Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Aprilaire, модель 4200

Производитель: Aprilaire
Размер: 1.03 mb
Название файла: Owners_Manual_4200_4400_Form_10007821.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Allergies (24 hour cycle): When seasonal allergies spike and outside air quality is at its worst, choose this option to run your air cleaner continuously for 24 hours then turn off. Bars are added to the filter life indicator section of the display in increments until it is time to change the filter, at which time all the bars will flash. Your filter will generally last a year, but this depends on a number of factors including your environment, construction details, pets, how often you run your air cleaner and of course personal choice. Because the life of the filter is dependent on so many factors, the amount of time between filter changes is selectable. To change the setting (see Figure 4): 1. Remove the front of the Air Cleaner Control from the base. 2. Move the jumper to the desired position. 3. Replace the front of the Air Cleaner Control on to the base. OFF Filter change frequency is once per year A, B & C If you run your fan continuously, these settings will result in filter change reminders more frequently than once per year (A = 9 months, B = 6 months, C = 3 months). If you do not run your fan continuously, these settings can be used to have the filter change reminders optimized to what you feel is best for your home (A is less frequent, C is more frequent). Again, how often you should change your filter is dependent on a number of factors, and a little experimenting may be required to set it to your optimum change frequency. MAINTENANCE FILTER LIFE INDICATOR – SETTING THE REPLACEMENT FREQUENCY Jumper FIGURE 4 TABLE 2 – Filter Change Frequency Jumper Position Filter Change Setting OFF One calendar year (365 days) A 6570 hours of use B 4380 hours of use C 2190 hours of use 90-1338 5 When the last bar on the Filter Life Indicator section of the display fills up, this section of the display will flash. 1. Replace the filtering media with genuine Aprilaire SelfSeal™ filters, available from your installing contractor. IMPORTANT: Follow the step by step directions on the filter carton to ensure that it is installed in the proper orientation – the outlet side of the filtering media is the expanded metal. • Use Model 213 filtering media for the Model 4200 Air Cleaner. • Use Model 413 filtering media for the Model 4400 Air Cleaner The model number for your air cleaner can be found on the door label (see Figure 5). Record this information on your replacement record found on the following page. 2. Press and hold the Filter Reset button for 5 seconds (see Figure 6) and the Filter Life Indicator section of the display will return to the “NEW” condition. CHANGING THE FILTER When “REPLACE BATTERY” appears on the display, remove the battery cover (see Figure 7) and replace both AA alkaline batteries. REPLACE BATTERY Press here, then pull off battery cover MAINTENANCE (CONTINUED) 90-1340 90-1339 FIGURE 6 FIGURE 7 – Open Battery Compartment FIGURE 5 90-1334 Air Cleaner model number found here Aprilaire Air Cleaners are so effective at removing particles and contaminants that are harmful to your family and your HVAC equipment, we offer you this guarantee. Should your new indoor air conditioning coil require professional cleaning in the next 10 years while properly using an Aprilaire Air Cleaner, we will pay $100 toward the cost of having the indoor coil cleaned by a licensed contractor. This commitment applies to new HVAC equipment with a new indoor air conditioner coil (less than six months old) installed with an Aprilaire Air Cleaner. The Aprilaire Air Cleaner must be installed by a licensed HVAC contractor. The Aprilaire Air Cleaner must be properly maintained as per directions in the owner’s manual including use of only Aprilaire brand media replacement. For redemption details, please visit or call 1-800-334-6011. APRILAIRE 10 YEAR CLEAN COIL COMMITMENT 6 FILTERING MEDIA REPLACEMENT RECORD Check one: Air Cleaner Model 4200, Replacement Filter Media Model 213 Air Cleaner Model 4400, Replacement Filter Media Model 413 Date Dealer Name LIMITED WARRANTY LIMITED WARRANTY Your Research Products Corporation Aprilaire Media Air Cleaner is expressly warranted for five (5) years from the date of installation to be free from defects in materials or workmanship, except, however, for the disposable media which will have to be replaced from time to time depending upon the use, and the inner housing seals. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any part of the Media Air Cleaner which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you or your original supplier to Research Products Corporation, Madison, WI 53701, together with the model number and installation date of the Media Air Cleaner. THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP ...

Эта инструкция также подходит к моделям:
Воздухоочистители - 4400 (1.03 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории