Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Bionaire, модель BAP1250-U

Производитель: Bionaire
Размер: 420.27 kb
Название файла:
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


NIGHTLIGHT Your EnviroCheckTM Wireless Air Quality Center has a built in nightlight which automatically turns on as your room gets dark. To turn off this nightlight press the "+" and "-" buttons at the same time. To turn this function back on simply press both buttons again. NOTE: When any button is pressed the backlight will come on for a few seconds. Once no buttons are pressed again for 5 seconds the light will go off. Air Quality Sensor Your Bionaire® Air Cleaner comes with an Air Quality Sensor which uses an advanced infrared optical system to constantly detect tiny particles in the air around the EnviroCheckTM Wireless Air Quality Center such as pollen and dust. It also displays the air quality even when the air cleaner is turned off, using a series of colored lights. Radio frequency technology sends continuous signals between air cleaner and the EnviroCheckTM Wireless Air Quality sensor and adjusts air cleaner to improve air quality wherever it is placed. • The air quality sensor uses a series of lights to indicate air quality conditions and particle levels. The lights range in color from green which indicates good air quality conditions or low levels of airborne particulate to red which shows poor air quality conditions or high levels of airborne particulate. • The air quality sensor operates continuously when the EnviroCheckTM Wireless Air Quality Center is plugged into a 120V AC outlet, even when the air cleaner is turned off. Sensor Control Mode When the EnviroCheckTM Wireless Air Quality Center is in the “Sensor Control” mode, it will automatically adjust the fan setting to the optimum speed based on the air quality conditions and particle levels in the air. As the particle concentration in the air rises, so does the speed. In sensor control mode, the unit will always run at a minimum of SLEEP speed even if the particle levels are low to maintain ideal conditions. 1. To turn the air cleaner onto “Sensor Control” mode you must use the EnviroCheckTM Wireless Air Quality Center. 2. Turn the air cleaner on using the Operating Instructions. Select the desired operating speed by scrolling through the settings using the “MODE” button. You can select from “HI”, “MED”, “LOW”, “SLEEP” or “Sensor Control”. 3. Once in “Sensor Control” mode, the air cleaner speed will fluctuate depending on airborne particulate concentration. NOTE: The Sensor Control mode can not be controlled from the air cleaner control panel. It can only be controlled using the EnviroCheckTM Wireless Air Quality Center. CLEANING/MAINTENANCE INSTRUCTIONS Air Cleaner Maintenance Instructions Turn off and unplug the unit before cleaning. 1. The outside of the air cleaner can be cleaned with a soft, damp cloth. 2. The filtered air outlet/top air vent can be cleaned of dust with a small, soft brush. 3. You can remove the air inlet/front grill for cleaning by open the door of the air cleaner. Carefully placing fingers in the indentation on the right side of the door and gently pull forward. With door open to 90 degrees pull grill up and forward. Once removed front grill can be cleaned with warm soapy water. Do not place in dishwasher. Make sure the grill is completely dry before reinstalling. (Figure 3) 4. If you wish to clean the inside of the air purifier, please remove filters and only use a dry, soft cloth to wipe it down. 5. DO NOT wash HEPA or CARBON filters. WARNING: Do not allow moisture to come in contact with the main housing of the air cleaner. Pre-Filter Cleaning Instructions 1. Every 2-3 weeks check the conditions of the washable foam pre-filter. 2. Open the front door and remove the pre-filter frame to examine the pre-filter. (see figure 3) 3. If the pre-filter has a noticeable amount of dust, lint or particulate accumulation, wash it by hand in warm soapy water. The pre-filter must be washed at least every 30 days or more often as necessary. If the pre-filter is worn or damaged replace it. DO NOT wash in an automatic washer. Gently hand wash only. 4. After washing, rinse and dry the pre-filter thoroughly before replacing it into the air cleaner door. DO NOT dry the pre-filter in an automatic dryer. Hand dry only by dabbing gently with a hand dry cloth towel. 5. Replace pre-filter in door and latch pre-filter frame (see figure 4). Filter Life Indicators The HEPA Filter life indicator uses a series of lights to give you an indication of the remaining filter life. With new filters, the lights on the air cleaner display will be illuminated green. As filter life progresses the filter life indicator will move to yellow. When the filter light is red, it is time to change the HEPA filters. There is also a carbon filter indicator light on the air cleaner control panel. When this light illuminates red, it is time to change the Carbon filters. FILTER REPLACEMENT INSTRUCTIONS On average, HEPA filters need to be replaced every 12-18 months. Carbon filters need to be replaced every 3-6 months. Filter life will vary depending on air quality and...

Эта инструкция также подходит к моделям:
Воздухоочистители - BAP1225-U (420.27 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории