Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Kenmore, модель UltraSoft 100 625.388150, 150 625.388160

Производитель: Kenmore
Размер: 683.96 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


It will not remove other types of iron, acids, tastes and odors, etc. It will not purify polluted water or make it safe to drink. ▲ Protect the softener and piping from freezing. Damage from freezing voids the softener warranty. See page 3-3. CAUTIONS PLEASE READ AND COMPLY WITH THE FOLLOWING GUIDES TO PREVENT DAMAGE TO THE SOFTENER OR OTHER PROPERTY, PERSONAL INJURY, OR POSSIBLE FATAL SHOCK. ▲ THIS SOFTENER WORKS ON 24 VOLTS ONLY. BE SURE TO USE ONLY THE TRANSFORMER INCLUDED, AND PLUG IT INTO A HOUSEHOLD 120V OUTLET. IF TRANSFORMER IS REPLACED, USE ONLY THE AUTHORIZED SERVICE, CLASS II, 24 VOLT, 10 VA TRANSFORMER. ▲ Unplug the transformer right away if the power cable should become damaged or frayed. Make repairs before plugging back into the power outlet. ▲ Always unplug the softener from electrical power before removing outer valve covers. ▲ This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. _1^1_ Problems, Questions? Call 1-800-426-9345 Kenmore Water Line SECTION 1 WATER SOFTENER START UP B. CHECK LIST OF STEP-BY-STEP GUIDES TO INSTALL To be sure you have done all the steps to install the softener, read the following list. Refer to the Installation Manual, part no. 7231741, for step-by-step guides. Page numbers referred to are in the Installation Manual unless otherwise noted. S Is the house water flow going INTO the softener valve INLET? Trace piping to be sure. See pages 2-4 and 2-5. S Is the plumbing bypass valve (or 3 valves) set for SERVICE? Bypass valve(s) should always remain in soft water service position. Position in "bypass" only if needed for softener repairs. See FIG. 14, page 4-1 of this manual. S Is the valve drain hose connected the right way, and without sharp bends or kinks that could stop or reduce water flow? See page 3-5 in the installation manual. Page numbers referred to are in the Installation Manual unless otherwise noted. S Is the softener power cable connected to the transformer? Is the transformer plugged into an inside, always live 120V-60Hz electrical outlet? See pages 3-8 and 3- 9 in the installation manual, and the wiring schematic on page 5-1 of this manual. S Be sure to restart the water heater. See page 3-9. FIG. 1 3-valve plastic Bypass Valve(s) NOTE: Codes in the state of Massachusetts require installation by a licensed plumber. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts. 1 - 2 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line SECTION 1 WATER SOFTENER START UP C. PROGRAM THE TIMER FIG. 2 display UP button ON/OFF-HOLD button (Recharge Tonight-Now) DOWN button SELECT button When the transformer is plugged in, a model code, and a test number (example: S3.0) show in the face plate display for 4 seconds. Then, 12:00 AM and PRESENT TIME begin to flash. UltraSoft 100 UltraSoft 150 Notes: If SR - - shows in the display, press the UP 0 or DOWN ® button until SR22 or SR24 shows. Then, press the SELECT button to set, and change to the flashing PRESENT TIME display. To check the model code, unplug the transformer at the wall outlet and plug in again. if other than SR22 or SR24 shows, see page 5-3 to reset. SOUND "BEEPER": A "beeper" sounds while pressing buttons for timer set-up. One beep signals a change in the face plate display. Repeated beeps mean the timer will not accept a change from the button you have pressed, telling you to use another button. For example, while setting the hardness (step 2), the beeper sounds repeatedly when the display reaches 1 using the DOWN button, or the highest hardness setting using the UP button. SET PRESENT TIME OF DAY If the words PRESENT TIME do not show in the display, press the SELECT button (FIG. 2) until they do, or see the previous notes. ■ Press the UP / DOWN buttons to set the present time. Press UP to move the display ahead; press DOWN to move the time backward. If the present time is between noon and midnight, be sure PM shows. If the present time is between midnight and noon, be sure AM shows. 458F PRESENT TIME 1136' PRESENT TIME Each press of the UP /DOWN buttons changes the time by one minute. Holding the buttons in changes the time rapidly. 1 - 3 Problems, Questions? Call 1-800-426-9345 Kenmore Water Line SECTION 1 WATER SOFTENER START UP C. PROGRAM THE TIMER H SET WATER HARDNESS NUMBER ■ Press the SELECT button once to display 25 (flashing) and HARDNESS. The grains per gallon (gpg) hardness of your water supply is on your water analysis report. Be sure to enter water test results on page A, for future reference. If your water supply contains iron, compensate for it by adding to the water hardness number. For example, assume your water is 20 gpg hard and contains 2 ppm iron. Add 5 to the hardness number for each 1 ppm of iron. In this example, you would use 30 for your hardness number. 2 ppm iron x 5 =...

Эта инструкция также подходит к моделям:
Водоочистители - 100, 150 (683.96 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории