Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Oreck, модель COMPACT AIR PURIFIER

Производитель: Oreck
Размер: 1022.22 kb
Название файла: a8d5b1e3-a3ac-4b8c-ae07-a7e855cd97c0.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This feature gives you an easy, centralized place to wipe away dust. Finally, electronically cleaned air passes back into the room through the top grill. Oreck Air Purifier Placement and Start-Up 1. Your Air Purifier draws in dirty air for cleaning. Place the Air Purifier in a location where the dirty air is not drawn across your head or body while sitting or sleeping. 2. Insert the Charcoal Odor Absorber. The Charcoal Odor Absorber is located with the unit in a separate plastic bag. The Charcoal Odor Absorber snaps into the back of the Collector Cell (see instructions with Charcoal Odor Absorber). Operation Your Air Purifier works best if you leave it in operation continuously, and it provides multiple settings for convenient use at any time. 1. MAIN POWER SWITCH: Turn the unit on by sliding the power switch to the fan speed you prefer (fig. 2): ( • • • ) for maximum cleaning ( • • ) for medium cleaning ( • ) for low cleaning Each setting uses a different fan speed, changing the air flow through the Collector Cell. Regardless of the setting, the Collector Cell will continue to clean the air effectively. 2. POWER INDICATOR LIGHT: The indicator light will glow green when the power is on. NOTE: You may notice an occasional infrequent sharp snapping sound coming from your unit. This is a normal occurrence called “arcing” and results as large particles of dust are collected in the Electronic Collector Cell. Should prolonged or continuous arcing occur, the Electronic Collector Cell should be thoroughly cleaned and dried completely (See “Cleaning Collector Cell”). 2 Instructions WARNING: DO NOT USE THIS ELECTRONIC AIR PURIFIER WHEN OXYGEN TANKS ARE BEING USED OR IN THE PRESENCE OF COMBUSTIBLE GASES. IMPORTANT NOTES: . Place or mount the Air Purifier near a standard electrical outlet. Do not block either the air intake or outlet grill. . Never place your Air Purifier on soft surfaces (such as bed, sofas or carpet), near computers or next to sources of heat (such as stove tops, ovens, etc.) . Make sure the front grill is securely locked in place. . A safety switch is installed behind the grill of your electronic Air Purifier. If the grill is not properly secured in place, the unit will not operate. If your unit fails to operate, remove the front grill and reinstall it, being sure that the lower right-hand side of the grill (next to the control panel) is firmly locked in place. . Plug the power cord into the nearest available standard electrical outlet. (See data label on bottom of your Air Purifier for electrical specifications and power consumption.) . Do not use an extension cord to supply power to your Air Purifier. Cleaning The Cabinet You can clean the Air Purifier cabinet with mild, non-abrasive cleanser and a soft cloth. IMPORTANT: Unplug the unit from its electrical power source. Do not spray cleansers or furniture polish into louvers or grill areas. Collector Cell IMPORTANT: Do not try to clean the Collector Cell by inserting a cloth, brush, or other device between the cell plates. The Collector Cell should be cleaned with Oreck’s Assail-A- Cell® cleaner or using soap and water (see Step 6. in this section). Inserting objects in the Collector Cell may damage it. Oreck recommends cleaning the Collector Cell every four to eight weeks, or more often if snapping becomes frequent. Cleaning your Oreck Air Purifier is a snap too... and a must for efficient operation. To clean proceed as follows: 1. Turn the unit off and unplug it from the electric power source. If wall mounted, remove unit from wall. 2. Remove front grill by pressing both buttons under the grill on the cabinet bottom (fig. 3). 3. Pull the Collector Cell out of the cabinet by using the two small handles on the front of the Cell (fig. 4). 4. Snap off the Charcoal Odor Absorber from the back of the Collector Cell. Change as necessary for continued odor removal (fig. 5). 5. Slide off Pre-Filter. The permanent filter should be rinsed off and reused (fig. 6). NOTE: Handle the Electronic Collector Cell with care. Damaged metal plates and/or broken wires will cause the Air Purifier to malfunction. (Do not wash Charcoal Odor Absorber; it is disposable.) 4 3 Buttons 4 Whenever calling, please be sure to have your model and serial number from data plate. CALL CUSTOMER SERVICE HOT LINE US:1-800-989-3535 Canada: 1-888-676-7325 Accessories (Sold Separately) ITEM PART # 1. Pre-Filter 7780-8040 2. Ionizer/Electronic Collector Cell 5510-7064 3. Charcoal Odor Absorber (Set of 4) AT4PK7 4. Oreck’s Assail-A-Cell® cleaner 32358 USA: 800-989-3535 Canada: 888-676-7325 Outside the USA and Canada, contact your local Oreck Distributor. 5 6 Replacing Cell After Cleaning 1. Snap in the Charcoal Odor Absorber (fig. 5). 2. Slide in the Pre-Filter (fig. 6). 3. Slide Collector Cell into cabinet, using handles (fig. 4). 4. Replace front grill. Unit is now ready for operation (fig. 3). NOTE: An occasional snapping or popping sound (“arcing”) is normal when operating the unit imme...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории