Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Bryan s, модель DR250

Производитель: Bryan s
Размер: 264.55 kb
Название файла: 2178.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


CONSULT FACTORY FOR CERTIFIED DIMENSIONS. 5. ALL FLANGES ARE 150# UNLESS OTHERWISE NOTED, FLANGES TO STRADDLE CENTER LINE. PLAN VIEW FR°NT VIEW RIGHT SIDE VIEW REAR VIEW 1. PROBE TYPE AUX. L.W.C.O. 6. JACKET ACCESS PANELS 11. DRAIN/ BLOWDOWN - 1" NPT 16. HEIGHT OVER JACKET 2. FORCED DRAFT BURNER 7. PRESSURE GAUGE 12. BURNER CENTER LINE 17. HEIGHT OVER SUPPLY 3. RELIEF VALVE 8. CLNOUT./INSP. OPNG.-1 1/2"NPT 13. OIL PUMP LOCATION 18. MINIMUM SAFE WATER LEVEL 4. ASME NAMEPLATE 9. ELEC. ENCLOSURE - 14. LIFTING LUG 19. PRESSURE CONTROLS 5. LWCO/PUMP CONTROL - 157 10. CLNOUT./INSP. OPNG. - 2" NPT 15. FEED CONNECTION 2" NPT BOILER MODEL DR250 DR350 DR450 DR650 DR850 A-LENGTH OVER JACKET 33 3/4" (85.72) 33 3/4" (85.72) 33 3/4" (85.72) 45 1/16" (114.45) 45 1/16" (114.45) B-FLUE LOCATION 13 3/4" (34.92) 13 3/4" (34.92) 13 3/4" (34.92) 13 3/4" (34.92) 13 3/4" (34.92) C-FLUE DIAMETER 6" (15.24) 6" (15.24) 6" (15.24) 8" (20.32) 8" (20.32) D-LENGTH OVER BASE 62 1/8" (157.79) 62 1/8" (157.79) 62 1/8" (157.79) 73 1/2" (186.69) 73 1/2" (186.69) G-SUPPLY NOZZLE SIZE 3" (7.62) 3" (7.62) 3" (7.62) 4" (10.16) 4" (10.16) H-BURNER EXTENSION CONSULT FACTORY FOR BURNER EXTENSION ÈD BRYAN BOILERS 783 NORTH CHILI AVE PERU, INDIANA 46970 ORDER NO.: ORDER REV. NO.: FORM NO.: 2178 BRYAN BOILERS DR SERIES FORCED DRAFT STEAM BOILERS REVERSE CONSTRUCTION Form # >> 2178 Date >> 2/20/04 BOILER MODEL DR250 DR350 DR450 DR650 DR850 INPUT MBH 250 350 450 650 850 (KW) 73.2 102.5 131.8 190.4 249.0 OUTPUT MBH 200 280 360 520 680 (KW) 58.6 82.0 105.5 152.4 199.2 BOILER HORSEPOWER HP 6 8 10 15 20 (KW) 58.6 82.0 98.0 147.0 196.0 TUBE DIAMETER INCHES 1.00 1.00 1.00 1.00 1.00 (CM) 2.54 2.54 2.54 2.54 2.54 NUMBER OF TUBES 18 18 18 29 29 PRESSURE VESSEL VOLUME GAL 31 31 31 45 45 (L) 117.3 117.3 117.3 170.3 170.3 HEATING SURFACE SQ FT 66 66 66 103 103 (SQ M) 6.1 6.1 6.1 9.6 9.6 STEAM OUTPUT* LBS/HR 206 288 371 536 701 (KG/HR) 93.4 130.6 168.3 243.1 318.0 OPERATING WEIGHT LBS 1,408 1,408 1,408 2,025 2,025 (KG) 638.9 638.9 638.9 918.6 918.6 SHIPPING WEIGHT LBS 1,150 1,150 1,150 1,650 1,650 (KG) 521.6 521.6 521.6 748.4 748.4 RELIEF VALVE TYPICAL - 15 PSIG (103.4 KPA) QUANTITY A v a N i o l t a b l e (1) 13-213-08 (1) 13-213-08 (1) 13-213-08 (1) 13-213-08 SIZE INCHES 1-1/4 x 1-1/4 1-1/4 x 1-1/4 1-1/4 x 1-1/4 1-1/4 x 1-1/4 (CM) 3.175 x 3.175 3.175 x 3.175 3.175 x 3.175 3.175 x 3.175 CAPACITY-TOTAL MBH 1,200 1,200 1,200 1,200 (KW) 351.6 351.6 351.6 351.6 RELIEF VALVE TYPICAL - 150 PSIG (1034.0 KPA) QUANTITY (1) 6021DC01 (1) 6021DC01 (1) 6021DC01 (1) 6021DC01 (1) 6021DC01 SIZE INCHES 1/2 x 3/4 1/2 x 3/4 1/2 x 3/4 1/2 x 3/4 1/2 x 3/4 (CM) 1.27x1.905 1.27x1.905 1.27x1.905 1.27x1.905 1.27x1.905 CAPACITY-TOTAL MBH 925 925 925 925 925 (KW) 271.0 271.0 271.0 271.0 271.0 * Output based on nominal 80% of input. Actual combustion efficiencies will be higher and fuel dependent....

Эта инструкция также подходит к моделям:
Водонагреватели - DR350 (264.55 kb)
Водонагреватели - DR450 (264.55 kb)
Водонагреватели - DR650 (264.55 kb)
Водонагреватели - DR850 (264.55 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории