Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Canon, модель VB-C50i/VB-C50iR

Производитель: Canon
Размер: 9.4 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


Enter a value between 1 and 65535. The default setting is 80. 2 “Global Address for Web Pages” If a private address has been set in the VB-C50i/VB-C50iR and you want to use the router’s NAT functions to have a fixed global address for the VB-C50i/VB-C50iR (> P.5-26), enter a global address here, and this will let you view sample pages (> P.5-6). If “IP Address” is selected, enter the IP address specified in “IP Address”. If “Host Name” is selected, the host name specified in “DNS” in “Miscellaneous” is used. Perform any necessary settings in “DNS” (> P.3-26). Basic Settings 3-17 Setting Up the HTTP, Camera and Audio Servers (Server) Camera Server 1 3 4 5 6 7 1 “Video Transmission Port” Set the TCP port number for the video transmission protocol. Enter a value between 1 and 65535. The default setting is 65310. Normally, there is no need to change this setting. 2 “Camera Control Port” Set the TCP port number for the camera control protocol. Enter a value between 1 and 65535. The default setting is 65311. Normally, there is no need to change this setting. 3 “Maximum Frame Rate (fps)” Set the maximum number of frames captured per second. The maximum frame rate is 30.0 fps (NTSC)/25.0 fps (PAL) and enter a number between 0.1 and 30.0 (NTSC)/25.0 (PAL). *Please refer to P.1-11 to confirm whether your VB-C50i/VB-C50iR is PAL model or NTSC model. 4 “Maximum Transmission Rate (Mbps)” Set the upper limit of the volume of data to be transmitted in one second. This function is used to reduce the load on the network. The maximum is 10Mbps and enter an integer of 0 to 10. 0 means unlimited. 5 “Control Queue Length” Set the length of the queue when multiple clients are waiting for control privileges under the viewer. Enter a value between 0 and 50. The maximum number is 50. When set to “0”, only the Admin Viewer is permitted to control the camera. 6 “Camera Control Time (sec.)” Set the maximum time for which camera control privileges can be maintained under the viewer. Enter a value between 1 and 3600. 7 “Camera Stabilization Time (msec.)” When the GetStillImage command (> P.5-25) has been requested, this setting specifies the delay to allow the camera to stabilize before a still picture is captured. Enter a value between 0 and 10000. The maximum delay is 10000 milliseconds. Audio Server 1-5, 8 are only displayed with two particular models (> P.iii). 12345678 1 “Audio Transmission” Set “Audio Transmission” to “Used” to send audio to the Viewer for PC or Admin Viewer, that is input into the microphone connected to the Multi-Terminal Module (> P.1-12). 2 “Input Volume” Set the volume of the input audio in a range from 1-100. The larger the numeric value, the louder the audio will be. 3 “Voice Activity Detection” Set “Voice Activity Detection” to “ON” to pause the transmission of audio data when the server does not detect any valid audio data from the microphone. Doing this reduces the network bandwidth that you are using. 4 “Noise Canceller” Set “Noise Canceller” to “ON” to cancel noise in the audio. 5 “Slope Filter” Set “Slope Filter” to “ON” to cancel any low pitch noise such as outdoor wind sound. Audio Transmission • Input Volume • Voice Activity Detection • Noise Canceller • Slope Filter Basic Settings 3-19 6 “Audio Reception” Set “Audio Reception” to “Used” to receive audio which has been sent from the Admin Viewer and output to the speaker with amp connected to the Multi-Terminal Module (> P.1-12). 7 “Output Volume” Set the volume of output audio in a range from 1-100. The larger the numeric value, the louder the audio will be. 8 “Echo Canceller” Set “Echo Canceller” to “ON” to prevent acoustic echo when transmitting and receiving audio from the speaker with amp and microphone connected to the Multi-Terminal Module (> P.112). Audio Reception • Output Volume • Echo Canceller Note .Use the Multi-Terminal Module (>P.1-12) when connecting a microphone* or speaker to the VB-C50i/VB-C50iR. .Setting “Noise Canceller”, “Slope Filter”, and “Echo Canceller” to “ON” may have an effect on the audio volume and quality. Set “ON” or “OFF” according to the environment where you install and how you use the VB-C50i/VB-C50iR.* .When sending or receiving audio*, please read carefully “Usage Notice of Audio” (> P.iii). .Use the VB Administration Tools to view or modify the settings for Audio Playback and recording*. * Only available with two particular models (> P.iii) ) Basic Settings You can perform the following settings with Access Control. .Authorized User Account: Register users who may connect to the VB-C50i/VB-C50iR. .Authorized/Restricted Host Specification: Control whether a specific host is to have access or not. When you have made changes to the settings, click the “OK” button to return to the Settings Title Page. If you do not make any changes, click the “Cancel” button. Authorized User Account 1234 1 “User List” Only users registered in this list are permitted to connect to the VB-C50i/VB-C50iR. You can register a maximum o...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории