Фрагмент инструкции


The treatment is a safe, silent, and proven way to make your home or office a healthier place to live and work. SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the UV-Aire Air Purifying System with the UV chamber open. WARNING: DO NOT mount this unit outdoors. • This product is designed for indoor installation only. AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE. This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION. This device MUST be installed by a qualified agency in accordance with the manufacturer's installation instructions. The definition of a qualified agency is: any individual, firm, corporation or company which either in person or through a representative is engaged in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the precautions required, and has complied with all the requirements of the authority having jurisdiction. Please retain these instructions after installation. Installed By: Phone: Installation Date: INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention of any disease or condition. GENERAL INFORMATION Model Volts Amps Hz Watts Lamp Intensity at 1 meter Recommended Max. Sq. Feet Weight Width (Inches) Height (Inches) Depth (Inches) UV-1500C 120 1.3 60 130 37.W/cm2 1500 15.5 lbs 18 23-3.4 6-5.16 WARNING: This product is designed for indoor installation only. The UV-1500C is designed as a multipurpose room air purification system. The unit can be placed in a room sitting on the floor, it can be mounted on the wall to maximize floor space, or it can be mounted into a suspension (drop) ceiling. FEATURES 1. The UV-1500C is equipped with a speed control to allow the user to adjust the airflow through the unit from 35 cfm to 100 cfm. 2. The UV-1500C has a safety shut off switch that disconnects power to the fan and the lamp if the front access door is opened. 3. The UV-1500C is equipped with a circuit board to monitor the operation of the UV lamp; it indicates the operation of the lamp through an LED indicator light mounted on the front access door. The circuit board indicates good operation of the lamp by a continuous “GREEN” color on the LED light. After 8320 hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “YELLOW” color on the LED light and the internal alarm will beep every 15 minutes. After 9000 hrs of lamp operation, the circuit board indicates the elapsed time of lamp operation by a continuous “RED” color on the LED light and the internal alarm will beep every 5 minutes. The board also checks if the UV lamp is burned out. The circuit board will indicate this by a continuous “RED” color on the LED and the internal alarm will beep every 5 minutes. UV-1500C CHECK OUT PROCEDURE 1. Plug the power cord into a standard 120-volt wall receptacle. 2. Turn the speed control knob clockwise to turn the unit on. After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation. 3. Once you have determined that the unit is functioning properly, turn unit off and unplug. 4. Continue to next section for mounting options. WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire® Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 2 FOR AREA OR ROOM OPERATION 1. Place the UV-1500C in the desired area; plug the power cord into a standard 120-volt wall receptacle. 2. Turn the speed control knob clockwise to turn on the unit and to adjust the motor/fan speed to the desired airflow. (See Figure 1) 3. After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation. Figure 1 WALL MOUNTING OPTION (The UV-1500C is supplied with four mounting brackets to allow the unit to be mounted onto a wall). 1. To install the mounting brackets, remove the eight mounting screws from the back of the UV-1500C. (See Figure 2) 2. Install the four mounting brackets onto the back of the housing securing them with the mounting screws you just removed. (See Figure 3) 3. Determine the desired location on the wall (a 120-volt wall receptacle should be within 5 feet of the unit) and mark the mounting screw locations based on the dimensions given in figure 4A...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории