|
Фрагмент инструкции
Three output models cover this range and to ensure easy flue installation, each is available with or without a fan to overcome the flue pressure loss of the GT Condenser if necessary. A 6 bar working pressure capability ensures system application is straight forward. gas atmospheric Concord CXA/H S/H 40 - 120kW • Ultra reliable gas atmospheric boilers • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Auto ignition • Remote indication kit options • CXA/H natural gas or propane CXA P/H (40-100kW) • CXA/H is On/Off and CXS/H is High/Low operation Model 40/H 50/H 60/H 70/H 80/H 90/H 100/H 110/H 120/H Sections 3 4 4 5 5 6 6 7 7 Output (kW) 40 50 60 70 80 90 100 110 120 Height 1000 Width 600 Depth 750 882 882 1042 1042 1212 1212 1385 1385 Flow/Return Connections (BSP) RC2 Gas Inlet (BSP) RC3/4 RC3/4 RC3/4 RC3/4 RC3/4 RC1 RC1 RC1 RC1 Flue Size (mm) 150 150 175 175 200 200 200 250 250 Maximum Working Pressure (bar) 6 Water Content (L) 22 30 30 37 37 45 45 53 53 Approx Dry Weight (kg) 210 265 265 330 330 395 395 490 490 Front (mm) 750 Back (mm) 0 0 0 150 150 300 300 300 300 Sides (mm) 50 50 50 50 50 100 100 100 100 General Data Concord CXA/H S/H (40 - 120) Boiler Clearances Option Kits Boiler CXA/H CXS/H Volt free contacts, boiler run, overheat & lockout . . Down draft thermostat kit . . Header kits (available from merchants) . . Propane models . 10 Concord Modular 80 - 720kW • Suitable for Concord CXA/H and CXS/H models • Multiple installation outputs from 80-720kW • All servicing and maintenance from the front of boilers • Large clean-out cover for full access to flueways • Standard boiler width: 600mm • Factory assembled and tested units • Sequencer control kit available • Remote indication kit options Model40/H50/H60/H70/H80/H90/H100/H110/H120/HNo. Boilers 2x 80kW 100kW 120kW 140kW 160kW 180kW 200kW 220kW 240kW 3x 120kW 150kW 180kW 210kW 240kW 270kW 300kW 330kW 360kW 4x 160kW 200kW 240kW 280kW 320kW 360kW 400kW 440kW 480kW 5x 200kW 250kW 300kW 350kW 400kW 450kW 500kW 550kW 600kW 6x 240kW 300kW 360kW 420kW 480kW 540kW 600kW 660kW 720kW General Data Concord Modular (80 - 720) Option Kits Boiler Modular Sequencer control kit . Outside sensor kit Mandatory Sequencer control kit 11 gas atmospheric Concord CXSi/H 110 - 180kW • Ultra reliable gas atmospheric boilers • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Auto ignition • Remote indication kit options • High/Low operation Model 110/H 120/H 140/H 160/H 180/H Sections 7 7 8 9 10 Output (kW) 110 120 140 160 180 Height 1000 Width 1107 1107 1230 1353 1476 Depth 1036 1036 1036 1086 1140 Flow/Return Connections (mm) Flow: DN65 Flange. Return RC2 Gas Inlet (BSP) RC11/2 Flue Size (mm) 250 250 250 250 300 Maximum Working Pressure (bar) 6 Water Content (L) 53 53 60 68 76 Approx Dry Weight (kg) 520 520 587 654 721 Front (mm) 700 Back (mm) 200 Side (mm) 100 (not including clearance for side fitted flow header) General Data Concord CXSi/H (110 - 180) Boiler Clearances Option Kits Boiler CXSi/H Volt free contacts, alarm & boiler run conditions . 12 Concord ES/H 140 - 380kW • High/Low adjustable operation on all models • High, full and part load efficiencies meets Building Regulations 2006 (Part L2) • Assembled or unassembled heat exchanger availability • Robust cast iron heat exchanger • Easy to install and service • Low return temperature capability General Data Concord ES/H (140 - 380) Model 140/H 160/H 180/H 200/H 220/H 260/H 300/H 340/H 380/H Sections 8 9 10 11 12 14 16 18 20 Output (kW) 140 160 180 200 220 260 300 340 380 Height 1406 1406 1406 1406 1406 1406 1406 1406 1406 Width 970 1058 1146 1234 1322 1498 1674 1850 2026 Depth 1362 1362 1362 1362 1362 1412 1412 1412 1462 Flow/Return Connections (BSP) R2 Gas Inlet (BSP) RP1 RP1 RP1 RP1 RP1 RP11/4 RP11/4 RP11/4 RP11/2 Flue Size (mm) 250 250 300 300 300 350 350 350 400 Maximum Working Pressure (bar) 6 Water Content (L) 61 68 76 84 91 106 122 137 154 Approx Dry Weight (kg) 667 730 807 880 934 1096 1227 1364 1476 Front (mm) 1000 Back (measured from rear edge of jacket) (mm) 500 At sides Water connection side (RH or LH) (mm) 400 At sides Non connection side (RH or LH) (mm) 200 Boiler Clearances Option Kits Boiler ES/H Hours run meter (1 or 2 hours) . Flue gas thermometer . 13 high efficiency Super Series 4 50 - 600kW • Vertical and horizontal models • High efficiency 85% (gross) • Low NOx emissions (class 5) • 50kW Modules • Sequence controlled • Compact size • Complete package gas/water headers Model 50/V 100/V 150/V 150/VA 200/V 250/V 250/H 300/V 300/H 350/V 400/V 450/V 450/H 500...
Эта инструкция также подходит к моделям:Водонагреватели - F270 (1.05 mb)
Водонагреватели - 30 (1.05 mb)
Водонагреватели - F180 (1.05 mb)
Водонагреватели - F220 (1.05 mb)