Фрагмент инструкции


With activated carbon filter if exhaust-air mode is not possible. Connecting a l150 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l120 mm exhaust-air pipe: . Screw a reducing adapter onto the air outlet on the hood and then connect the exhaust-air pipe. The complete installation set can be obtained from specialist outlets. 840-1220 mind. 130 300 255 550 33 490 700/900 110 mind. 50 mind. 600 230 600 70 800-1180 Prior to installation Electrical connection Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 18,7 19,2 70 cm 19,3 19,8 90 cm 20,4 20,9 We reserve the right to construction changes within the context of technical development. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals.This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. This extractor hood corresponds to EC regulations concerning RF interference suppression. 23 Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Use the template to mark the points on the wall where the screws will be mounted. In order to make it easier to hook the hood onto the screws, draw the outline of the area where the hood will be attached. Ensure that the minimum distance between the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood. 4. Drill 5 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall. Note: Take into account any special accessories that are going to be fitted. 5. Attach the fixing bracket for the chimney panelling using two hexagon head cap screws. 6. Screw in the middle screw (buttonheaded screw without plain washer) to approx. 5 mm as an assembly aid for the extractor hood fixture. 7. Hook the extractor hood over the screw in the wall. The glass screen must not touch the wall. 23 216 205 439 120 150 mind. 550 Elektro mind. 650 Gas 700/900 600 76 395 ca.5mm 8. Screw in the four hexagon head cap screws with plain washers. Before the 4 screws are tightened down, align the extractor hood properly. If any pressure is exerted on the glass screen when tightening the screws it could lead to glass breakage. 24 Installation 09. Stick protective film over the holes of the 2 lower mounting bolts in the protective grid. 14. Swivel the lower flue duct over the upper flue duct. Warning: The holes in the flue duct must be positioned exactly over the switches. 16. Insert the grease filter (refer to Operating Instructions). 1. 2. 1. 2. P 3 15. Fix the lower flue duct with 2 screws. 10. Connect up the air outlet pipe. 11. Connect the hood to the electricity supply. 12. Remove the protective film from the two flue ducts. Avoid damage to the sensitive surface. 13. Screw the sides of the upper flue duct (slots face down) to the fixing bracket with 2 screws. Mode d’emploi: Description de l'appareil Commutateur Lumiere/ Ventilateur Capot de cheminee Grille du filtre Eclairage Modes de fonctionnement Air evacue a l'exterieur: . Le ventilateur de la hotte aspire les buees de cuisson qui traversent un filtre a graisse avant de regagner l'atmosphere ex...

Эта инструкция также подходит к моделям:
Вытяжки - 3BD896XP/04 (2.59 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории