Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Bradley Smoker, модель S19-690LHS

Производитель: Bradley Smoker
Размер: 44.38 kb
Название файла: 3d5182b7-5426-4afe-b419-ab2cc359a682.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Connect the heat trace cable to the junction box. • Slide the jacket up the side of the tank and pull the drawstring at the top of the jacket. • Place the junction box in the pocket on the inside of the jacket. Figure 1 Back View Bradley Corporation • 215-084 Rev. L; EN 02-586 10-Gallon Tank with Eye Wash and Optional Heater Jacket S19-690LHS, S19-690H Installation Instructions Installation Instructions continued . . . Step 2: Fill tank and pressurize 1. If the tank is pressurized, relieve the tank pressure by pulling up on the relief tank tab in the center of the cover until the pressure gauge reads “0.” IMPORTANT: DO NOT open the cover until the pressure gauge reads “0”! 2. Open the tank by pulling up on the wire handle located on top of the Quicklock cover. Push down, rotate and remove. Fill the container with 7 gallons of potable water. Replace the cover. 3. Pressurize the tank to 95 PSI by applying air pressure to the valve located beneath the pressure gauge. NOTE: Relief valve is designed to automatically vent at 100-130 PSI to prevent the tank from over- pressurizing. Step 3: Flush tank 1. Discharge the water through the eye wash for at least five minutes to flush the system. 2. Refill the tank and pressurize as explained in Step 2 outlined above. NOTE: Let unit stand for one hour. If there is a noticeable pressure drop, repressurize back to 95 PSI and let stand for one hour. If problems persist, consult the Troubleshooting guide found on page 5. NOTE: This unit will provide at least 15 minutes of cleansing action. Take the injured person immediately to a normal emergency station for additional cleansing and treatment. 3. FOR OPTIONAL HEATER JACKET: Plug the jacket’s electrical cord into an electric outlet. Bradley Corporation • 215-084 Rev. L; EN 02-586 10-Gallon Tank with Eye Wash and Optional Heater Jacket Installation Instructions S19-690LHS, S19-690H Maintenance Instructions WARNING: Water preservatives protect potable water from bacteria, fungi and algae growth for up to four months. If a water preservative is not used with this eye wash, it is recommended that the tank be cleaned weekly or as often as needed. Infection, loss of vision or other serious injury may result from misuse of this eye wash. DO NOT use expired, cloudy, colored or contaminated solution. DO NOT open preservative bottle if safety seal is broken. DO NOT save unused solution. Step 1: Inspect eye wash unit 1. Visually inspect the pressure gauge weekly to ensure the unit is maintaining the proper pressure. If the unit is not working properly, remove it from the hazard area immediately and refer to the troubleshooting instructions. For further assistance, contact the Bradley Corporation. Step 2: Clean eye wash unit When using potable water only: 1. Empty the tank any time from once per week to once per month, depending on the quality of your water supply. The manufacturer is not responsible for variations in the water supply. 2. Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 3. Refill the eye wash tank following the procedure outlined in Step 2 found on page 4. When using potable water and water preservative (recommended): 1. Empty the tank at least once every 120 days. 2. Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 3. Refill the eye wash tank with potable water and the contents of an 8-ounce bottle of water preservative (refer to the procedure outlined in Step 2 found on page 4). • To order potable water preservative, contact your Bradley representative or local distributor and ask for part number S19-865. Troubleshooting 1. If pressure relief valve relieves prior to the required pressure, do the following (when in the unpressurized condition): • Tighten the valve completely into the cap by turning the gray hex head portion of the pressure relief valve clockwise. Do not use a wrench. • Pull up on the relief valve ring and ensure that the ring is not preventing the valve from closing completely. Push on the center pin of the relief valve to ensure that it is completely closed. Repressurize tank to required pressure. This may have to be done several times to get the valve to seat completely. 2. If the pressurized tank loses pressure over time, check the connections with diluted liquid dish soap or children’s bubbles to identify the leak location. Tighten the connection slightly and test again. Bradley Corporation • 215-084 Rev. L; EN 02-586 10-Gallon Tank with Eye Wash and Optional Heater Jacket S19-690LHS, S19-690H Installation Instructions Assembly of Components Figure 2 Parts List Item Part No. Qty Description Item Part No. Qty Description 1 S27-252 1 TANK – 10 GALLON 9 107-371 2 TETHERED DUST COVER 2 153-429 1 ADAPTER 10 269-1671 1 PIPE WRAP 3 153-217 1 ADAPTER 11 261-007B 1 HEATER BELT, 4 " 4 169-786 1 PRESSURE GAUGE 12 S83-167 1 JUNCTION BOX ASSEMBLY 5 S27-161 1 TANK VALVE ASSY. 13 230-022 1 POWER SUPPLY C...

Эта инструкция также подходит к моделям:
Водонагреватели - S19-690H (44.38 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории