Фрагмент инструкции


Dynamic range of 40 dB. (3) Various External Sync Functions, including Gen-Lock (4) Electronic Shutter Function 2. Signal-to-noise ratio of 50 dB 3. Minimum illumination of 0.08 lux (0.008 footcandle) with F 1.4 lenses. 4. Minimum illumination of 0.02 lux (0.002 footcandle) with Panasonic aspherical high speed (F0.75) lenses. 5. 570 lines of horizontal resolution ture elements), and digital signal processing LSI's. This model offers cutting-edge technology for advanced video surveillance. 6. High quality picture: (a) 2H type vertical enhancer for greater picture sharpness (b) Minimum of aliasing on fine objects (c) Expanded dynamic range by use of knee circuit (d) Highlight aperture correction for greater picture detail of bright object 7. Ability to shoot indoor scenes with fixed iris lens by use of Electronic Light Control (ELC) function. 8. Selectable electronic sensitivity enhancing modes including : AUTO, MANUAL and OFF 9. Built in Digital Motion Detector PRECAUTIONS 1. Do not attempt to disassemble the camera. To prevent electric shock, do not remove screws or covers. There are no user serviceable parts inside. Ask a qualified service person for servicing. 2. Handle the camera with care. Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage. 3. Do not expose the camera to rain or moisture, or try to operate it in wet areas. Turn the power off immediately and ask a qualified service person for servicing. Moisture can damage the camera and also create the danger of electric shock. 4. Do not use strong or abrasive detergents when cleaning the camera body. Use a dry cloth to clean the camera when dirty. In case the dirt is hard to remove, use a mild detergent and wipe gently. 5. Clean the CCD faceplate with care. Do not clean the CCD with strong or abrasive detergents. Use lens tissue or a cotton tipped applicator and ethanol. 6. Never face the camera towards the sun. Do not aim the camera at bright objects. Whether the camera is in use or not, never aim it at the sun or other extremely bright objects. Otherwise, blooming or smear may be caused. 7. Do not operate the camera beyond the specified temperature, humidity or power source ratings. Use the camera under conditions where tempera- • ture is between -10°C - +50°C (14°F - 122°F), and humidity is below 90%. The input power source is 120V AC 60Hz for WV-BP550 and DC 12V/AC 24V for WV-BP554. Caution: To prevent fire or electric shock hazard, a UL listed wire (VW~1, style 1007) should be used for DC 12V or AC 24V Input Terminals. MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS -4- (D Auto Iris Lens Connector This connector is used to connect with the auto iris lens by a 4-pin male connector that is supplied as a standard accessory (Part No. YFE4191J100). d) Flange-back Adjusting Ring This ring is used to adjust the back focal length or picture focus. Rotate this ring clockwise for a C-mount lens or counterclockwise for a CS-mount lens. d) Lens (Option) (D Camera Mounting Screw Hole This hole is used to mount the camera onto a mounting bracket. (D Down Button () This button is used to move the cursor downward. It is also used to select items in the CAM SET UP menu. (D Right Button () This button is used to move the cursor to the right. It is also selects the mode and can be used to adjust some levels. (7) Left Button ( ) This button is used to move the cursor to the left. It also selects the mode and can be used to adjust some levels. ® Up Button (i®i) This button is used to move the cursor upward. It is also used to select items in the CAM SET UP menu. (9) Set Button ([=]) This button is used to activate an item selected in the CAM SET UP menu. © Gen-lock Termination Switch (Hi-Z, G/L 75£i) Set this switch to Hi-2 when a gen-lock video input signal is looped through. In all other cases, set this switch to 75ii. (0) Power indicator This indicator lights up when the power of this camera is on. © Gen-lock Input Connector (GEN-LOCK) This connector is used to connect an external system for synchronization. Video Output Connector (VIDEO OUT) This connector is used to connect with the VIDEO IN connector of the monitor. 10' Power Cord Socket This socket is used to connect the power cord (supplied as a standard accessory). © Alarm Output Terminal (ALARM OUT/GND) This terminal is used to connect to the ALARM INPUT connector (terminal) of an external equipment. When this camera detects motion, the alarm output signal is supplied to the connected external equipment. (Open collector output: 16V DC 100mA max.) © AC/DC Compatible Input Terminal (DC 12V IN/AC 24V IN) This terminal is for connecting the 12 V DC or 24 V AC power supply cord. Cautions: 1. Connect to 12V DC (10.5V-16V) or 24V AC (19.5V-28V) class 2 power supply only. Make sure to connect the grounding lead to the GND terminal when the power is supplied from a 24V AC power source. 2....


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории