|
Фрагмент инструкции
Each Alpine is hydro- tested and fire-tested in order to deliver safety, efficiency, durability and low emissions. Long Lasting Comfort Durable, efficient stainless steel heat exchanger maximizes heat transfer Burnham Alliance SL™ Indirect-firedWaterHeatersThe Alliance SL water heaters are designed with an effective hydrastone lining that offers superior corrosion resistance and outstanding performance in a wide variety of water conditions. Water heaters are available in five sizes and come with a unique 10/2/1 warranty – 10 years on the tank and coil, 2 years labor and 1 year on parts. Venting Easy To Move and Install Jacket sides are equipped with flush mounted carry handles. Jacket bottom features nylon glides An optional European-standard Polyproplyene Concentric Vent System is also available. The Alpine can also be vented with an optional two pipe system using stainless steel (AL29-4C) vent matierial. Alpine comes standard with a CPVC/PVC vent kit. This ETL-approved material consists of a 30” CPVC starter pipe and one 90° CPVC elbow. ALSO AVAILABLE Alpine Specifications ModelNo. Input(MBH) Output(MBH) NetI=B=R(MBH) AFUE(%) BoilerWaterVolume(gallons) HeatTrans. Area(sq.ft.) ShippingWeight(pounds) MinimumMaximumto2kft.2-7kft.0-7kft. ALP080 16 27 80 73 63 95 0.6 0.6 137 ALP105 21 35 105 96 83 95 0.7 0.7 155 ALP150 30 50 150 137 119 95 1.3 1.3 182 ALP210 42 70 210 193 168 95 1.7 1.7 206 ALP285 57 57 285 263 229 95 2.4 2.4 256 ALP399 80 80 399 377* 328 94.1/94.5** 3.4 3.4 304 ALP500 – Call for product availability and additional information – NOTES: DOE Heating Capacity (ALP080 through ALP285); Gross Output (ALP399) ** Thermal/combustion efficiency *Gross output Maximum Working Pressure - Water: ALP080-285=30PSI; ALP399=50PSI; 80PSI optional on all models Maximum Allowable Temperature = 210. F Boilers shipped set for natural gas; field adjustment for LP (see instruction manual) For elevations above 2000 feet, reduce ratings four percent (4%) per 1000 feet above sea level Alpine Dimensions Model No. A (in.) B (in.) C (in.) D (in.) E (in.) F (in.) G (in.) H (in.) J (in.) L (in.) M (in.) O (in.) P (in.) Q (in.) ALP080 12-9/16 5-5/8 7-5/16 9-5/16 5-15/16 1/2 1 1 * 8 32-3/16 16-11/16 12-1/2 4-3/4 ALP105 14 5-13/16 7-5/16 10-3/4 5-15/16 1/2 1 1 * 8 32-3/16 16-11/16 12-1/2 4-3/4 ALP150 19-11/16 5-13/16 7-5/16 16-7/16 5-15/16 1/2 1 1 * 8 32-3/16 16-11/16 12-1/2 4-3/4 ALP210 23-15/16 5-13/16 7-5/16 17-1/8 5-15/16 1/2 1 1 * 8 32-3/16 16-11/16 12-1/2 4-3/4 ALP285 21-13/16 7-5/16 14-1/8 18 12-1/4 3/4 1-1/4 1-1/4 * 8-5/16 43-7/16 17-5/16 12-3/16 4-3/4 ALP399 28-7/8 6-3/16 13-1/16 23-3/4 15-13/16 1 1-1/2 1-1/2 * 8-5/16 43-7/16 17-5/16 12-3/16 4-3/4 *Factory provided socket end compression pipe joining clamp for 3/4” schedule 40 PVC pipe Alpine Intake / Vent Sizes Model No. Intake Size Vent Size Max Length ALP080 3” 3” 60’ ALP105 3” 3’ 60’ ALP150 4” 3” 60’ ALP210 4” 3” 60’ ALP285 4” 4” 60’ ALP399 4” 4” 60’ Max length in equivalent feet for each run is 60 equivalent feet of intake & 60 equivalent feet vent length Maximum Vent Lengths Alpine16-11/16” ALLow Voltage Knockouts (24V) Line Voltage Knockouts (115V) One handle on ALP80 & 105, Two handles on all other models G(Return tapping) F(Gas valve inlet) H(Supply tapping) 3/4” FPT relief/drain tapping J(Condensate trap drain) MNOPDCEBQ # of 90° Elbows 2 4 6 8 10 12 Combined Intake/Vent - Feet of Pipe 110’ 100’ 90’ 80’ 70’ 60’ NOTE: Snorkels are approved for use with PVC venting. Intake & vent lengths combined. 90° = 5 equivalent feet. Terminals do not count towards vent feet length © 2008 U.S. Boiler Company, Inc. - Lancaster, PA Phone: 1-888-432-8887 Printed in the U.S.A. Pub. HYDL04081-25Ms ...
Эта инструкция также подходит к моделям:Водонагреватели - Condensing Stainless Steel (593.83 kb)