Фрагмент инструкции


In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. . The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. 1. Press the catch on the grease filters inwards and fold the filters down. At the same time take hold of the underside of the grease filters with your other hand. 2. Clean the filters. 3. Insert the clean filters back into the hood. 4. Cancel the #in the display. . Press the – button. 21 Saturation indicator: b When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 6 seconds after the fan has switched off, and a b appears in the display. The activated carbon filter should be replaced straight away. Replacing the activated carbon filter: . During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x year. . A replacement filter can be obtained from any authorized dealer (see optional accessories). . Use original filters only. By doing so you will obtain maximum performance from your extractor hood. Disposing of the old activated carbon filter: . There are no pollutants in the activated carbon filters. They can therefore be disposed of as part of your normal domestic refuse. Filters and maintenance 3. Engage the catches at both sides. 4. Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 5. Cancel the C in the display. . Press the – button. Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Installation and removal: Warning: The halogen bulbs must be switched off and cool. 1. Remove the metal-mesh filters (see "Removing and inserting the metalmesh grease filters"). 2. Insert the activated carbon filter. Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! . Clean the extractor hood with a hot soap solution or a mild window cleaner. . Do not scrape off dried-on dirt but wipe off with a damp cloth. . When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. . Note: Do not use alcohol (spirit) on plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is adequately ventilated. Avoid naked flames! Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons. Stainless steel surfaces: . Use a mild non-abrasive stainless steel cleaner. . Clean the surface in the same direction as it has been ground and polished. . We recommend our stainless steel cleaner no. 461731. See enclosed service booklet for order address. Aluminium and plastic surfaces: . Do not use dry cloths. . Use a mild window cleaning agent. . Do not use aggressive, acidic or caustic cleaners. Observe the warranty regulations in the enclosed service booklet. Replacing the light bulbs 1. Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box. When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off there is still a risk of burns. 2. Remove the bulb ring with a screwdriver or similar tool. 3. Replace the halogen light bulb (conventional halogen bulb, 12 Volt, max. 20 Watt, G4 cap). Caution: Refer for plug-in lampholder. Take hold of the bulb with a clean cloth. 4. Re-insert the bulb ring. 5. Plug the appliance into the mains or switch it on at the fuse box. Note: If the light does not function, check that the bulbs have been inserted correctly. Setting the saturation indicator If it becomes necessary to change the operating mode (exhaust-air/recirculating mode), the saturation indicator for the filters must also be altered (see Installation Instructions). If you encounter a problem If an # or a appears in the display: . See "Filters and maintenance" Section. If is not possible ...

Эта инструкция также подходит к моделям:
Вытяжки - I89M55N0/01 (3.19 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории