|
Фрагмент инструкции
Changing over from exhaust- air to recirculating mode Changing the electronic control system to recirculating mode: . The electronic control system has been set up in the factory for the mode applicable to the extractor hood version which you have purchased. . If it becomes necessary to change the mode, the electronic control system must also be changed over. Change-over procedure: . The extractor hood must have been connected up and should be switched off. 1. Press and hold the 0 button. 2. While { is displayed, press the button until a or #is displayed. When this has taken place, release the buttons. Changing from exhaust-air to recirculating mode: . a goes out shortly afterwards. The electronic control system will then have been set to recirculating mode. Changing from recirculating to exhaust-air mode: . # goes out shortly afterwards. The electronic control system will then have been set to exhaust-air mode. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly above the chimney panelling in the ceiling. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. In order to replace the mains cable, it is necessary to dismantle the pipe connection piece (undo two screws). If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. This extractor hood corresponds to EC regulations concerning RF interference suppression. Installation This extractor hood is intended to be mounted either directly onto the kitchen ceiling or onto a stable, suspended ceiling structure. See Technical Data for weight of the extractor hood. Ensure that the minimum distance between the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. 1. Mark the centre of the position on the ceiling at which the hood will be mounted. 2. Use the template to mark the position of the holes for the mounting screws. 3. Drill 4 x l8 mm holes and insert plugs into the holes so that they are flush with the ceiling. 4. Assemble the support frame (8 screws). The overall length of the support frame for the standard chimney panelling enclosed with the hood is 565 mm. In the case of longer cover panels, the length of the support frame can be adjusted in steps of 20 mm (from at least 425 mm up to max. of 725 mm for the exhaust-air version and from at least 505 mm up to max. of 725 mm for the recirculating version). 5. Mount the support frame onto the ceiling. . The support frame is marked with "FRONT" on one side. This is side where the switches for the extractor hood will be after installation has been completed. 6. Screw two hex bolts from underneath all the way into the threaded holes in the extractor hood. Screw nuts onto the bolts, leaving a gap of approx. 4 mm. 7. Lift up the extractor hood and hook the protruding nuts into the key-hole slots and secure the hood in place with 2 hex bolts inserted from above into the holes at the corners on the opposite side. 565 310200 346,4175 Installation 8. Screw the extractor hood tightly onto the If the extractor hood is going to be support frame (4 screws). operated in recirculating mode. ca. 4 mm1.2. . Before mounting the chimney cover panels, attach the enclosed adhesive sealing strips around the air outlet slits. . If the extractor hood does not line up properly, loosen the 4 screws in the ceiling and adjust the position within the elongated holes. Following this adjustment, ensure that the screws are tightened again. 9. Connect the air outlet pipe. 10. Connect the hood to the electricity 11. Remove the protective film from the supply. two flue ducts. Take care not to damage the stainless steel surfaces which are susceptible to scratches etc. 12. Insert both sections of panelling into the extractor hood, push them up against the support frame and secure them in ...
Эта инструкция также подходит к моделям:Вытяжки - DKE115A/06 (2.4 mb)