|
Фрагмент инструкции
CK 62 Thermally Activated Post Purge. Installation of Power Venter The .Installation Code for Oil-Burning Equipment (CSA B139-04). or .Standard for the Installation of Oil- CK SERIES CONTROL KIT DRAFT REGULATOR OIL FIRED WATER HEATER SWG II 4HD POWER VENTER Figure 6 POWER VENTING SEE MANUFACTURER.S INSTRUCTIONS Burning Equipment (NFPA 31)., local codes and the manufactures instructions should be adhered to in all installations of the water heaters and power venters. A draft regulator must be used in conjunction with the installation of the power venter (see .Draft Regulator.). Consult the applicable codes to calculate total equivalent vent pipe length, the straight runs of pipe and the equivalent length of pipe for each fitting. Burner Installatio. General The installation of these units shall be in accordance with the .Installation Code for Oil-Burning Equipment (CSA B139-04). or .Standard for the Installation of Oil- WARNING This installation must be performed by a qualified Oil-Burner Technician in accordance with these instructions and diagrams. The installation and maintenance of the water heater must follow all of the instructions in preceding sections of this manual. Improper installation can cause injury or property damage. Heater failure that is a result of the heating system is not covered by warranty. . 8. Burning Equipment (NFPA 31). (as applicable), local codes and the manufacturer.s instructions. The burner should be installed only by a qualified Oil-Burner Technician. Oil Supply Connection. All aspects of oil tank location and installation, tank size, oil piping supply and burners, including any fittings, valves, filters or any fuel handling components must comply with: • .Installation Code for Oil Burning Equipment (CAN/CSA-B139)., (Canada). • .Standard for the Installation of Oil-Burning Equipment. (NFPA 31)., (USA). • Local codes and regulations. . Information provided with burner and fuel pump. Install the oil supply tank with fill and vent lines of adequate capacity as shown in Figure 4. When an appliance using a float valve between the supply tank and the burner is connected to a supply tank over 9 Canadian gallons capacity, a valve operated by a fusible link, shall be installed in the fuel line adjacent to, and upstream from, the float valve. If any part of fuel oil tank is above level of burner, an anti-siphon device must be used to prevent flow of oil in case of oil line break. Support the oil lines as required by applicable codes. Make tank connections with swing joints or copper tubing to prevent breaking in case the tank settles. Make the swing joints so they will tighten as tank settles. Non-hardening pipe joint compounds should be used on all threads. Do not use Teflon® tape as an oil pipe sealant. It can cause valves to fail creating hazards. Do not use compression fittings. Underground pipe must be run in a casing to prevent oil leaking into ground or under floor. Check local codes for more information. Water Supply Connection. Pipes and fittings should be installed in as shown in the installation drawing (Figures 7 & 8). Install a shut-off valve in the cold water supply line in close proximity to the cold inlet of the water heater. This valve is for use only when servicing the heater and must be kept open during the heater.s operation. The water connection fittings (nipples) may contain a non-metallic lining to minimize corrosion and some models include non-metallic heat traps. These appear like pink or blue coloured plugs in the fitting. Do not attempt to pry these plugs loose or damage them. DO NOT APPLY HEAT DIRECTLY TO THE WATER HEATER NIPPLES. If copper piping is used, solder a piece of tubing to a threaded adaptor before screwing the adaptor to the nipples. Use only solder approved for use with potable water systems. Use a good grade of pipe joint compound, certified for use with potable water, on the threaded fittings. Be sure all fittings are drawn up tight. NOTE: Rear and Combination flue heaters are equipped with a combination cold water inlet/drain valve. Temperature and Pressure (T&P) Relief Valve To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective equipment as required by local codes. It should be no less than a combination Temperature and Pressure (T&P) Relief Valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements of the latest edition of ANSI Z21.22: Requirements for Relief Valves and Automatic Gas Shut-off Devices for Hot Water Supply Systems. This valve must be marked with a maximum set pressure not to exceed the marked MAXIMUM working pressure of the water heater (150 psi (1034 kPa). The function of the temperature and pressure relief valve is to discharge water in quantities, should circumstances demand. To prevent property damage, bodily injury or hazard to life the re...
Эта инструкция также подходит к моделям:Водонагреватели - JW527 JWF307V (338.9 kb)
Водонагреватели - JW317 (338.9 kb)
Водонагреватели - JWF307 (338.9 kb)
Водонагреватели - JW317 (338.9 kb)