator on a floor that is strong enough to support the refrigerator when it is fully loaded. To level your refrigerator, adjust the legs at the front of the refrigerator. . Allow 5 inches of space between the back and sides of the refrigerator, which allows the proper air circulation to cool the compressor. . Locate the refrigerator away from direct sunlight and sources of heat (stove, heater, radiator, etc.). Direct sunlight may affect the acrylic coating and heat sources may increase electrical consumption. Extreme cold ambient temperatures may also cause the refrigerator not to perform properly. . Avoid locating the refrigerator in moist areas. . Plug the refrigerator into an exclusive, properly installed-grounded wall outlet. Do not under any circumstances cut or remove the third (ground) prong from the power cord. Any questions concerning power and or grounding should be directed toward a certified electrician or an authorized Avanti Products service center. . After plugging the appliance into a wall outlet, allow the unit to cool down for 2-3 hours before placing food in the refrigerator compartment. 8 Unit Installation Free Standing Units To ensure not only the efficient operation of your unit but also your safety. When installing your unit follow the steps as shown below: . Place your unit on a flat level surface that is strong enough to support the unit once it is fully loaded. . Your unit is equipped with adjustable height leveling legs to accommodate any minimal changes in the level of the surface on which it is installed. Countertop / Table Top Units When installing units that can be placed on countertops, keep the following in mind: . Surface (countertop) is flat, level, and strong enough to support the unit once it is fully loaded. . Surface is wide enough to accommodate the unit without any overhang. . Surface is deep enough to accommodate the unit when the door is opened to 90. • Electrical Connection .Warning• Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is damaged, have it replaced by an authorized Avanti Products service center. This refrigerator should be properly grounded for your safety. The power cord of this refrigerator is equipped with a three-prong plug which mates with standard three prong wall outlets to minimize the possibility of electrical shock. Do not under any circumstances cut or remove the third ground prong from the power cord supplied. Use of extension cords is not recommended. This refrigerator requires a standard 115/120-volt, 60Hz electrical outlet with three-prong ground. The cord should be secured behind the refrigerator and not left exposed or dangling to prevent accidental injury. Never unplug the refrigerator by pulling the power cord. Always grip the plug firmly and pull straight out from the receptacle. 9 OPERATING YOUR REFRIGERATOR • Setting the Temperature Control • NOTE: If the unit is unplugged, power lost, or turned off; you must wait 3 to 5 minutes before restarting the unit. If you attempt to restart before this time delay, the refrigerator will not start. MODEL RM241B MODEL BCA244B . To control the internal temperature adjust the dial according to the ambient temperature or purpose of use. . The first time you turn the unit on, set the temperature to the coldest setting “6”. . After 24 hours adjust the temperature control the setting that best suits your needs. . The range of the temperature control is from warm “1” to cold “6”. The “0” position turns the cooling cycle off but does not turn off the power to the unit. . The setting of “4” should be adequate for home or office use. . To control the internal temperature adjust the dial according to the ambient temperature or purpose of use. . The first time you turn the unit on, set the temperature to the coldest setting “6”. . After 24 hours adjust the temperature control the setting that best suites your needs. . The range of the temperature control is from warm “1” to cold “6”. The “0” position turns the cooling cycle off but does not turn off the power to the unit. . The setting of “4” should be adequate for home or office use. 10 CARE AND MAINTENANCE • Defrosting Your Refrigerator Defrost the refrigerator when the frost accumulated on the evaporat...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории