(C) 11 17 22 26 33 39 44 50 56 61 67 72 78 Model BTUH (KW) Rise (F) 20 30 40 50 60 70 80 90 100 110 120 130 140 HW-300 300,000 LPH 5,505 3,670 2,753 2,202 1,835 1,573 1,376 1,223 1,001 1,001 918 847 786 (88) GPH 1,455 970 727 582 485 416 364 323 291 264 242 224 20B HW-399 399,000 LPH 7,322 4,882 3,661 2,929 2,441 2,092 1,831 1,627 1,464 1,331 1,220 1,127 1,046 (116) GPH 1,935 1,290 967 774 645 553 484 430 387 352 322 298 276 HW-420 420,000 LPH 7,708 5,138 3,854 3,083 2,569 2,202 1,927 1,713 1,542 1,401 1,285 1,186 1,101 (123) GPH 2,036 1,358 1,018 815 679 582 509 453 407 370 339 313 291 HW-520 520,000 LPH 9,543 6,362 4,771 3,817 3,181 2,727 2,386 2,121 1,909 1,735 1,590 1,468 1,363 (152) GPH 2,521 1,681 1,261 1,008 840 720 630 560 504 458 420 388 360 HW-610 610,000 LPH 11,194 7,463 5,597 4,478 3,731 3,198 2,799 2,488 2,239 2,035 1,866 1,722 1,599 (179) GPH 2,958 1,972 1,479 1,183 9B6 845 739 657 592 538 493 455 423 Recovery capacity ratings are heater performance at an assigned 76% thermal efficiency. Actual recoveries are higher. NOTE: To compensate for the effects of high altitude areas above 2.000 feet (610m), input and output rating should be reduced approximately 4% for each 1,000 feet (305m) above sea level. SUGGESTED SPECIFICATIONS Boiler(s) for hot water supply purposes shall be Model(s) No._as manufactured by A. O. Smith or an approved equal. Boiler(s) shall be gas-fired, and design certified by the Canadian Gas Association or an approved/accredited independent rating laboratory, capable of supplying_GPH (LPH) at 100°F (56°C) temperature rise equipped to burn_gas, with input rating of_BTUH(KW)/hr. and bearing the ASME code symbol. Boiler(s) shall be up flow type having all non-ferrous waterways, and employing a copper finned heat exchanger and a tightly wound copper coil combustion chamber with 160 psi (1100 kPa) working pressure rating. Boiler(s) shall be equipped with an electric gas valve of the step-opening type, an adjustable limit control which will break the electric circuit on temperature rise, intermittent ignition with one (1) second shutdown in the event of pilot flame failure (propane models equipped with standing pilots), a gas pressure regulator properly set for the gas to be supplied, and a coil limit switch for shut off In event of excessive water temperature, a thermal balancer, a certified draft diverter and a fully illustrated instruction manual. Certified for combustible flooring. Outer jacket shall be of baked enamel finish. The coil, heat exchanger and burner shall have a five year limited warranty as outlined in the written warranty. A. O. Smith Enterprises Ltd. El Paso, Texas Water Products Company McBee, South Carolina A Subsidiary of A. O. Smith Corporation Seattle, Washington Stratford, Ontario Veldhoven, The Netherlands A. O. Smith Corporation reserves the right to make product changes or improvements at any time without notice. A 012.0C ©A. O. Smith Corp., 1996 Printed in U.S.A....

Эта инструкция также подходит к моделям:
Водонагреватели - HW 300 THRU HW 610 (166.38 kb)
Водонагреватели - HW 300 THRU HW 610 (166.38 kb)
Водонагреватели - HW 300 THRU HW 610 (166.38 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории