Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации Bosch, модель CD53030/08

Производитель: Bosch
Размер: 3.82 mb
Название файла:
Язык инструкции:itenfrdenl
Перейти к скачиванию



Фрагмент инструкции


This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air-intake/ exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. For operating in exhaust-air mode, a one-way flap should be mounted inside the extractor hood unless there is already one fitted in the outlet duct or wall ventilation box. If no one-way flap was enclosed with the hood, it can be obtained from a specialist retailer (see section on optional accessories in the user instructions). 63 Prior to installation 2. Insert the one-way flap into the bearing apertures on the air-pipe connector. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. For optimum extractor hood efficiency: . Short, smooth air exhaust pipe. . As few bends in the pipe as possible. . Diameter of pipe to be as large as possible (ideal is l 120 mm ) and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. 21 32 600 170 133 287 313 195 250 . Round pipes: We recommend Internal diameter at least. 120 mm. . Flact ducts must have an internal cross-section that equates to that of round pipes with a 100/120 mm internal diameter There should be no sharp bends. l 100 mm approx. 078 cm2 l 120 mm approx. 113 cm2 If pipes have different diameters: . Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Exhaust air flows upwards: . Cut a hole in the top of the wall cupboard, including a groove for the mains cable. – Template OI lis enclosed –. mind. 30 115 80 185 120 512 243 269 90 250 32 280 598 280-443 Installing the one-way flap: 1. Cut out the protective grid in the air-pipe connector. Prior to installation Exhaust flows straight out at the back: – inside the wall cupboard –. . Cut a hole in the rear panel of the wall cupboard, including a groove for the mains cable. Connecting the l100 mm exhaust-air pipe: . Cut out the protective grid in the air outlet. . Attach the reducing connector (enclosed or can be obtained from specialist retailers) to the air outlet. Connecting the l120 mm exhaust-air pipe: . Cut out the protective grid in the air outlet. Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. O 100 120 Electrical connection This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood may only be connected to an earthed socket that has been installed according to the relevant regulations. If possible, site the earthed socket directly above the wall cupboard or in its immediate vicinity. . The earthed socket should be connected via its own power circuit. . If the earthed socket is no longer accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. This extractor hood corresponds to EC regulations concerning RF interference suppression. 65 Preparing the wall cupboard Ensure that there is a minimum gap between hob and extractor hood of 650 mm (for gas h...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории