Check the fuse has not blown. Appliance cools too much. Temperature is set too cold. Set the temperature to a warmer setting temporarily. The temperature in the refrigerator is too high. Check the ambient temperature is within the appliances operating limits Check the temperature regulator is turned to the correct setting relative to ambient conditions. Warning tone sounds, red warning display is flashing Door is opened for longer than 5 minutes Switch off the warning tone by pressing the ALARM OFF button. Do not leave the door open for longer than necessary. 818 35 69-02/2 Symptom Solution Temperature warning Red warning light flashing, warning tone Please look at “Temperature warning” sounding section. Temperature display shows a square. There is a function fault. Please inform your local Service Force Centre. Do not open the door of the appliance again. Adjust the temperature regulator to give correct temperature control. Check that the door is closed. The compressor runs continuously Large quantities of food have recently been placed in the cabinet and/or door is frequently opened. Check that air ventilation is not obstructed. Ensure the bulb is correctly fitted. The light does not come on. Replace the bulb if it has blown. Check the door light switch is not jammed. Water on the floor or on storage shelves. Water drain hole is blocked. See the "Cleaning and Maintenance" section. Noise Refer to Normal Operating Sounds The compressor does not start immediately after changing the temperature setting. This is normal, the compressor starts after a period of time. If after the above checks there is still a fault, call your local AEG Service Force Centre. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. Please note that proof of purchase is required for in-guarantee service calls. 818 35 69-02/2 Regulations, Standards, Guidelines This appliance was designed for household use and was manufactured in accordance with the appropriate standards. The necessary measures in accordance with appliance safety legislation regulations (GSG), accident prevention regulations for refrigeration appliances (VBG 20) and the regulations of the German Society of Electrical Engineers (VDE) were observed in the manufacture of this appliance. The refrigerant circuit has been checked for leaks. ; This appliance is in accordance with the following EU guidelines: – 73/23/EWG dated 19 February 1973 - low voltage guidelines. – 89/336/EWG dated 3 May 1989 (including guideline change notice 92/31/EWG) - EMV guideline Technical Terminology • Refrigerant Liquids that can be used to a generate a cooling effect are known as refrigerants. They have a relatively low boiling-point, indeed so low, that the warmth from the food stored in the fridge or freezer can cause the refrigerant to boil and vaporise. • Refrigerant Circuit Closed circulation system that contains the refrigerant. The refrigerant circuit comprises primarily of an evaporator, a compressor, a condenser and pipe work. • Evaporator The refrigerant is evaporated in the evaporator. Similar to all other liquids, refrigerant requires heat to evaporate. This heat is removed from the interior of the appliance, as a result the interior is cooled. The evaporator is therefore located inside the appliance or placed in foam immediately behind the inner wall and thus not visible. • Compressor The compressor looks like a small drum. It is driven by a built-in electric motor and is mounted on the base of the appliance at the rear. The task of the compressor is to draw in vaporised refrigerant from the evaporator, to compress it, and to pass it on to the condenser. • Condenser The condenser normally has the form of a grid. The refrigerant compressed in the compressor is liquefied in the condenser. During this process, heat is released to the surrounding air at the surface of the condenser. The condenser is mounted on the base of the appliance. 818 35 69-02/2 Guarantee Conditions Standard Guarantee Conditions We, AEG-Electrolux, undertake that if within 12 months of the date of the purchase this AEG-Electrolux appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials, we will, at our discretion repair or replace the same FREE OF CHARGE for labour, materials or carriage on condition that: • The appliance has been correctly installed and used only on the electricity or gas supply stated on the rating plate. • The appliance has been used for normal domestic purposes only, and in accordance with the manufacturer's operating and maintenance instructions. • The appliance has not been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by us. • All service work under this guarantee must be undertaken by a Service Force Centre. Any appliance or defective part replaced shall become the Company's property. • ...

Эта инструкция также подходит к моделям:
Холодильники - S75578KG3 (754.2 kb)
Холодильники - S75578KG3 (754.2 kb)
Холодильники - S75578KG3 (754.2 kb)
Холодильники - S75578KG3 (754.2 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории