Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Holmes, модель HAP240008EM1

Производитель: Holmes
Размер: 542.68 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• This may occur more frequently when the filter is nearing the end of its useful product life and unable to capture as many charged particles. • Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filter and interfere with the ionization process. To help prevent particles from attracting to surfaces throughout your home: • You may want to run the ionizer less often. • Check the condition of the filter more frequently. CAUTION: The ionizer in this appliance produces less ozone than the UL* established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on. HEPA-TYPE FILTER HEPA-type (High Efficiency Particulate Air) filters are designed to remove up to 99% of airborne pollutants, at 2 microns or larger, from the air that passes through them. These include tobacco smoke, household dust, pet dander and pollen. HIGH, MEDIUM AND LOW SPEEDSETTINGS For optimum air filtration, operate your Holmes® air purifier continuously on the MEDIUM (II) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select LOW (I) setting. When high levels of air pollution are present, select the HIGH (III) setting to quickly circulate and filter the room air. FILTER REMINDER DIAL This convenient feature helps you keep track of when to change the filter. *Tested and listed by the Underwriters Laboratories, Inc. BEFORE USE 1. Carefully unpack your Air Purifier. Select a firm level place where there are no obstructions to the air inlet or filtered air outlet. 2. If the filter is covered by a bag when shipped, remove plastic bag before use and place filter into unit. 3. Select current month on the filter reminder dial. This will serve as reference for when filter replacement is needed. 4. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL. OPERATING INSTRUCTIONS 1. Plug into a 120V AC electrical outlet. 2. Select the desired operating speed from HIGH (III), MEDIUM (II) or LOW (I) by turning the knob to the desired setting. 3. To release negative ions into the filtered air, turn the ionizer knob to ON ( ) and the light will illuminate. For optimum air filtration, it is recommended to operate the air purifier continuously. Its rugged motor has been designed to provide many years of use. CLEANING/MAINTENANCEINSTRUCTIONS 1. Turn the air purifier off and unplug it before cleaning. 2. The outside of the air purifier can be cleaned with asoft, clean dampened cloth. 3. The front air inlet grill can be removed and washed in warm soapy water (not dishwasher safe). Dry beforereplacing in the unit. 4. The filtered air outlet can be cleaned of dust with a small, soft brush. 5. If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down. WARNING: Do not allow moisture to come in contact with the main housing of the air purifier. FILTER REPLACEMENT INSTRUCTIONS Note: Every few weeks, check the condition of the HEPA-type fitler. • Filter life will vary, depending on air quality and usage. • Under normal conditions of continuous use, the HEPA-type will operate efficiently for 3-6 months. • Use Filter Reminder Dial to keep track on how long a filter has been in use. 1. Turn off and unplug the air purifier. 2. Remove the air inlet grill. Remove and examine the foam pre-filter. If it has collected a noticeable amount of dust or lint, remove it from the inlet of the grill and wash it in warm soapy water. Rinse and drip dry the pre-filter thoroughly before replacing it into the inlet of the grill. 3. With the front grill removed, check the condition of the HEPA-type filter. Your air purifier has a convenient filter condition sticker that serves as a color-coded reference point to help in deciding on when to change the filter. If the filter is dirty, remove the used HEPA-type cartridge and properly dispose of it. DO NOT try to wash and re-use the HEPA-type filter. 4. Install the new HAPF30 filter into the unit. This model utilizes a hang tab and filter clips to insure that the filter is properly in place. Before replacing the filter, make sure that the hang tab is securely in place. The clip can only be attached to the tabs on the filter one way. The filter clip should easily slide onto the filter hang tab with only a small amount of pressure. DO NOT use force while attaching the clip to the filter. 5. Align the clip on the top of HEPA-type filter with rails on the inside of the purifier unit. Gently slide the filter onto the rail. (Figure 2) Figure 2 6. Replace air inlet grill. 7. Re-set the filter reminder dial by selecting the current month. Figure 1 G E B D F C A H A. AIR INLET GRILL B. WASHABLE FOAM PRE-FILTER C. HEPA-TYPE/CARBON FILTER D. IONIZER CONTROL E. IONIZER LIGHT F. FILTER REMINDER DIAL G. SPEED CONTROL H. FILTERED AIR OUTLET GRILL Filters can be purchased at a retailer near you...

Эта инструкция также подходит к моделям:
Воздухоочистители - HAP2400 (542.68 kb)
Воздухоочистители - HAP2400B-U (542.68 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории