Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Nilfisk-ALTO, модель C-90A

Производитель: Nilfisk-ALTO
Размер: 511.36 kb
Название файла: 061e92b7-0ba9-4fde-a6af-93190a12ccb6.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


In just minutes, you will notice improvements in your indoor air quality as your Friedrich air cleaner begins the job of removing the billions of irritating microscopic particles from your home or office. The activated carbon post-filter also helps eliminate many objectionable indoor odors. • Carry unit by handle indentations on side panels or carry from base, as the top removes for filter maintenance and will not support the unit. • Remove the plastic cover from the activated carbon filter, and place the filter with label facing out. • Make sure the electronic cell is properly placed in the cabinet - airflow arrow on the end plate should be pointing toward the fan. • Make sure that the top cover is securely in place. • This unit is equipped with a three-prong (grounded) plug for your protection against shock hazards and should be plugged directly into a properly grounded three-prong receptacle. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG. • Electronic air cleaners should NOT be placed in any area where potentially dangerous gasses or vapors exist, nor should they be used in wet environments. Pre-Filter Ionizing Section of Electronic Cell Plates 3-Speed Fan Carbon Filter Collector 920-010-05 (11-04) Operating Your Friedrich Electronic Air Cleaner W a l l Cleaning CONTROLS All controls for the Friedrich electronic air cleaner are located on the top of the unit and are accessible through an opening in the top cover. The controls are: OFF, HI, MED and LOW. An indicator lamp lights when the cleaner is on and operating normally. Generally, HIGH fan speed is used in extreme conditions for rapid cleaning; such as during or after a party where there were many smokers; or for larger areas to circulate the clean air in all areas of the room. MEDIUM and LOW settings are usually adequate to maintain a clean air environment. At initial start-up, the indicator lamp may flicker on and off and is not cause for alarm. Should the lamp completely fail to come on, review the "BEFORE OPERATING" and "TROUBLESHOOTING" sections. During initial use, “snapping” sounds may be heard. This is normal, and the unit may continue to make these noises during the first few days of operation. After this initial break in period, only an occasional "snap" will be heard, indicating the unit is cleaning your air. NOTE: As the air cleaner’s electronic cell becomes dirty, it will "snap" more frequently. When this occurs, you should wash the cell. The best location for the air cleaner is a place closest to the source of tobacco smoke, dust or other indoor contaminants. Position the unit so that the airflow around the intake and discharge grilles is not blocked. For best results, do not place the intake grille (rear) closer than eight (8) inches from a wall. Provide a clear, unobstructed path for the discharge air. The farther the discharge air travels, the greater the effectiveness of the air cleaner. For greater comfort, position the air cleaner so that the discharge air does not cause uncomfortable drafts. To use a room air cleaner most effectively in rooms that share an open doorway or archway, position the unit near the common opening and direct the airflow into the adjacent room to promote good air circulation. ECONOMICAL CLEAN AIR The Friedrich electronic air cleaner costs no more to operate than a standard household light bulb. The benefits from clean air far outweigh the low operating costs of continuous cleaning. Remember, the more you operate your electronic air cleaner, the cleaner your air will be. IMPORTANT PRECAUTIONS The collector plates of the electronic cell and the pre-filter can become extremely dirty. With an excessive amount of contamination buildup on the collector plates and the pre-fi lter, the electronic air cleaner’s efficiency decreases. Also, as dirt builds up on the ionizing wires, the charging process becomes less effi cient. To prevent this loss of efficiency, the electronic cell and pre-filter must be cleaned regularly. How often will depend on actual usage. Cleaning will be more frequent if the air cleaner is operated continuously or under severe conditions. Turn off and unplug air cleaner before opening top cover to remove electronic cell and prefilter for cleaning. Always be careful when handling the electronic cell. Sharp edges and wires are capable of inflicting wounds. Care should also be taken when cleaning because of extremely hot water and potentially harmful effects of detergents on your skin. 920-010-05 (11-04) Cleaning (Continued) CLEANING THE PRE-FILTER Remove the pre-filter and shake out or brush off the accumulated dust and lint. If this is not adequate, a vacuum may be used or the pre-filter can be cleaned with an all-purpose cleaning agent to remove tobacco smoke and cooking grease stains. A thorough rinsing is required after each cleaning. After cleaning, allow to dry and reinsert. CLEANING THE CARBON FILTER Occasionally, the carbon filter will need cleaning. Use...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории