Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Bradford-White Corp, модель 103-B

Производитель: Bradford-White Corp
Размер: 400.64 kb
Название файла: 103b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271. Defender Safety System®, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation. 103-B-0508-A Residential Direct Vent Water Heater Direct Vent Energy Saver Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency NATURAL GAS AND LIQUID PROPANE GAS Model Number Capacity Nat. LP Recovery at 90°F Rise* Nat. Nat. LP LP A Floor to Center Line of B Jacket Dia. C Vent Size D Floor to T&P Conn. E Floor to Gas Conn. F Floor to Top of Heater H Floor to Water Conn. K Depth Approx. Shipping Weight U.S. Gal. Imp. Gal. BTU/Hr. Input BTU/Hr. Input U.S. GPH Imp. GPH U.S. GPH Imp. GPH Vent in. in. in. in. in. in. in. in. lbs. DS1-40S6FBN 40 33 38,000 36,000 41 34 39 32 631/4 min. 20 3-5 431/2 147/8 493/4 503/4 299/16 162 DS1-50S6FBN 50 42 42,000 40,000 45 37 43 36 721/4 min. 20 3-5 521/4 147/8 583/4 593/4 299/16 181 Model Number Capacity Recovery at 50°C Rise* A Floor to Center B Jacket Dia. C Vent Size D Floor to T&P E Floor to Gas F Floor to Top H Floor to Water K Depth Approx. Shipping Weight Nat. kW LP kW LP Liters/ Nat. Liters/ Line of Vent Conn. Conn. of Heater Conn. Liters Input Input HourHour mm. mm. mm. mm. mm. mm. mm. mm. kg. DS1-40S6FBN 151 11.1 10.5 148155 1607 508 76-127 1105 378 1264 1289 737 73 DS1-50S6FBN 189 12.3 11.7 163170 1835 508 76-127 1327 378 1492 1518 737 82 All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX". For 10 year models, change suffix from “6” to “10”. *Based on manufacturers rated recovery efficiency. The water heater is shipped with a standard vent kit. Vent Kit components are: 3" Vent tube and elbow, 5" Air Intake tube and elbow, Vent terminal and hardware, Inner and Outer wall terminal mounting flange, RTV silicone sealant. Length “X” 133/4" to 143/16" 15" to 1711/16" 221/4" to 323/16" 36" to 557/8" 585/16" to 1045/16" Height “Y” 10" Order Kit A Order Kit B No Add’l. Kit Req’d. Order Kit C Order Kit D 143/4" to 1511/16" Order (2) Kit A Order Kit A & B Order Kit A Order Kit A & C Order Kit A & D 161/2" to 193/16" Order Kit A Order (2) Kit B Order Kit B Order Kit B & C Order Kit B & D 233/4" to 3311/16" Order Kit A Order Kit B Order Kit C Order (2) Kit C Order Kit D 371/2" to 573/8" Order Kit C & A Order Kit C & B Order (2) Kit C Order (3) Kit C Order Kit C & D 5913/16" to 10513/16" Order Kit D & A Order Kit D & B Order Kit D Order Kit D & C Order (2) Kit D The Vent tube and Air Intake tube provided with the heater telescopes from 133.4" to 2311.16". The kits found in the bold frame are needed in addition to the vent and air intake tube provided with the water heater (utilizes the vent tube provided). The kits found outside the bold frame do not utilize the vent tube provided with the standard vent kit. For vent distances not found in the selection chart above, please contact the Product Department for sizing recommendations. Optional vent kit : Kit “A” Telescopes from 43.4" to 511.16" Part No. 243-41260-00 Kit “B” Telescopes from 61.2" to 93.16" Part No. 243-41331-00 Kit “C” Telescopes from 133.4" to 2311.16" Part No. 243-41029-00 Kit “D” Telescopes from 4913.16" to 9513.16" Part No. 243-41424-00 Horizontal Vent Termination Only. F Please specify part number when ordering optional vent kit. For additional information, please reference the installation instructions. XABEHY73/4" KD Meets NAECA Requirements General All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3.4" NPT (19mm) on 8" (203mm) centers. All gas connections 1.2" (13mm). All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. Ambler, PA For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 . Fax 215-641-1670 / Technical Support 800-334-3393 . Fax 269-795-1089 . Warranty 800-531-2111 . Fax 269-795-1089 International: Telephone 215-641-9400 . Telefax 215-641-9750 / Sales / Technical Support 866-690-0961 / 905-238-0100 lFax 905-238-0105 / ©2008, Bradford White Corporation. All rights reserved. 103-B-0508-A Printed in U.S.A. ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории