Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Bosch, модель DIA09T850/04

Производитель: Bosch
Размер: 2.34 mb
Название файла:

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста


К этому устройству также есть другие инструкции:

Фрагмент инструкции


¦ An incoming/exhaust air wall box alone will not ensure compliance with the limit. Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or by other technical means. In any case, consult your responsible chimney sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the recirculation mode. a= Risk of fire! from flying sparks. Do not install appliance above a solid fuel heater (e. g. wood or coal) unless a closed, non-removable cover is available. For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers. a= Risk of electric shock! from damaged connection cable. Do not kink or pinch connection cable during installation. a= Risk of injury! From sharp edges during installation. Always wear protective gloves while installing the appliance. a= Risk of injury! from a falling appliance. All safety screws and safety caps must be firmly fitted. 9 Installation Pipe dimensions Note: The device manufacturer does not assume any warranty for complaints attributable to the pipe section. ¦ The device achieves its optimum performance by means of a short, straight exhaust air pipe and as large a pipe diameter as possible. ¦ As a result of long rough exhaust air pipes, many pipe bends or diameters, the optimum extraction performance is not achieved and fan noise is increased. ¦ The pipes or hoses for laying the exhaust air line must consist of non-combustible material. Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended. Flat ducts The inner cross-section must correspond to the diameter of the round pipes. O 150 mm approx. 177 cm2 O 120 mm approx. 113 cm2 ¦ Flat ducts should have no sharp deflections. ¦ Use sealing strip for deviating pipe diameters. Preparing the ceiling ¦ The ceiling must be flat, horizontal and adequately loadbearing. ¦ The depth of the boreholes must be the same length as the screws. The wall plugs must have a secure grip. ¦ The enclosed screws and wall plugs are suitable for solid brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks). ¦ The max. weight of the extractor hood is 50 kg. Attaching upper support frame 1.Before installation, specify the total height of the support frame and mark the screw holes. Note: The height of the support frame can be adjusted in 20 mm steps. 2.On the ceiling mark the centre point of the appliance. 3.Using the enclosed template, mark the positions for the screws on the ceiling. 4.Drill four 8 mm O holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall. 5. Attach the upper part of the support frame to the ceiling with 4 screws. Note: Ensure that the support frame is in the correct position. The middle bracket defines the preferred side and must be facing the hob control. Attaching lower support frame Attach upper and lower parts of the support frame at the specified total height using 10 screws. Notes ¦ Ensure that the lower support frame is in the correct position. The open side must be facing the hob control. ¦ The support frame can be re-aligned by loosening the fastening screws. Installing the appliance 1. Hook the appliance from below into the support frame. Note: Ensure that the mains cable is not trapped. 2. Attach the appliance to the support frame using 2 securing screws. $ %&& ''& ( %&& #&&& 3. Hook in retaining clip and screw tight. Connecting the pipes Note: If using an aluminium pipe, smooth the connection area beforehand. Exhaust- air pipe O 150 mm ( recommended size) Attach exhaust- air pipe directly to the air- pipe connector and seal. Exhaust- air pipe O 120 mm 1. Attach reducing connector directly to the air- pipe connector. 2. Attach exhaust air pipe to the reducing connector. 3. Seal both joints appropriately. Electrical connection a= Risk of electric shock! from damaged connection cable. Do not kink or pinch connection cable during installation. The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal-mesh grease filter. Length of the connection cable: approx. 1.30 m This appliance complies with the EC interference suppression regulations. This appliance may be connected to a correctly installed earthed socket only. Attach the earthed socket preferably inside the flue duct. ¦ The earthed socket should be connected via its own circuit. ¦ If the earthed socket is no longer accessible following installation of the appliance, a disconnector must be fitted as for a permane...

Эта инструкция также подходит к моделям:
Вытяжки - DIB12T151/01 (2.34 mb)
Вытяжки - DIB12T151/02 (2.34 mb)
Вытяжки - DIB12T151/03 (2.34 mb)
Вытяжки - DIB12T151/04 (2.34 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории