. . Control Supplement and Gas Control Parts for Natural or Propane gas with optional tankless heater application EGH Read all instructions before installing Installer Leave all instructions with boiler for future reference. Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee. Owner Installation and service should be performed by qualified service technician. Part No. 550-110-639/0703 EG, PEG, EGH GAS-FIRED BOILERS — SERIES 4 — BOILER MANUAL Contents Installation ............................................................................................. 3 Piping Connections................................................................................ 9 Install Boiler Controls..........................................................................12 Optional Heaters .................................................................................13 Gas Piping............................................................................................14 Wiring ...................................................................................................15 Final Adjustments................................................................................16 Check Out Procedure ..........................................................................18 Service ..................................................................................................19 Replacement Parts...............................................................................22 Data ......................................................................................................26 Ratings .................................................................................................27 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels, or to important information concerning the life of the product. Indicates presence of hazards that will cause severe personal injury, death or substantial property damage. Indicates presence of hazards that can cause severe personal injury, death or substantial property damage. Indicates presence of hazards that will or can cause minor personal injury or property damage. Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury or property damage. The boiler contains ceramic fiber and fiberglass materials. Use care when handling these materials per instructions on page 19 of this manual. Failure to comply could result in severe personal injury. Do not use petroleum-based cleaning or sealing compounds in boiler system. Severe damage to system components can result, causing substantial property damage. Read all instructions before installing. Failure to follow all instructions in proper order can cause severe personal injury, death or substantial property damage. When calling or writing about the boiler— Please have the boiler model number from the boiler rating label and the CP number from the boilerjacket.You may list the CP number in the space provided on the Installation and service certificate found on page 18. Important EG and EGH boilers for tankless or storage heater application are available only on special order as factory-installed optional equipment. Tankless heater cannot be added to standard block assembly. Block assembly must be ordered with heater openings. Standard boilers cannot be adapted for heater use. Part Number 550-110-639/0703 EG, PEG, EGH GAS-FIRED BOILERS — SERIES 4 — BOILER MANUAL Installation Codes Installations must comply with all local codes, laws, regulations and ordinances. Also National Fuel Gas Code ANSI Z223.1-latest edition. When required, installations must conform to Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1. Safe lighting and other performance criteria were met with the gas manifold and control assembly provided on boiler when boiler underwent tests specified in ANSI Z21.13-latest edition. Canadian installations must comply with CAN/CSA B149.1 or .2 Installation Codes. The equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction shall be consulted before installations are made. Combustion air and ventilation openings Combustion air and ventilation openings must comply with Section 5.3, Air for Combustion and Ventilation, of National Fuel Gas Code ANSI-Z223.1-latest edition, or applicable building codes. Canadian installations must comply with CAN/CSA B149.1 or .2 Installation Codes. Provide adequate combustion and ventilation air to: • Assure proper combustion • Reduce risk or severe personal injury or death from flue gas spillage and carbon monoxide emissions. Do not install an exhaust fan in the boiler...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории