Производитель: Powermatic
Размер: 1.1 mb
Название файла: 1791330_man.pdf
|
Фрагмент инструкции
Screw each eye bolt into the cabinet; turn it to desired position then tighten the hex nut against the cabinet with a 10mm wrench. Acaution The unit must be anchored to structure which will support a 100 pounds. Never mount to a building minimum of surfaces such as dry wall, false ceiling grids, etc. If mounting to ceiling, make sure chain and ceiling hooks are properly rated for hanging this unit. Clearance should be at least 7 feet from bottom of unit to the floor. This unit will work best if located away from corners and heating/cooling vents. Controls and Features Refer to Figure 2. The Air Filtration Unit can be operated by either the remote transmitter or the control panel on the cabinet. The remote transmitter uses radio frequency, and thus is not limited by line-of-sight operation. Fuse The fuse switch will pop out in case of overload. Wait 3 to 5 minutes and push the fuse switch back in. Speed The unit will always start on low speed. On the remote, press the up or down button to change speed. Or, on the control panel, press and release the Speed button. Timer Press the timer button on the remote (the timer indicator will start flashing). Then press the up or down button to scroll to the desired time (from 1 to 9 hours). Press the timer button again - the indicator will stop flashing. The unit will operate for the programmed time, at the end of which it will automatically shut off. Note: If the timer function is not used, the filtration unit will continue to operate until the off button is pressed. Change Filter The “Change Filter” indicator will light up after 200 hours of operation to remind the operator to inspect and to clean/replace filters if needed. To turn off the indicator light, press the Reset switch using a thin object, such as a ball point pen or paper clip. 8 Figure 1 Figure 2 Operation NOTE: The Air Filtration Unit is designed to remove airborne non-metallic dust particles; it is not designed to take the place of a dust collection system. Larger particles are trapped by the outer filter. Smaller particles are stopped by the fine mesh pockets of the inner filter. The air is then exhausted through the diffusion filter, which has a fibrous composition to help diffuse the air. Changing Filters Refer to Figure 1. Awarning Turn off, disconnect (unplug) the Air Filtration Unit from the power source before servicing or changing filters. There are two filters that need to be cleaned and/or replaced periodically, depending upon the amount of use and the environment of your shop. Using clogged filters will diminish the overall efficiency of the unit. The outer filter is disposable, but its life can be extended by occasional use of a shop vac or compressed air to clean off the dust. For maximum efficiency, however, a dirty outer filter should be discarded and replaced with a new one. (An optional, washable outer filter is available - stock no. 1791085.) The inner filter can be blown out with air or washed out. (Allow to dry before re-installing.) The diffusion filter will not need replacing. It should be inspected occasionally, and if needed, cleaned by light vacuuming or compressed air. (An optional charcoal diffusion filter - stock no. 1791084 - may be purchased, and is used to reduce non-volatile fumes or odors.) 9 Transmitter Replacement The remote transmitter provided with your Air Filtration Unit is pre-programmed and ready to operate once the battery is installed. However, should you ever need to replace the remote transmitter, the new transmitter will need to be programmed for your Air Filtration Unit. This is easily done, as follows (Figures 4 and 5): 1. Start the Air Filtration Unit. 2. On the Air Filtration Unit’s control panel, press and hold the Speed and Timer buttons simultaneously for 4 seconds, until you hear a “beep”. 3. Turn on the remote transmitter. 4. You should now be able to operate the machine using the remote transmitter. Figure 3 Hole Dimensions Figure 4 Figure 5 10 Replacement Parts Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800-274-6848, Monday through Friday (see our website for business hours, Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. 11 Parts Breakdown for PM1200 Air Filtration System 12 20 Parts List for PM1200 Air Filtration System Index No. Part No. Description Size Qty 1.............. .1791083.............. ......Outer Filter for PM1200................................ ......... 1 2.............. .1791082.............. ......Inner Filter for PM1200................................. ......... 1 3.............. . PM1200-03......... ......Retaining Plate............................................. ......... 1 4.............. . PM1200-04......... ......Rivet............................................................. ......NSS 4-4.....