Производитель: Humax
Размер: 1.67 mb
Название файла: UM-CXPVR9200C_300GB.pdf
|
Фрагмент инструкции
5. When completing channel search and deleting unnecessary channels, select Save and press the OK button to save the results. GB 71 10. Installation 10.5 Default Setting Default setting restores the product to the default settings. Warning: Please note that once you perform default setting, all data such as channel list and user configured data are deleted, no information on the HDD will be lost. 1. Press the MENU button. 2. Select Installation using the button and press the OK or button. 3. Enter the password using the NUMERIC(0-9) buttons. 4. Select Default Setting using the button and press the OK or button. 5. Select Yes and press the OK button to restore all setting to factory default. Select No and press the OK or BACK button to return to the previous menu. 6. Confirm again to start loading default setting. Enter the password using the NUMERIC(0-9) buttons to perform restoring. 7. When completing the default setting, press the OK button to automatically run the installation wizard. For detailed information about the installation wizard, refer to Chapter 3. Installation Wizard. Note: The default password is 0000. If you have forgotten the password, please contact your local product distributor. GB 72 11. Software Update In order to maintain proper performance of the product, it is essential to have the most up-to-date software. Visit the Humax website to check the latest news and newly released software versions. It is recommended that you periodically check for the availability of software update. 11.1 OTA (Over the Air) OTA, an abbreviation of Over–the-Air, is a standard for the transmission of software through a broadcast system. The manufacturers reserve the right to decide when and where an update is made available. The new software version is then downloaded via cable. The software update via cable will only occur under the following circumstances. 1. The equipment should have appropriate loader software. Caution: Please note that if normal loader software is not equipped, the product may not be updated or operate properly after software update. 2. The manufacturer transmits the software via cable. The new version of the software is generally detected automatically. Caution: • Please be careful to keep the power on and the power cord plugged in during software update. If the power is off during software update, fatal damage may be caused to the product. • Please be careful not to pull out the signal line (co-axial cable) during software update. Update may be interrupted and the product may not operate. Note: • Other functions will not activate while software update takes place. • It may take 5 ~10 minutes to update software. • Scheduling operation cannot work during software update. 1.Ifnewsoftwareisfoundwhenpoweringon 1. A message will be displayed to notify that new software is found. 2. Select Yes and press the OK button to update the software. 3. Starts downloading new software. Please wait until the update is completed. 4. When completing the software update, the equipment is automatically powered off and on again. GB 73 11. Software Update 11.2 Updating Software from Menu 1. Press the MENU button. 2. Select Installation using the button and press the OK or button. 3. Enter the password using the NUMERIC(0-9) buttons. 4. Select Software Update using the button and press the OK or button. Note: The default password is 0000. If you have forgotten the password, please contact your local product distributor. 1.AutomaticUpdate You can update software automatically. 1. Select Automatic Update using the button and press the OK or button. 2. Automatically search for new software. Select Cancel and press the OK button to finish search. 3. When detecting software update, the following result is displayed. If new software is not found by automatic update, use manual update. 4. Select Yes and press the OK button to start updating. Select No and press the OK button to return to the previous menu without updating. 5. When completing the software update, the product is automatically powered off and on again. GB 74 2.ManualUpdate You can perform manual update using know MUX information. 1. Select Manual Update using the button and press the OK or button. 2. Select Frequency using the button and press the OK or button. Select the frequency using the button and press the OK or button. Select User Define to enter the value directly. 3. Select Symbol Rate using the button and press the OK or button. Select the frequency using the button and press the OK or button. Select User Define to enter the value directly. 4. Select Search and press the OK button to search software. 5. Existing new software will show. If new software does not exist, press the OK button to return to the manual update menu. 6. Select Yes and press the OK button to start updating. Select No and press the OK button to return to the previous menu. 7. Performs software update. Please wait until it is completed. 8. Wh...