Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации Bosch, модель AW280120/01

Производитель: Bosch
Размер: 945.23 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


1 GAS Abb. 1 ELECTRIC Table of Contents Operating Instructions Installation Instructions Operating modes 4 Important information 15 Exhaust-air mode 4 Circulating-air mode 4 Prior to installation 16 Coanda effect 5 Exhaust-air mode 16 Circulating-air mode 17 Operating for the First Time 6 Preparing the wall 18 If you encounter a problem 6 Electrical connection 19 Safety instructions 7 Installation 20 Operating procedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn 13 Operating modes Exhaust-air mode • Installation accessories for exhaust air mode. Ventilation duct AD280/281-012 for ceiling heights of 2.25–2.62 m AD280/281-022 for ceiling heights of 2.62–3.01 m. • The extractor-hood fan extracts the kitchen vapours and conveys them through the grease filter into the atmosphere. • The grease filter absorbs the solid particles in the kitchen vapours. • The kitchen is kept almost free of grease and odours. When the extractor hood is operated in exhaust- air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air-intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. Circulating-air mode • Installation accessories for circulating air mode. Ventilation duct AD280/281-112 for ceiling heights of 2.36–2.62 m AD280/281-122 for ceiling heights of 2.62–3.01 m. • An activated carbon filter must be fitted for this operating mode (see Filters and maintenance). • The extractor-hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen. • The grease filter absorbs the grease particles in the kitchen vapours. • The activated carbon filter binds the odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours. Coanda effect • You do not need to activate the Coanda effect. The Coanda air flow is always active at every fan level. Cooking vapours are extracted particularly well at the front of the cooking field. • The Coanda effect may allow you to operate the extractor hood at a lower, quieter level than you were previously accustomed to. • The Coanda air flow exits the top of the extractor hood’s front panel. Do not place any objects on the extractor hood: these may disrupt the Coanda effect. Operating for the First Time The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. This extractor hood complies with all relevant safety regulations. Repairs should be carried out by qualified technicians only. Improper repairs may put the user at considerable risk. Before using your appliance for the first time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance. Please retain the operating and installation instructions for a subsequent owner. This appliance is labelled in accordance with European Directive 2002/96/EG concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU. If you encounter a problem If an F appears in the display: • See "Filters and maintenance" Section. If is not possible to operate the extractor hood: • Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box. Wait for approx. 1 minute and then switch it on again. If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the fo...

Эта инструкция также подходит к моделям:
Воздухоочистители - AW280190/01 (945.23 kb)
Воздухоочистители - AW281120/01 (945.23 kb)
Воздухоочистители - AW281190/01 (945.23 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории