Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Crown, модель AWI195

Производитель: Crown
Размер: 1003.72 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


5.0 11.0 Max. 14.0 13.0 If the line pressure falls outside of these limits, find and correct the cause of the problem before proceeding further. c) Connect a manometer to the manifold (outlet) pressure tap on the gas valve (see Figures 24 and 25). d) Read the manifold pressure. It should be set at: Natural Gas LP Gas Manifold Press. (inches w.c.) 3.5 10.0 e) If a manifold pressure adjustment is needed, make the adjustment by turning the regulator (see Figures 24 and 25) screw clockwise to raise the pressure and counter clockwise to reduce the pressure. If a manifold pressure adjustment is made, recheck the line pressure to be certain that it is still within acceptable limits. Replace the cover screw on the regulator. 16) Test thermostat operation while the boiler is running. Turn the thermostat to the lowest setting. Circulator should stop running. For standing pilot boiler models, pilot burner should remain lit but the main burners should stop firing. For intermittent ignition boiler models both pilot burner and main burners should stop firing. Raise the thermostat back to the highest setting. Circulator should restart. The main burners( for standing pilot boiler models) or pilot burner and main burners (for intermittent ignition boiler models) should relight. 17) Verify high limit operation. Allow the boiler water temperature to increase to hi limit setting. Circulator should continue running. For standing pilot boiler models, pilot burner should remain lit but the main burners should stop firing. For intermittent ignition boiler models both pilot burner and main burners should stop firing. 18) Allow the boiler water temperature to drop below high limit setting. 19) The main burners (for standing pilot boiler models) or pilot burner and main burners (for intermittent ignition boiler models) should relight. 22 20) After the boiler has operated for approximately 30 minutes, check the boiler and heating system piping for leaks. Repair any leaks found at once. 20) After the boiler has operated for approximately 30 minutes, check the boiler and heating system piping for leaks. Repair any leaks found at once. FIGURE 20: STANDING PILOT BURNER FLAME FIGURE 21: INTERMITTENT IGNITION PILOT BURNER FLAME FIGURE 22: MAIN BURNER FLAME - 1” BURNERS FIGURE 23: MAIN BURNER FLAME - 50mm (“HIGH ALTITUDE”) BURNERS 23 G WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 1. STOP! Read the safety information above onthis label. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. Remove front access panel. 5. Rotate the gas control knob clockwise to OFF. RESET BUTTON GAS INLET GAS CONTROL KNOB (SHOWN IN “ON” POSITION) GAS OUTLET GAS VALVE -TOP VIEW 6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety inform- ation above on this label. If you don’t smell gas, go to the next step. 7.Find pilot -follow metal pilottube from gas control to pilot burner. PILOT THERMO BURNER COUPLE If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS 8. Turn Knob on gas control counterclockwise to “PILOT”. 9. Push down and hold the red reset button while you light pilot burner with a match. After about one minute, release reset button. Pilot should remain lit. If it goes out, turn gas control knob clockwise to OFF. To relight, repeat steps 5-9. If button does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 10. After pilot remains lit when red reset button is released, turn gas control knob counterclockwise to ON. 11. Replace front access panel. 12. Turn on all electric power to the appliance. 13. Set thermostat to desired setting. TO...

Эта инструкция также подходит к моделям:
Водонагреватели - AWI037 (1003.72 kb)
Водонагреватели - AWI061 (1003.72 kb)
Водонагреватели - AWI095 (1003.72 kb)
Водонагреватели - AWI128 (1003.72 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории