|
Фрагмент инструкции
Likewise, if the selection box is at the top of the screen and key is pressed, the selection box moves to the bottom of the screen. "+" and "–" keys The "+" and "–" keys are used to move to the right and to the left within the selection box. If the function selected is temperature, these keys are used to increase and reduce the desired temperature as shown below: 32 33 Navigation Instructions for Use Installing the air expulsion tube Fit the air expulsion tube onto the fixture with the “push” tab and thread it anti-clockwise, Fig. 6. Housing for the air expulsion assembly Fig. 6 If easier, the housing can also be removed from the appliance by pressing the “Push” tab and sliding it out, Fig. 7. Once out, thread the expulsion tube as shown on Fig. 8, making sure that it is properly secured. Fig. 7 Preparing the appliance Fig. 8 Fig. 9 Then fit the assembly onto the appliance by slotting it into position Fig. 9. Securing the diffusion duct onto the air expulsion tube Fit the diffusion duct onto the free end of the tube pushing both parts gently until the duct clicks into place. Make sure that the clips are closed. Otherwise, the duct may fall off. .......... Fig 10. Fig. 10 .clac! 34 Installing the air expulsion accessories for the air-conditioning function There are a set of accessories used to expel hot air (see "Description of accessories"). Installation for the dehumidification and air purification function . Remove the diffusion duct and set the air expulsion tube to the position shown in fig. 11. . The expulsion tube may also be totally dismantled if desired. Fig. 11 Instructions for Use Installing the suction pad . Open the window slightly and position the diffusion duct between the jamb and the glaze frame. . Close the window as far as possible and secure it with the suction pad supplied, Fig. 12. Fig. 12 Installing the sliding window / balcony accessory . The sliding window/balcony installation accessory supplied with your appliance can also be used (See "Description of accessories"), Fig. 13 : a, b, c, d. This accessory can be used for both horizontal and vertical windows. a b c d Fig. 13 . The accessory has two holes on the side to fit it to the window / balcony with. The user can secure it to the frame or wall with two screws (not included with the accessory) to prevent it from moving or falling out of place, Fig. 14. 35 Instructions for Use . Remove the diffusion sleeve and connect the air expulsion tube to the accessory. Fig. 14 Permanent installation Performed using the wall grommet accessory. See "Description of accessories". . To expel hot air through the wall, it is necessary to make an 14-cm diameter hole in the wall and fit the wall grommet, Fig. 15. 24 - 38 cm. Fig. 15 Notes Do not extend the hot air expulsion tube more than necessary (maximum length; 140 cm). Do not form sharp bends when positioning the tube, otherwise the correct expulsion of hot air may be impeded. This may cause a reduction in the cooling power and performance of the appliance. In order to achieve maximum cooling efficiency and minimum noise levels, the expulsion tube should be fitted above the total height of the appliance, Fig. 16. 90° 0° Fig. 16 Turning the appliance on and off Press the "On" / "Off" key to start the appliance. Warning! Make sure that the appliance is plugged into the mains electricity supply. Selecting the operation function The following functions can be selected on your appliance: . cooling . . dehumidification . . air purification . Instructions for Use symbol press the handle and remove the tank drain. on the appliance properly. Warning! turned off, it is necessary to wait for approximately 3 minutes before the appliance operation. Dehumidification . Turn the appliance on by pressing the "On" key . Fig. 17 Cooling In this function, the appliance reduces ambient temperature until the desired temperature is reached. The appliance dehumidifies and purifies the air in the room at the same time in order to create a pleasant atmosphere. . Plug the appliance into the mains electricity supply. . Lead the hot air expulsion tube outside, (see "Preparing the appliance before use"). . Check that the plug is fitted onto the water drainage pipe to prevent water from leaking onto the support surface. . Lift the air director on the top of the appliance, Fig. 17. Place the selection box on the operation function menu using the "up" and "down" keys (see "Navigation": “up“ and "down" keys). Use the "+" and "–" keys to move within the selection box and select the desired function (see "Navigation": "+" and "–" keys). . Select the cooling function , (see "Selecting the operation function"). . Select the desired temperature, (see "Selecting the temperature"). If the appliance turns itself off automatically because the desired temperature for the room has been reached, it will not start working again until ambient temperature rises 2-3°C. . Select the operation speed, (see "Selecting the speed"). During air condition...
Эта инструкция также подходит к моделям:Воздухоочистители - PAM0740/02 (7.18 mb)