Water too hot and/ 2. Temperature set too high 2. Reduce temperature setpoint or ER2 message on 3. Temperature sensor not fully inserted 3. Re-insert thermistor wire or temperature sensor. Smart Control™ 4. Stuck zone valve 5. Flow check valve stuck open 4. Repair or replace 5. Clean, repair or replace 1. Air in boiler loop 1. Purge boiler loop. Check air elimination equipment. Noise from 2. Faulty circulator pump 2. Repair or replace pump BoilerMate® 3. Thermal expansion 3. Ensure the proper Therm-X-Trol® or equivalent thermal expansion tank is installed and adjusted properly 4. Normal noise during initial fill 4. When first pressurized, a creaking or hissing sound is normal. After pressurizing, the noise should stop. Always check for leaks. 1. No thermal expansion tank 1. Install the proper Therm-X-Trol® or equivalent thermal expansion tank Relief valve 2. Thermal expansion tank set improperly 3. City pressure too high 2. Ensure precharge air pressure matches static water pressure 3. Install a Pressure Reducing Valve (PRV) if city pressure is over 80psidripping or opening 4. System over temperature 4. Determine cause of over temperature condition and correct problem 5. Faulty relief valve 5. Replace relief valve ER1 message on Smart Control™ 1. Temperature sensor unplugged 2. Temperature sensor cut or faulty 3. Water in therm-well 1. Sensor is unplugged from factory. Plug into Smart Control™ receptacle 2. Replace sensor wire (thermistor) 3. Replace therm-well Discolored water at faucet 1. Poor water quality 2. Sediment or suspended particles 1. Have water tested for contaminants. Typical problems are: Blue/green color = copper discoloration due to low pH Black staining/sulfur odor = hydrogen sulfide White deposits = hard water Red staining = high iron levels 2. Install sediment filter, purge unit more often to avoid future problems 1. Improper or loose wiring 1. Check connections against wiring diagrams in this manual Boiler will not 2. Boiler high limit has been reached 2. Boiler will periodically cycle on and off during operation operate when 3. Fuse blown in Smart Control™ 3. Remove 4 screws inside the Smart Control™ wiring box. Replace glass fuse(s) calling for hot water 4. Post Purge (POS) set too high with those of the same rating 4. Post Purge shuts the boiler off prior to reaching domestic setpoint. If set too high, the boiler may not have enough energy to raise the water temperature to setpoint. Reduce POS or set to 0 if the problem persists 5. Problem with boiler system 5. Have boiler diagnosed for proper operation Circulator or zone valve will not 1. Improper or loose wiring 2. Pre Purge (PRE) set too high 1. Check connections against wiring diagrams in this manual 2. PRE setting delays circulator startup. This is not normally needed in residential operate when applications. Reduce PRE or set to 0 if problem persists calling for hot 3. Fuse blown in Smart Control™ 3. Remove 4 screws inside the Smart Control™ wiring box. Replace glass fuse(s) water 4. Faulty circulator pump with those of the amp same rating 4. Repair or replace pump -27 14. REPLACEMENT PARTS WH-7, 41 and 9 Series TD-7 Series TD-7 RTR TD-80 Series WHS 60 & 80 Residential WHS 120 Residential WHS 60 & 80 Commercial WHS 120 Commercial Single Wall Heat Exchanger w/Gasket and Nuts 2700-5000 2700-5005 2700-5007 2700-5008 2775-82 2775-81 2700-5001 2700-5001 Double Wall Heat Exchanger w/Gasket & Nuts 2700-5002 2700-5006 N/A N/A 2775-83 2775-83 2775-84 2775-84 Commercial Heat Exchanger w/Gasket & Nuts 2700-5001 N/A N/A N/A N/A N/A See Above See Above Top Outlet Tee w/O-Ring 2700-635 N/A N/A N/A N/A N/A N/A N/A Flange Gasket: Bottom & Top 2704-403 2704-403 2704-403 2704-403 2704-403 2704-403 2704-403 2704-403 Thermo-Well Assembly 2700-924 2700-924(exc DW) 2700-924 2700-1167 2700-924 2700-924 2700-924 2700-924 Top Outlet O-Ring or Bottom Drain O-Ring 2500-178 2500-178 2500-178 2500-178 N/A N/A N/A N/A Smart Control™ 2704A233 2704A233 2704A233 2704A233 2704A233 2704A233 N/A N/A Sensor (thermistor) wire 2704-259 2704-259 2704-259 2704-259 2704-259 2704-259 N/A N/A Dial Aquastat (residential) 2704-093 2704-093 2704-093 2704-093 2704-093 2704-093 N/A N/A Dial Aquastat (commercial) N/A N/A N/A N/A 2775-454 2775-454 2775-454 2775-454 Conversion Kit: Dial Aquastat to Smart Control™ 2704-227 2704-227 N/A 2704-227 2775-389 2775-389 2775-389 2775-389 Conversion Kit: Smart Control™ to Dial Aquastat 2704-392 2704-392 N/A 2704-392 2775-455 2775-455 2775-455 plus 2775-454 2775-455 plus 2775-454 Circulator Pump 245-58 245-58 245-62 245-58 245-58 245-58 N/A N/A Water Sensor 2704-495 245-58 245-62 245-58 245-58 245-58 N/A N/A To obtain replacement parts, contact the installer or place of purchase. Technical support is available by calling AMTROL at (401) 535-1216. -28 15. CLEANING THE BOILERMATE® HEAT EXCHANGER COIL A diminished temperature difference between 7. Set the temperature control to its highest setting and the boiler water entering and leaving the...
Эта инструкция также подходит к моделям:Водонагреватели - BoilerMate RTR (4.6 mb)
Водонагреватели - BoilerMate Top Down (4.6 mb)
Водонагреватели - WH-7 Classic Series (4.6 mb)