Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Scotsman Ice, модель Air and Water Cooled C1448

Производитель: Scotsman Ice
Размер: 2.58 mb
Название файла: User48aw.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


which provides the user with the information to use When desired, optional controls can add features the product; and Maintenance, which provides the like ultrasonic bin ice level sensing, seven day user with the information needed keep it operating programmable bin ice level setting, remote lock out efficiently. and more. Table of Contents Installation:ProductSpecifications.................................... Page2 ProductInformation............................................ Page3 ProductDescription&ElectricalRequirements .............................Page4 Water ...................................................Page7 PanelRemoval ..............................................Page8 UncrateandSetUp ...........................................Page9 PlumbingRequirements .........................................Page10 Drains................................................... Page11 Electrical .................................................Page12 FinalCheckList .............................................Page13 InitialStartUp ..............................................Page14 Adjustments ...............................................Page15 Waterflushsetting ............................................Page16 UseandOperation ............................................Page17 Switches .................................................Page18 OptionsandOtherInformation ......................................Page19 Cleaning,SanitationandMaintenance.................................. Page20 Aircooledcondenserfilter ........................................Page22 Whattodobeforecallingforservice ................................... Page23 Note any Caution or Warning symbols when they appear on the product or in this manual. They indicate potential hazards. November 2006 Page 1 Installation: Product Specifications Location Limitations: The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge very warm air into the room out the back. Space must be allowed at the left side and back for air intake and discharge. Water cooled models discharge warm water into the building’s drain. Space needs to be provided on both sides and above for service access. Space Limitations Note: Although the machine will function, ice capacity of air cooled machines will be significantly reduced with minimal clearance at the sides, back and top. Some space is recommended for service and maintenance purposes on all models. 6" of space at the sides and back are required for adequate operation. To get the most capacity, locate the machine away from heat producing appliances and heating ducts. Provide several feet of space to the left for maximum ice capacity. Walls or other large machines near to the ice machine might also cause a reduction in ice capacity. One foot behind and two feet above will be required to make rated capacity. Airflow is in the front, in the left side, out the back (as viewed from the front). Environmental Limitations Minimum Maximum Air temperature 50oF. 100oF. Water temperature 40oF. 100oF. Water pressure 20 psi 80 psi Power supply – acceptable voltage ranges Minimum Maximum 208-230 volt model 198 volts 253 volts Warranty Information The warranty statement for this product is provided separately from this manual. Refer to it for applicable coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance, corrections to installations, or situations when the machine is operated in circumstances that exceed the limitations printed above. November 2006 Page 2 C1448, C1848, C2148W Air and Water Cooled User Manual Airflow Direction C1448, C1848, C2148W Air and Water Cooled User Manual Product Information The product is a modular cuber. That type of machine is designed to be placed on an ice storage bin or an ice dispenser. Many installations only require the matching bin, but some also require an adapter to be placed between the bin and the cuber or between the dispenser and the cuber. This product cannot be stacked. See the chart for application information. Model Number Description Example: • C1448SA-32A • C= cuber • 14= nominal ice capacity in 100s of pounds • 48= nominal width of cabinet • S= Cube size. S=small or half dice cube. M=medium or full dice cube • A=Condenser type. A=air cooled. W=water cooled • -32=Electrical code. -32=208-230 single phase. -3=208-230 three phase • A=Series revision code. A=first series Note: In some areas of this manual model numbers may include only the first five characters of the model number, meaning that the cube size, condenser type and voltage differences are not critical to the information listed there. Options: There are several field-installed options that can be installed at initial start up or later. They include: • KVS -Vari-Smart. adjustable ice level system. • KSB -Smart-Board. advanced feature control. • A39515-021 air baffle to reduce air recirculation around the back of the cabinet when install...

Эта инструкция также подходит к моделям:
Воздухоочистители - Air and Water Cooled C1848 (2.58 mb)
Воздухоочистители - Air and Water Cooled C2148W (2.58 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории