Производитель: Bosch
Размер: 2.47 mb
Название файла:
|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
There should be no sharp bends. l 100 mm approx. 078 cm2 l 120 mm approx. 113 cm2 If pipes have different diameters: Insert sealing strip. For exhaust-air mode, ensure that there is an adequate supply of fresh air. Exhaust outlet connection: Pipe diameter: 100 or 120 mm. Insert the enclosed outlet connector and twist it as far as it will go. If the pipe diameter is 120 mm, cut out the inner part of the outlet connector. Exhaust air flows upwards: Cut a hole in the top of the wall cupboard, including a groove for the mains cable. – Template OI lis enclosed –. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. Exhaust flows straight out at the back: – inside the wall cupboard –. Cut a hole in the rear panel of the wall cupboard, including a groove for the mains cable. Circulating-air mode With activated carbon filter if exhaust-air mode is not possible. Preparation: Cut a hole in the top of the wall cupboard, including a groove for the mains cable. – Template OI is enclosed –. 180 61,5 196 600 min. 280 200 125 115/130 120 100 257 20 542 500 598 40 450 280 259 32 212 80 75 40 27 Preparing the wall cupboard Ensure that there is a minimum gap between hob and extractor hood of 650 mm (for gas hobs) or 430 mm (for electric hobs). This extractor hood has been designed for installation inside a wall cupboard with the following dimensions: Width: 600 mm Depth: 280 bis 350 mm Height:at least 280 mm. Preparation: 1. Remove bottom panel of cupboard – if fitted. The stability of the cupboard must be maintained. 2. Mark two points – right and left – on the inside of the cupboard where the hood is to be mounted, and start the hole with a gimlet. Details for drilling: l 2 mm – max. 10 mm deep. Use enclosed template OII for marking points where hood is to be mounted. Caution: The mounting points shown on the template have been configured in such a way as to allow a 20 mm thick handle to be attached flush with the front edges of the cupboard. If no handle is going to be attached, the mounting points must be brought forward by 20 mm. If the cupboard depth is greater than 280 mm, the hood can be mounted further back, . . . if the light strip under the cupboard . . . units is mounted further back, . . . if the handle is more than 20 mm thick. To do this, move the mounting points further towards the back by the corresponding distance. 3. Align the 4 enclosed mounting brackets and screw them on tight. 28 Installation inside the wall cupboard 1. Align the cupboard doors if the hinges will no longer be accessible after the extractor hood has been fitted. 2. Place the extractor hood onto the mounting brackets and push it into the cupboard. 4. Install a shelf immediately above the extractor hood. Cut holes for the pipe connection and the mains cable. Important: The extractor hood must be firmly seated on the 4 mounting brackets. 3. Loosely screw in the 4 enclosed screws. Align the extractor hood and then tighten screws. Check that the extractor hood is firmly fitted into the cupboard. 20 20 mind.15 mind. 475 If the shelf is permanently fixed inside the cupboard, 4 holes must be drilled to provide access to the 4 mounting screws for the extractor hood. 5. Route the mains cable through the hole in the wall cupboard and connect up the exhaust pipe. 6. Connect up the extractor hood to the mains. 7. If no handle is going to be attached to the vapour extractor, seal off the 3 holes with the enclosed caps. 29 Installation inside the wall cupboard 8. Cut the wall masking strip down to size if necessary and screw it onto the wall cupboard. 2. Align handle and attach it to the extractor with the 3 enclosed screws. 20 94 230 230 44 598 Attaching a handle to the vapour extractor: A handle can be attached to the vapour extractor. 1. Use the enclosed template OIII to mark the 3 mounting points on the handle and start the hole with a gimlet. Details for drilling: l 2 mm – max. 10 mm deep. Installation inside the wall cupboard Note: The extractor hood housing inside the wall cupboard can be boarded up (e.g. with chipboard). Please observe the following: – The shelf must not be rest upon the extractor hood housing. – The board at the front should not be attached to the housing. – Ensure that access is possible for replacing filters or by Customer Service. Weight in kg: Exhaust air Re-circulating air 7,0 8,0 The manufacturer reserves the right to make design alterations in the interests of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth)...
Эта инструкция также подходит к моделям:Вытяжки - VVA61E150/02 (2.47 mb)
Вытяжки - VVA61E150/03 (2.47 mb)