Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Honeywell, модель F115

Производитель: Honeywell
Размер: 194.24 kb
Название файла: 89d54db5-9efe-4cd0-bf1d-f1abb6ef6628.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The air cleaners are designed for use in restaurants, conference rooms, lounges and offices where overhead air cleaning is required. They provide their own air circulation, so the air cleaners can be used in any situation that requires the reduction of contamination from an enclosed area. PRODUCT DATA FEATURES • High Efficiency Particulate AIR (HEPA) filter models are 99.97% efficient and the D.O.P. particle filter models are 95% efficient at 0.3 micron particles. Both models are more efficient on particles smaller and larger. • F114 two-speed, direct-drive, forward curve, motor/blower models deliver up to 325 cfm (550 m3/hr). • F115 single speed models deliver up to 600 cfm (1020 m3/hr) . • Select models include CPZ™ disposable canisters for odor control. • Light colored covers complement the ceiling finish. • Available in 120 Vac, 60 Hz or 220-240 Vac, 50/60 Hz models. • READ AND SAVE THESE INSTRUCTIONS Contents General .............................................................................. 1 Features ............................................................................ 1 Specifications .................................................................... 2 Ordering Information ......................................................... 2 Planning the Installation ................................................... 3 Installation ......................................................................... 4 Operation ........................................................................... 5 Service ............................................................................... 5 Parts List ........................................................................... 6 Warranty ............................................................................. 10 The Honeywell Trademark is used under license from Honeywell Intellectual Properties, Inc. by Air-Pure Systems. Honeywell International Inc. makes no representations or warranties with respect to this product. 68-0201-2 Revised 11-07 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Models: SPECIFICATIONS Refer to Table 1 for model descriptions. IMPORTANT Color: The specifications given in this publication do not F114: white cabinet and cover. include normal manufacturing tolerances. Therefore, F115: white cabinet and cover. this unit may not exactly match the listed specifications. This product is tested and calibrated Blower/Motor: under closely controlled conditions, and some minor F114: two-speed, direct-drive, forward curve. differences in performance can be expected if those F115: single-speed, direct-drive, forward curve. conditions are changed. Table 1. F114 and F115 Description. Efficiency Particulates at 0.3 Approximate CPZ™ Air Volume in cfm Model Voltage Micron (D.O.P. Test) components in pounds (m3/hr) F114A 120 Vac, 60 Hz, 1PHS, 3.6A 99.97% HEPA N/A HI = 325 (550); LOW = 180 (306) 220-240 Vac, 60 Hz, 1PHS, 1.7A 99.97% HEPA NA HI = 325 (550) LOW = 180 (306) F114C 120 Vac, 60 Hz, 1PHS, 3.6A 95% 7 HI = 350 (595); LOW = 200 (340) 220-240 Vac, 50/60 Hz, 1PHS, 1.7A 95% 7 HI = 320 (544); LOW = 165 (280) F115A 120 Vac, 60 Hz, 1PHS, 7.2A 99.97% HEPA N/A 600 (1020) 220/240 Vac, 60 Hz, 1PHS, 8.6A 99.97% HEPA N/A 600 (1020) F115C 120 Vac, 60 Hz, 1PHS, 7.2A 95% 12 600 (1020) 220/240 Vac, 50/60 Hz, 1PHS, 3.6A 95% 12 550 to 600 (935 to 1020) aNot applicable. ORDERING INFORMATION If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Commercial Air Products Distributor. 2. Air-Pure Systems 16873 Fish Point Rd. SE Prior Lake, MN 55372-1714 Phone: (800) 998-1919 Fax: (800) 221-3248 68-0201-2 Revised 11-07 2 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Dimensions: See Fig. 1 and 2 for dimensions. M12735 37-1/2 (952) 28-7/8 (733) 1-1/4 (31) POWER INPUT POINT3/8 IN. (10) DIAMETER MOUNTING HOLES (2) 34-1/8 (867) 10 (254) 4-3/4 (120) 16-1/8 (410) 20 (508) Fig. 1. Approximate dimensions ofF114 in in. (mm). 3/8 IN. MOUNTING HOLES (4) 16 (406) 34-3/4(859) 28-7/8 (724) 34-3/4 (859) POWER INPUT POINT POWER INPUT POINT 9-3/4 (248) M11688 Fig. 2. Approximate dimensions ofF115 in in. (mm). Installation Weight: F114: approximately 40 lbs (18 kg). F115: approximately 80 lbs (36 kg). Controls: F114: two speed On/Off switch. F115: direct wired (optional remote mounted On/Off switch). Sound Level at 3.3 ft (1m): F114: 59 dBA on High speed, 55 dBA on Low speed. F115: 52 to 56 dBA. Replacement Parts and Accessories: See Parts List on page 8. PLANNING THE INSTALLATION WARNING Electrical Shock Hazard. Power source can cause personal injury. • Do not damage electrical wiring or hidden utilities when cutting or drilling into the wall or ceiling. • Do not install where the media air cleaner can be reached from a tub or shower. • Always turn off the power at the service panel. Lock the panel to prevent the power from being...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории