Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Crown, модель BB100H

Производитель: Crown
Размер: 920.29 kb
Название файла: Bimini_Buddy_Literature.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


In addition, some models include provisions for domestic hot water production. The BB100I and BB100C models utilize the circulator that comes with the Bimini boiler so a separate DHW circulator isn't required. They also include a three way zone valve for domestic hot water priority that is wired directly to the Bimini without the use of any additional controls. All Bimini Buddies have an attractive jacket and convenient connections for the boiler system, air vent and expansion tank. The Bimini Buddy has reversible piping so that it can be piped either right or left of the boiler (factory piping is for installation on right side of boiler.) Three Bimini Buddy Models BB100H - For heat only applications. BB100I - For connection of a Bimini boiler to a heating system and an indirect water heater like the Mega-Stor. BB100C - Combi unit with a plate heat exchanger and flow switch for domestic hot water production in tight places. BIMINI BUDDY TECHNICAL INFORMATION *Expansion tank not included. SPECIFICATIONS MAX. MAX. 3-WAY VALVE FLOW FLOW SWITCH DIMENSIONS MAX MODEL OPERATING OPERATING MOTOR SWITCH CONTACT WEIGHT EXPANSION PRESSURE TEMP. RATING SET-POINT RATINGS WIDTH HEIGHT DEPTH TANK DIA. BB100H 12" 19-3/4" 12-1/2" 24 LBS 11" BB100I 50 PSI 200°F 120VAC, 50/60 0.50 GPM 20VA PILOT 12" 19-3/4" 12-1/2" 27 LBS 11" BB100C HZ, 6.5 W DUTY AT 120VAC 12" 19-3/4" 12-1/2" 30 LBS 11" Domestic Hot Water Output for Bimini Buddy Models BB100C Bimini Boiler Continuous Draw (GPM) 77oF Rise 90oF Rise BWC070 1.53 1.32 BWC090 2.09 1.80 BWC120 2.70 1.84 BWC151 2.94 1.94 Standard Equipment on BB100H and All Bimini Buddy Models • Factory Assembled • Deluxe Painted Cover with slots for wall mounting • Hydraulic Separator with: • Boiler, heating system, expansion tank and air elimination connections. BB100C includes standard equipment as well as: • Brazed Plate Heat Exchanger for domestic hot water • 120 volt Three Way Zone Valve and Flow Switch for domestic hot water priority BB100I includes standard equipment as well as: • 120 volt Three Way Zone Valve for domestic hot water priority • Indirect Water Heater connections (1" copper) CrownBofer.coM PHILADELPHIA, PA BB100 - 12/10 - 5M PN 980099...

Эта инструкция также подходит к моделям:
Водонагреватели - BB100C (920.29 kb)
Водонагреватели - BB100I (920.29 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории