IMPORTANT: Unplug the unit from its electrical power source. Do not spray cleansers or furniture polish into louvers or grill areas. Cleaning the Electronic Collector Cell IMPORTANT: Do not try to clean the Collector Cell by inserting a cloth, brush, or other device between the cell plates. The Collector Cell should be cleaned with Oreck’s Assail-A-Cell® cleaner or using soap and water (see Step 6, in this section). Inserting objects in the Collector Cell may damage it. Indicator light is green under normal operation and flashes red when the Collector Cell requires cleaning. The red "WASH CELL" light will flash or illuminate when it is time to clean your Collector Cell. Your Air Purifier is still filtering the air when the red light illuminates. It is not necessary to wait for the red "WASH CELL" light before cleaning the Collector Cell. Even if the “WASH CELL” light is not red, Oreck recommends cleaning the Collector Cell every 4 to 8 weeks, or more often if snapping becomes frequent. Cleaning your Oreck Air Purifier is a snap too... and a must for efficient operation. To clean proceed as follows: 1. Turn the unit off and unplug it from the electric power source. If wall mounted, remove unit from wall. 2. Loosen the front grill retainer screw at the front of the cabinet bottom. Press in the lock (half-moon) on the left side and remove the grill (fig. 3). 3. Pull the Collector Cell out of the cabinet by using the two 4 3 4. Snap off the Charcoal Odor Absorber from the back of the Collector Cell. Change as necessary for continued odor removal (fig. 5). 5. Slide off Pre-Filter. This can be cleaned with the Collector Cell and reused (fig. 6). NOTE: Handle the Electronic Collector Cell with care. Damaged metal plates and/or broken wires will cause the Air Purifier to malfunction. (Do not wash the disposable Charcoal Odor Absorber.) 6. Oreck’s Assail-A-Cell® cleaner is an excellent way to clean an Electronic Collector Cell. Be sure to spray between each cell plate and cover every surface. Allow product to soak for a few minutes, not allowing it to dry. Rinse thoroughly with water. For extremely heavy deposits, repeat the process. If you prefer not to use Oreck’s Assail-A-Cell® cleaner, you may also decide to soak the Electronic Collector Cell in warm water in a kitchen sink or bathtub. Mild dish detergent (powder or liquid) may be added to the water to help break down the dirt on the Collector Cell. The Collector Cell should be allowed to soak for two to three hours. Tobacco smoke (tar) is especially hard to remove from the Collector Cell. If the Purifier has been cleaning tobacco smoke, the Collector Cell may need to soak longer, or it may need to be cleaned a second time. In either case, the Collector Cell should be allowed to air dry before re-inserting it. Oreck does not recommend the use of heated or compressed air as part of the drying process. 5 6 5 6 5 IMPORTANT: Dry the Collector Cell thoroughly outside of the Air Purifier before reinstalling it into the Air Purifier. Ensure that all areas including corners and areas that may trap water are dry before reinstalling into the Air Purifier. If the power indicator light is red after replacing Collector Cell, then the Collector Cell is still wet. Remove Collector Cell and allow it to finish drying Replacing The Charcoal Odor Absorber (Optional) In addition to air purification, your Oreck Air Purifier provides the additional benefit of odor removal. The odor removal function is optional. Your Oreck Air Purifier will continue to remove harmful airborne particles with its permanent Electronic Collector Cell even if you choose not to use the optional Charcoal Odor Absorber. Odor absorption effectiveness will gradually deteriorate over time unless the Charcoal Odor Absorber is replaced. While every environment is different, Oreck suggests that the Charcoal Odor Absorber be replaced every two months or as needed. IMPORTANT: DO NOT wash the Charcoal Odor Absorber. Replace, if necessary. Replacing Collector Cell After Cleaning Replacing Fragrance Cartridge 1. Open Fragrance Cartridge compartment by sliding the Fragrance compartment release switch (fig. 7). 2. Remove Fragrance Cartridge from center of the compartment and replace with a new one (fig. 8). 3. Close compartment until it locks (fig. 9). NOTE: One Fragrance Cartridge is included. 9 7 8 1. Snap in the Charcoal Odor Absorber (fig. 5). 2. Slide in the Pre-Filter (fig. 6). 3. Slide Collector Cell into cabinet, using handles (fig. 4). 4. Replace front grill. Unit is now ready for operation (fig. 3). NOTE: An occasional “arcing” sound is normal when operating the unit immediately after cleaning the Cell and should stop after a few minutes of operation. 6 ACCESSORIES & TROUBLESHOOTING ACCESSORIES & TROUBLESHOOTING Troubleshooting Guide Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing the chart below. It pinpoints problems and how to correct them. ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории