Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации GE, модель GNULQ

Производитель: GE
Размер: 650.54 kb
Название файла: 0729b33e-73b9-4834-91fd-ec487cbf39f8.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


You must follow these guidelines as you install the Kitchen and Bath Main Faucet Filtration System. Using a qualified installer is recommended. • Be sure the water supply conforms with the Performance Data. If the water supply conditions are unknown, contact your municipal water company. WARNING — Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. • It is highly recommended that a water shut-off valve be placed directly upstream of your Kitchen and Bath Main Faucet Filtration System. PROPER INSTALLATION This Kitchen and Bath Main Faucet Filtration System must be properly installed and located in accordance with the Installation Instructions before it is used. • Check with your local public works department for plumbing codes. You must follow their guides as you install the Kitchen and Bath Main Faucet Filtration System. • Use the Kitchen and Bath Main Faucet Filtration Systemon a potable, safe-to-drink, home COLD water supply only. The filter cartridge will not purify water or make unsafe water safe to drink. DO NOT use on HOT water (100°F max). • Protect the Kitchen and Bath Main Faucet Filtration Systemand piping fromfreezing. Water freezing in the system will damage it. • Your Kitchen and Bath Main Faucet Filtration Systemwill withstand up to 100 psi water pressure. If your house water supply pressure is higher than 100 psi during the day (it may reach higher levels at night), install a pressure reducing valve before the system is installed. • Do not install on HOT WATER. The temperature of the water supply to the Kitchen and Bath Main Faucet Filtration System must be between the minimum of 40°F and the maximum of 100°F. See the Performance Data section. • Do not install the Kitchen and Bath Main Faucet Filtration System using copper solder fittings. The heat from the soldering process will damage the unit. WARNING — Discard all unused parts and packaging material after installation. Small parts remaining after installation could be a choke hazard. • Do not install filter in an outside location or anywhere it will be exposed to sunlight. System is Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine, Taste and Odor and Particulate Class I and Standard 53 for the reduction of Turbidity. PARTS INCLUDED • Filter Cartridge • Filter Head/Bracket • 6 Feet of 3/8. Tubing • 3/8. x 1/2. Faucet Adapter • 3/8. Compression Hex Nut • 3/8. Ferrule • 3/8. Tube Insert • Mounting Screws • 1/2. Compression to 3/8. Adapter • 7/16. Compression to 3/8. Adapter Optional accessories are available (Visa, MasterCard or Discover cards accepted) by visiting our Website at ge.com or from Parts and Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada). TOOLS YOU WILL NEED Adjustable Wrench Utility Knife Phillips-Head Screwdriver Drill with 1/8. Drill Bit 238C3375P001 49-50225-1 07-07 JR 1 Printed in China Installation Instructions CARTRIDGE SPECIFICATIONS Performance Data – Filtration System GXULQ Using Filter GXULQR This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53. Actual performance may vary with local water conditions. Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Standard No. 42: Aesthetic Effects Parameter USEPA MCL Influent Challenge Concentration Influent Average Effluent % Reduction Reduction Requirement Average Maximum Average Minimum Chlorine taste and odor — 2.0 mg/L ± 10% 1.9 mg/L <0.05 mg/L 0.05 mg/L >97.4% 97.4% .50% Particulate, Class Iparticles 0.5 to <1um** — .10000 particles/mL 10333333 #/mL 20,500 #/mL 41,000 #/mL 99.8% 99.6% .85% Standard No. 53: Health Effects Parameter USEPA MCL Influent Challenge Concentration Influent Average Effluent % Reduction Reduction Requirement Average Maximum Average Minimum Turbidity 1 NTU*** 11 ± 1 NTU*** 11.00 NTU0.1 NTU 0.1 NTU 99.1% 99.1% 0.5 NTU *Tested using a flow rate of 2 gpm (7.6 l/min); pressure of 60 psig; Operating Specifications pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) Capacity: certified for up to 2000 gallons (7,571 l); up to six months **Measurement in particles/mL. Particles used were 0.5–1 microns. Pressure requirement: 35–100 psi (2.8–6.9 bar) ***NTU—Nephelometric Turbidity Units Temperature: 33°–100°F (0.6°–38°C) HOT COLD IN OUT Optional installation STEP-BY-STEP INSTALLATION INSTRUCTIONS Installation Overview NOTE: Be sure to allow a minimum space of 11/2.–2. under the system for removing the filter cartridge. If you have copper tubing with 3/8. compression fittings, you’ll need to follow Step 3 Option B (Optional Installation). HOT COLD IN OUT ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории